Plan Review Stops For Permit 02091306 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
15 |
Status |
P |
Date |
2003-12-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-12-10 |
Time |
15:05 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2003-12-10 |
Time |
15:05 |
Sent To |
|
|
Notes |
2003-12-10 00:00:00 | REVISION GALLEY TO WORK ROOM. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
14 |
Status |
P |
Date |
2003-12-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-12-04 |
Time |
08:55 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
2003-12-04 |
Time |
08:55 |
Sent To |
|
|
Notes |
2003-12-04 00:00:00 | SUBMITTALS OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
13 |
Status |
F |
Date |
2003-11-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-11-26 |
Time |
08:01 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2003-11-26 |
Time |
08:01 |
Sent To |
|
|
Notes |
2003-11-26 00:00:00 | REVISIONS: | | ACTION: DENIED | | (3) SETS OF ALL CORRESPONDANCE REQUIRED | | FL S. S. 553.71(7) " THRESHOLD | | BUILDING" MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT IN | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN | | CY CLASSIFICATION AS DEINED IN THE | | FLORIDA BUILDING CODE WHICH EXCEEDS | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | CONTENT OF GREATER THAN 500 PERSONS. | | 105.13.1 THE ENFORCING AGENCY SHALL | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | BUILDING PURSUANT TO A STRUCTURAL INSPEC | | TION PLAN PREPARED BY THE ENGINEER OF | | RECORD. THE STRUCTURAL INSPECTION PLAN | | MUST BE SUBMITTED TO THE ENFORCING AGEN- | | CY PRIOR TO THE ISSUANCE OF A BUILDING | | PERMIT FOR THE CONSTRUCTION OF A THRESH- | | OLD BUILDING. THE PURPOSE OF THE SRUCTUR | | AL INSPECTION PLAN IS TO PROVIDE SPECIF- | | IC INSPECTION PROCEDURES AND SCHEDULES | | SO THAT THE BUILDING CAN BE ADEQUATELY | | INSPECTED FOR COMPLIANCE WITH THE | | PERMITTED DOCUMENTS. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-10-23 |
Time |
07:52 |
Rev Time |
0.25 |
Received By |
jwitmer |
Date |
2003-10-23 |
Time |
07:52 |
Sent To |
|
|
Notes |
2003-10-23 00:00:00 | REVISION:FACIA DETAIL FSK-10. REVISION | | # 1 10/10/03OKJW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
P |
Date |
2003-10-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-10-20 |
Time |
17:24 |
Rev Time |
3.00 |
Received By |
jwitmer |
Date |
2003-10-20 |
Time |
17:24 |
Sent To |
|
|
Notes |
2003-10-20 00:00:00 | SUBMITTALS, SITE SPECIFIC PRODUCT | | APPROVAL DOORS, HURRICANE TEST LAB/ OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
F |
Date |
2003-10-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-10-09 |
Time |
13:35 |
Rev Time |
1.50 |
Received By |
jwitmer |
Date |
2003-10-09 |
Time |
13:35 |
Sent To |
|
|
Notes |
2003-10-09 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 N. AUSTRALIAN AV | | CONT: HEDRICK BROTHERS | | TEL: (561)662-8391 ROBIN LUNSFORI | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | PRODUCT APPROVALS: | | VISTA WALL | | ACTION: DENIED | | | | THE PREVIOUS REVIEW WAS FOR DOORS TESTED | | BY HURRICANE TESTING LAB. THE REPORT WAS | | ALSO TESTED FOR LARGE MISSLE IMPACT. | | THE RESUBMITTAL SUBMITTED, HAS THE | | SITE SPECIFIC CITY FORM, BUT MISSING THE | | ORIGINAL HURRICANE TESTING LAB REPORT | | FOR LARGE MISSLE TESTING. THE HURRICANE | | TESTING LAB REPORT PLUS THE SITE SPECI- | | FIC FORM ARE BOTH REQUIRED. | | 1606.4.1(1) TESTING FOR LARGE MISSLE | | IMPACT. 1707.4.1 DESIGN PRESSURES. | | THE DESIGN PROFESSIONAL OF RECORD | | SHALL SIGN/SEAL AND DATE THE RIGHT SIDE | | OF THE SITE SPECIFIC FORM. | | THE DESIGN PROFESSIONAL ALSO HAS THE | | OPTION OF A COVER LETTER WHICH THEY | | WOULD SIGN AND SEAL WITH THE SPECIAL | | INSTALLATION REQUIREMENTS. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
