Plan Review Details - Permit 02091555
Plan Review Stops For Permit 02091555
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-04-07 Cont ID  
Sent By dpalmer Date 2003-04-07 Time 16:37 Rev Time 0.25
Received By dpalmer Date 2003-04-07 Time 16:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-03-31 Cont ID  
Sent By shernand Date 2003-04-07 Time 15:48 Rev Time 0.50
Received By btrobaug Date 2003-03-31 Time 11:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-02-14 Cont ID  
Sent By btrobaug Date 2003-02-14 Time 12:26 Rev Time 0.50
Received By btrobaug Date 2003-02-14 Time 12:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-10-16 Cont ID  
Sent By dpalmer Date 2002-10-16 Time 09:08 Rev Time 0.50
Received By dpalmer Date 2002-10-16 Time 09:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-07 Cont ID  
Sent By shernand Date 2003-04-07 Time 15:48 Rev Time 0.00
Received By shernand Date 2003-04-07 Time 15:48 Sent To E
Notes
2003-04-07 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-07 Cont ID  
Sent By btrobaug Date 2002-11-07 Time 11:22 Rev Time 0.00
Received By btrobaug Date 2002-11-07 Time 11:21 Sent To R
Notes
2002-11-07 00:00:00TO ROB MCDOUGAL./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-10-19 Cont ID  
Sent By hmoser Date 2002-10-19 Time 10:29 Rev Time 0.33
Received By hmoser Date 2002-10-19 Time 10:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-10-07 Cont ID  
Sent By jleech Date 2002-10-07 Time 19:19 Rev Time 0.25
Received By jleech Date 2002-10-07 Time 19:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-11-08 Cont ID  
Sent By rmcdouga Date 2002-11-08 Time 15:02 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-11-08 00:00:00PROVISO
  
 1) SUBMIT REVISED STORM PANEL SCHEDULE
 AND KEY PLAN WITH THE CORRECT OPENING
 SIZE SPECIFIED FOR (#13) THE FIXED
 GLASS WINDOW ASSEMBLY IN THE FAMILY
 ROOM.
  
 2) SUBMIT PRODUCT APPROVALS FOR THE
 FIXED GLASS WINDOWS ABOVE THE SH 1/2-36
 IN THE FAMILY ROOM WITH DESIGN PRESSURES
 OF -45.3 AND +34.4.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-10-29 Cont ID  
Sent By btrobaug Date 2002-11-07 Time 11:22 Rev Time 5.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-10-29 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) STRUCTURE IS LOCATEDIN AN "AO" FLOOD
 ZONE AN ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 3) ON SHEET A5 THERE IS A DETAIL TAG FOR
 1 ON A8. HOWEVER THERE IS NO SHEET A8.
 PLEASE CORRECT.
  
 4)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
 PLEASE INCLUDE ALL OF THIS REQUIRED
 INFORMATION ON THE PLANS.
  
 5) NUMBER 11 OF THE PLAN NOTES ON SHEET
 C1 STATES THAT HURRICANE PANELS ARE
 REQUIRED IN HVHZ AREA. THE CITY OF WPB
 IS NOT LOCATED IN A HIGH VELOCITY
 HURRICANE ZONE, HOWEVER, IMPACT
 PROTECTION IS REQUIRED. PLEASE REVISE.
  
 6)THE PLANS DO NOT INDICATE THE LOCATION
 OF THE ROOF DIAPHRAGM NAILING ZONES 1,2
 & 3 THAT ARE LISTED IN THE DIAPHRAGM
 SCHEDULE AND BRACING LEGEND ON A6.
  
 7) THERE IS NO TRUSS CONNECTOR SCHEDULE
 GIVEN TO CORRESPOND WITH THE CONNECTOR
 DESIGNATIONS ON A6.
  
 8)THE KEY PLAN AND INSTALLATION SCHEDULE
 FOR THE STORM PANELS LIST INCORRECT
 OPENING SIZES FOR #S 2,3 & 13. PLEASE
 CORRECT.
  
 9) THE GLASS BLOCK AT THE MASTER BATH
 TUB IS REQUIRED TO HAVE A MINIMUM
 UNIFORM FACE THICKNESS OF 0.25 INCH PER
 FBC 2405.2.1 AND 2405.2.2(5).
  
 10) THE FBC SEC.1707.4.4.2 REQUIRES
 WINDOW AND DOOR ASSEMBLIES WITH BUCKS
 LESS THAN 1-1/2" THICK TO BE ANCHORED
 THROUGH THE BUCK TO THE ROUGH OPENING
 SUBSTRATE.
  
 11) THE SITE SPECIFIC PRODUCT APPROVAL
 FORMS REQUIRE THE EMBOSSED SEAL OF THE
 DESIGNER OF RECORD IN ADDITION TO HIS
 SIGNATURE.
  
 12) THERE WAS NO SITE SPECIFIC PRODUCT
 APPROVAL FORM SUBMITTED WITH THE
 UNCLIPPED VERTICAL MULLION DRAWINGS.
  
 13) THE DIMENSIONS GIVEN IN THE DRAWINGS
 FOR THE DESIGNER WINDOWS DO NOT
 CORRESPOND WITH SEVERAL OF THE FIXED
 GLASS WINDOWS SHOWN ON THE PLANS. PLEASE
 REVIEW AND REVISE FOR THE SIZES ON THE
 PLANS. CHECK TO BE SURE THAT THE WIND-
 LOAD PRESSURES ARE ADEQUATE.
  
 14) PROVIDE PRODUCT APPROVAL FOR
 HORIZONTAL STRUCTURAL MULLIONS.
  
 15) PLEASE INSERT REVISED PAGES INTO THE
 PLANS. RETURN OLD PLANS TO EXPEDIATE
 PLAN REVIEW.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-10-01 Cont ID  
Sent By sgraham Date 2002-10-01 Time 11:04 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***