Plan Review Details - Permit 02091413
Plan Review Stops For Permit 02091413
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-10-04 Cont ID  
Sent By btrobaug Date 2002-10-01 Time 07:55 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-17 Cont ID  
Sent By btrobaug Date 2002-10-17 Time 15:38 Rev Time 0.50
Received By btrobaug Date   Time   Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-10-01 Cont ID  
Sent By btrobaug Date 2002-10-01 Time 07:53 Rev Time 1.00
Received By btrobaug Date 2002-10-01 Time 07:22 Sent To B
Notes
2002-10-01 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION AND MAKE ANY NECESSARY
 CHANGES ON THE PLANS.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2} THE RISER DIAGRAM SHOWS AN EXISTING
 METER BUT THE NOTE AT THE METER
 LOCATION INDICATE A NEW METER BEING
 RELOCATED,PLEASE CLARIFY.
  
 3} THE NOTE ON THE GROUNDING ELECTRODE
 SYSTEM IS UNACCEPTABLE FOR
 REVIEW.PLEASE PROVIDE DETAILS.
  
 4} THE NOTE ABOUT THE SERVICE CONDUIT
 BEING ROUTED IN THE CRAWL SPACE IS IN
 VIOLATION OF ARTICLE 230-6 NEC AND
 230-70(A) WEST PALM BEACH AMMENDMENTS.
 IN EITHER CASE A MAIN DISCONNECT WOULD
 BE REQUIRED PER 225-31 & 225-32 NEC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL;
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT.8392

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-10-17 Cont ID  
Sent By pkrauss Date 2002-10-17 Time 16:37 Rev Time 0.30
Received By pkrauss Date 2002-10-17 Time 16:37 Sent To  
Notes
2002-10-17 00:00:00MECH PERMIT 02091417

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-09-28 Cont ID  
Sent By btrobaug Date 2002-10-17 Time 15:38 Rev Time 0.50
Received By hmoser Date 2002-09-28 Time 08:09 Sent To  
Notes
2002-09-28 00:00:00PLAN/DENIED
 1) REFER TO SECTION 601.4 FBC(M) 2001
 BALANCED RETURN AIR
 2) NO ENERGY CALCULATIONS
 3) SHOW LOCATION OF RETURN AIR
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390