F |
Date |
2003-09-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-06 |
Time |
14:05 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2003-09-22 |
Time |
16:58 |
Sent To |
|
|
Notes |
2003-09-22 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 N. AUSTRALIAN AV | | CONT: HEDRICK BROTHERS | | TEL: (561)662-8391/ROBIN LUNSFORI | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | SHOP DRAWINGS | | ACTION: DENIED | | | | SITE SPECIFIC ENGINEERING (PRODUCT | | APPROVAL) REQUIRES THE WET SIGNATURE, | | DATE AND EMBOSSED SEAL OF THE ENGINEER | | CERTIFYING THE PRODUCT AND SIGNATURE | | AND SEAL OF THE DESIGN PROFESSIONAL | | OF RECORD. | | HURRICANE TESTING LAB REQUIRES SITE | | SPECIFIC TESTING, THE REQUIRED CITY FORM | | FOR PRODUCTS THAT DO NOT HAVE SBCCI OR | | DADE COUNTY TESTING IS ATTACHED. THE ENG | | INEER FOR THE TESTING LAB FILLS OUT THE | | LEFT SIDE OF THE FORM, THE DESIGN | | PROFESSIONAL FOR THE SITE FILES OUT THE | | RIGHT SIDE BOTH SEALING THEIR INFORMA- | | TION PROVIDED. THE ARCHITECT OF RECORD | | OR THE STRUCTURAL ENGINEER MAY FILL OUT | | THE RIGHT SIDE OF THE FORM. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2003-08-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-22 |
Time |
14:23 |
Rev Time |
2.25 |
Received By |
jwitmer |
Date |
2003-08-05 |
Time |
11:13 |
Sent To |
|
|
Notes |
2003-08-05 00:00:00 | TRUSS REVIEW OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2003-07-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-31 |
Time |
11:33 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2003-07-14 |
Time |
10:35 |
Sent To |
|
|
Notes |
2003-07-14 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 AUSTRALIAN AV | | CONT: HEDRICK BROTHERS | | TEL: (561)662-8391 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | ACTION: DENIED | | | | SHOP DRAWINGS: TO BE REVIEWED BY THE | | DESIGN PROFESSIONAL STAMPED REVIEWED OR | | REVIEWED WITH CORRECTIONS BEFORE SUB- | | MITTING TO THE BUILDING DEPARTMENT. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2003-05-16 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-07 |
Time |
15:48 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2003-05-16 |
Time |
07:30 |
Sent To |
|
|
Notes |
2003-05-16 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 N AUSTRALIAN AVE | | CONT: HEDRICK BROTHERS | | TEL: (561) 662-8391 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | REVISION: SK-1 4-30-03 | | | | ACTION: DENIED | | | | 1) THE FOUNDATION WORK IS OK TO CONTINUE | | THE PROBLEM IS NOT ENOUGH INFORMATION, | | ON THE PLAN. CAPTAIN MIKE CARCELLO | | THOUGHT A MEETING WITH GEORGE BENAVETAS | | WOULD BE HELPFUL IN DISCUSSING THE | | EXITING ISSUES AT HAND. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | JIM WITMER | | BUILDING PLAN REVIEW | | TEL: (561)659-8096 X 8412 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2003-03-18 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-12 |
Time |
11:33 |
Rev Time |
3.00 |
Received By |
jwitmer |
Date |
2003-03-18 |
Time |
14:05 |
Sent To |
|
|
Notes |
2003-03-18 00:00:00 | | | *** ISSUED PERMIT*** | | -PLAN REVIEW HISTORY- | | | | PERMIT# 02091306 | | ADDRESS: 3600 N AUSTRALIAN AVE | | CONT: HEDRICK BROTHERS | | TELL # (561) 242-4303 | | | | THE ATTACHED COMMENTS ARE PART OF THE | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | BUILDING PLAN REVIEW | | JIM WITMER |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-02-11 |
Time |
10:17 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
2003-02-11 |
Time |
10:17 |
Sent To |
|
|
Notes |
2003-02-11 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 AUSTRALIAN AVENUE | | CONT: HEDRICK BROTHERS | | TEL: (561)659-2383 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | A RESIDENT INSPECTOR TO BE SIGNED | | ON BEFORE PERMIT MAY BE ISSUED. | | | | JIM WITMER | | (561)659-8096 X 8412 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2003-02-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-02-07 |
Time |
12:49 |
Rev Time |
2.25 |
Received By |
jwitmer |
Date |
2003-02-07 |
Time |
12:49 |
Sent To |
|
|
Notes |
2003-02-07 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 N AUSTRALIAN AVE | | CONT: HEDRICK BROTHERS | | TEL: (561)242-4303 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | NOTE: | | | | PLANS ARE TO BE SUBMITTED TO PALM BEACH | | COUNTY FOR IMPACT FEES, ****PLANS ARE TO | | BE STAMPED***** | | | | RESIDENT INSPECTOR TO BE SIGNED ON WITH | | THE CONSTRUCTION SERVICES DEPARTMENT BE- | | FORE PERMIT MAY BE ISSUED. | | | | VOIDED PAGES ARE TO BE RREMOVED FROM | | PLANS & ONE SET OF OLD PLANS TO BE | | SUBMITTED SEPERTAELY WITH PLANS. | | | | DOOR OPENINGS 3/100 AND 4/100 WITH | | SIDELIGHTS AND TRANSOM, MULLION REPORT | | WILL NOT MEET THE PRESSURE REQUIREMENTS! | | OPENING IS SO LARGE THERE IS NO INFORMAT | | ION FOR THIS SIZE OPENING. | | | | JIM WITMER | | BUILDING PLAN REVIEW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2002-12-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-12-19 |
Time |
11:58 |
Rev Time |
3.00 |
Received By |
jwitmer |
Date |
2002-12-19 |
Time |
11:58 |
Sent To |
|
|
Notes |
2002-12-19 00:00:00 | | | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 AUSTRALIAN | | CONT: HEDRICK & BROWN | | TEL: (561)662-8049 GENE GIBSON | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1) COMMENT #1, FROM FIRST REVIEW DEALS | | WITH THE REQUIREMENTS FOR " THRESHOLD | | BUILDINGS", REG SUBMITTED A DEC 18TH, | | IT HAS BEEN DETERMINED BY THE BUILDING | | OFICIAL THAT THIS BUILDING EVEN WITH THE | | REVISION HAS THE CAPACITY TO BE A | | THRESHOLD BUILDING BECAUSE THE FOOT- | | PRINT. ONCE A PERMIT IS ISSUED THE STRUC | | TURE IS UP A REVISION COULD COME IN | | DELETING THE SIDE ENTRY DOORS, THE | | AMOUNT OF SQ FT IN THIS BUILDING AND | | USAGE REQUIRES A "THRESHOLD INSPECTOR" | | AND A STRUCTURAL INSPECTION PLAN. | | FL S. S. 553.71(7) | | 105.13.1 ADMINISTRATIVE CODE | | | | 2) FL BLD CODE 1606.1.5: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORT, SBCCI OR DADE COUNTY | | REPORT ARE ACCEPTED. | | 1606.1.4(1) IN WIND BORNE DEBRIS | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | ASSUMED TO BE OPENINGS UNLESS SUCH | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | WITH AN IMPACT RESISTANT COVERING MEET- | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | LARGE MISSLE TEST. | | MISSING REPORTS: | | A) FIXED & CASEMENT | | B) EXTERIOR DOORS | | C) MULLIONS | | D) ROOFING ASSEMBLIES | | IF NO PRODUCT APPROVALS OR CERTIFI- | | CATE OF COMPLIANCE W/ REFRENCED ENGIN- | | EERING DRAWINGS ARE NOT SUBMITTED WITH | | THE PERMIT APPLICATION , THEN A SEPERATE | | PERMIT WILL BE REQUIRED FOR THE PROTEC- | | TION DEVICE/ ASSEMBLY AND NO CERTIFICATE | | OF OCCUPANCY SHALL BE ISSUED UNTIL | | INSTALLATION OF GLAZING PROTECTION IS | | COMPLETE. FROM CITY IMPLEMENTATION | | STANDARD FOR HURRICANE MISSLE IMPACT | | PROTECTION.(17) | | | | 3)1707.4.5.1 MULLIONS OCCURRING | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | REQUIRED BY AN APPROVED TESTING | | LABORATORY OR BE ENGINEERED. | | | | 4)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | TO THE ROUGH OPENING SUBTRATE. | | | | 5)1503.4.2 OVERFLOW DRAINS SHALL BE | | THE SAME SIZE AS ROOF DRAINS, INSTALLED | | WITH THE INLET FLOW LINE LOCATED 2" | | ABOVE THE LOWEST POINT OF THE ROOF LINE. | | OVERFLOW SCUPPERS SHALL BE A MINIMUM OF | | 4"IN HEIGTH AND SHALL BE PLACED IN WALLS | | OR PARARETS WITH THE INLET FLOW LINE | | NOT LESS THAN 2" ABOVE THE ROOF SURFACE. | | SHEET A-3.0/ A-9.0 SECTION 8 | | INDICATE THROUGH THE WALL DRAINS AND | | ROOF SCUPPER, THE PLAN DOES NOT INDICATE | | THE SECONDARYEMERGENCY OVERFLOW, | | WHICH THE BOTTOM OF THE EMERGENCY OVER- | | FLOW IS TO BE A MINIMUM OF 2" ABOVE THE | | ROOF DECK AND NOT OVER 4" ABOVE THE ROOF | | NO EMERGENCY OVERFLOW ILLUSTRATED! | | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | DESCRIPTION OF THE REVISION MADE, IDEN- | | TIFYING THE SHEET OR SPECIFICATION PAGE | | WHERE THE CHANGES CAN BE FOUND, WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | FOR YOUR ANTICIPATED COOPERATION. | | JIM WITMER | | PLAN REVIEW | | TEL: (561)659-8096 EX.8412 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-10-24 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-12-10 |
Time |
10:28 |
Rev Time |
5.00 |
Received By |
jwitmer |
Date |
2002-10-24 |
Time |
08:28 |
Sent To |
|
|
Notes |
2002-10-24 00:00:00 | | | BUILDING PLAN REVIEW | | PERMIT: 02091306 | | ADD: 3600 AUSTRALIAN AVE | | CONT: HEDRICK BROTHERS | | TEL: (561)242-4303 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1)FL S. S. 553.71(7) " THRESHOLD | | BUILDING" MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT IN | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN | | CY CLASSIFICATION AS DEINED IN THE | | FLORIDA BUILDING CODE WHICH EXCEEDS | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | CONTENT OF GREATER THAN 500 PERSONS. | | 105.13.1 THE ENFORCING AGENCY SHALL | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | BUILDING PURSUANT TO A STRUCTURAL INSPEC | | TION PLAN PREPARED BY THE ENGINEER OF | | RECORD. THE STRUCTURAL INSPECTION PLAN | | MUST BE SUBMITTED TO THE ENFORCING AGEN- | | CY PRIOR TO THE ISSUANCE OF A BUILDING | | PERMIT FOR THE CONSTRUCTION OF A THRESH- | | OLD BUILDING. THE PURPOSE OF THE SRUCTUR | | AL INSPECTION PLAN IS TO PROVIDE SPECIF- | | IC INSPECTION PROCEDURES AND SCHEDULES | | SO THAT THE BUILDING CAN BE ADEQUATELY | | INSPECTED FOR COMPLIANCE WITH THE | | PERMITTED DOCUMENTS. | | | | 2) FL BLD CODE 1804.2.2 QUESTIONABLE | | SOILS, WHERE THE BEARING CAPACITY IS | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | SUBMIT SOILS REPORT WITH THE MINIMUM | | SAFE BEARING CAPACITY. | | | | 3) THE PLANS DO NOT INDICATE THE USE OF | | FIRE SPRINKLERS, FBC 903.7.2.4 REQUIRES | | ASSEMBLY OCC WITH AN OCCUPANCY LOAD | | GREATER THAN 300 PERSONS TO HAVE FIRE | | SPRINKLER PROTECTION. SEE EXCEPTIONS! | | | | 4) FBC 10.19.10.1.4. ASSEMBLY OCCUPANCY | | > 200 PERSONS REQUIRE SEATS TO BE FAST- | | ENED TO THE FLOOR. | | | | 5) 1019.7.2. FBC ASSEMBLY OCCUPANCY,EACH | | DOOR IN A MEANS OF EGRESS FROM AN AREA | | OF GROUP A OCC. REQUIRES PANIC HARDWARE | | OR FIRE EXIT HARDWARE. | | | | 6) TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY | | | | 7)FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | WILL THE BLDG BE USED FOR ANYTHING OTHER | | THAN RELIGIOUS SERVICES? THIS MAY ENACT | | OTHER CODE SECTIONS? FL ACCESSIBILITY | | | | 8)PROVIDE ENERGY CALCULATIONS AND | | EQUIPMENT SIZING CALCULATIONS (MANUAL J) | | AS REQUIRED BY THE 2001 FLORIDA ENERGY | | EFFICIENTCY CODE FOR BUILDING CONSTRUC- | | TION. | | | | 9)1606.1.4(1) IN WIND BORNE DEBRIS | | REGIONS, EXTERIOR GLAZING THAT RECEIVES | | POSITIVE PRESSURE IN BUILDINGS SHALL BE | | ASSUMED TO BE OPENINGS UNLESS SUCH | | GLAZING IS IMPACT RESISTANT OR PROTECTED | | WITH AN IMPACT RESISTANT COVERING MEET- | | ING THE REQUIREMENTS OF SSTD 12, ASTM | | E 1886 AND ASTM E 1996 OR MIAMI-DADE. | | | | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT | | OF GRADE SHALL MEET THE REQUIREMENTS OF | | LARGE MISSLE TEST. | | | | 10)FL BLD CODE 1606.1.5: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORT, SBCCI OR DADE COUNTY | | REPORT ARE ACCEPTED. MISSING REPORTS: | | A) WINDOWS, FIXED OR CASEMENT | | B) EXTERIOR DOORS | | C) MULLIONS | | D) ROOF ASSEMBLIES | | | | 11) 1606.4.4 ANCHOR METHODS. PROVIDE | | INFORMATION FOR INSTALLATION OF DOOR | | AND WINDOW BUCKS. | | | | 12) 1707.4.4.1 ANCHOR REQUIREMENTS: | | WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR | | ED IN ACCORDANCE WITH THE PUBLISHED | | MANUFACTURER'S RECOMMENDATIONS TO | | ACHIEVE THEDESIGN PRESSURE SPECIFIED. | | SUBSTITUTE ANCHORING SYSTEM USED FOR | | THE SUBSTRATE NOT SPECIFIED BY THE | | FENESTRATION MANUFACTURER SHALL PROVIDE | | EQUAL OR GREATER ANCHORING AS DEMONSTRA- | | TED BY ACCEPTED ENGINEERING PRACTICES. | | | | 1707.4.4.2 WINDOW BUCKS TO BE A MINIMUM | | 1 1/2" OR WINDOWS SHALL BE FASTENED TO | | THE STRUCTURAL SUBSTRATE. | | | | 13) 1707.4.5.1 MULLIONS OCCURRING | | BETWEEN INDIVIDUAL WINDOW AND GLASS | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | REQUIRED BY AN APPROVED TESTING | | LABORATORY OR BE ENGINEERED. | | | | 14) 1707.4.5.2 MULLIONS SHALL BE DESIGN- | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | TO THE ROUGH OPENING SUBTRATE. | | | | 15) STRUCTURAL PAGES INDICATE FOR ROOF | | SHEATHING SEE NOTES ON S-9. NOTE WOOD | | 6-E INDICATES TO COMPLY WITH 2322.2 | | WHICH IS FOR HIGH WIND REGIONS, DADE & | | BROWARD COUNTIES. | | SEE PALM BEACH COUNTY AMENDMENTS | | TABLE 2306.1 FOR FASTENING SCHEDULE. | | SEE "LOCAL CONDITIONS"AND FISCAL IMPACT | | FOLLOWING TABLE 2309.3A. | | THE NAILING SCHEDULE IS GOOD FOR | | HEIGHTS TO 35', ABOVE THIS THE ENGINEER | | OF RECORD SHALL INDICATE THE NAILING | | SCHEDULE. THE BEAM OF THE BELL TOWER IS | | AT 37'-8",ROOF SHEATHING ABOVE. | | | | 16)1503.4.2 OVERFLOW DRAINS SHALL BE | | THE SAME SIZE AS ROOF DRAINS, INSTALLED | | WITH THE INLET FLOW LINE LOCATED 2" | | ABOVE THE LOWEST POINT OF THE ROOF LINE. | | OVERFLOW SCUPPERS SHALL BE A MINIMUM OF | | 4"IN HEIGTH AND SHALL BE PLACED IN WALLS | | OR PARARETS WITH THE INLET FLOW LINE | | NOT LESS THAN 2" ABOVE THE ROOF SURFACE. | | | | 17) 1503.4.4 PROTECTION AGAINST DECAY & | | TERMITES. CONDENSATE LINES & ROOF DOWN | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | AWAY FROM THE STRUCTURE SIDEWALL, | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | TENSIONS, OR SPLASH BLOCKS. | | | | 18)1511.7 ROOF MOUNTED MECHANICAL UNIT | | S SHALL BE MOUNTED ON CURBS RAISED A | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | HEIGTH IN ACCORDANCE WITH TABLE 1511.7. | | | | 19) FL BLD CODE 104.2.1.2 | | ADDITIONAL INFORMATION REQUIRED, | | SHEET A-6.4 VS S-2, BELL TOWER, | | SHEET S-2 BELL TOWER DETAIL INDICATES A | | BEAM TB-7 @ ELEVATION +20'-0". THE A-6.4 | | INDICATES A BEAM @ 29"-0" NOT MENTIONED | | IN STRUCTURAL BEAM SCHEDULE. THIS SEC- | | TION IS NOT CLEAR 10/S-5, IS THIS INDICA | | TING RB-12 AND TRUSSES, IS SECTION SHOW- | | ING TRUSSES CANTILEVERED OVER A BEAM @ | | ELE. 129'? | | STRUCTURAL DETAIL, A CUT SECTION LABEL- | | ING ALL BEAMS & COL. WITH ELE. WOULD BE | | HELPFUL. | | | | THE STRUCTURAL DETAIL AND ARCHITECTURAL | | DETAILS DO NOT MATCH, A-6.4 INDICATES | | CONCRETE BEAM BELL TOWER SUPPORTED BY | | 4X8 WOOD BEAM??????????? | | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | DESCRIPTION OF THE REVISION MADE, IDEN- | | TIFYING THE SHEET OR SPECIFICATION PAGE | | WHERE THE CHANGES CAN BE FOUND, WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | FOR YOUR ANTICIPATED COOPERATION. | | JIM WITMER | | PLAN REVIEW | | TEL: (561)659-8096 EX.8412 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-22 |
Time |
14:51 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-10-22 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-02-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-11 |
Time |
06:00 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-02-11 |
Time |
06:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-12-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-06 |
Time |
07:03 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2002-12-06 |
Time |
07:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-10-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-10-07 |
Time |
16:44 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2002-10-07 |
Time |
16:44 |
Sent To |
|
|
Notes |
2002-10-07 00:00:00 | **************** UNSAT ************ | | | | 1)NOTE: PLEASE NOTE TITLE BLOCK MUST | | CONTAIN LICENSE # FOR ENGINEER OF | | RECORD. PER FAC. 61G15-23.002 | | | | 2)NOTE: PLEASE CLARIFY LOCATION OF REQ`D | | GFI FOR A/C UNIT OUTSIDE PER 210-63 | | | | 3)NOTE: PLEASE NOTE CLEARENCE PER 110-26 | | FOR PANEL "B". SHOWN W/ COUNTERTOP | | INFRONT OF PANEL. | | | | 4)NOTE: PLEASE NOTE IF THERE ARE GOING | | TO BE ANY LOW VOLTAGE/ SOUND SYSTEM | | INSTALLED. PLANS WILL BE REQ`D NOW OR | | SUBMITTED AT TIME OF APPLICATION FOR | | PERMIT. | | | | 5)NOTE: PLEASE NOTE RISER DIAGRAM SHOWS | | AN EQUIPMENT GROUNDING CONDUCTOR BETWEEN | | GUTTER AND MAIN DISC`S. PLEASE NOTE, | | NO EQUIPMENT GRND IS INSTALLED DUE TO | | PARALELLING THE NEUTRAL. PER 250-24 | | | | 6)NOTE: PLEASE SUBMIT THE AIC RATING FOR | | MAIN DISC`S. MAINS/PANELS/BRKRS/ ALL | | MUST BE RATED FOR THE AVAILABLE FAULT | | CURRENT. PER 110-9. | | | | 7)NOTE: PLEASE SHOW LOCATION OF SERVICE | | ON BLDG. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2003-11-10 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-11-10 |
Time |
13:40 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2003-11-10 |
Time |
13:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2003-01-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-10 |
Time |
11:13 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2003-01-28 |
Time |
08:04 |
Sent To |
|
|
Notes |
2003-01-28 00:00:00 | 1. PLEASE SEE PERMIT # 03011996 FOR | | CIVIL AND SITE WORKS PERMITTING. | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2002-09-30 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2002-09-30 |
Time |
09:23 |
Rev Time |
4.00 |
Received By |
mamini |
Date |
2002-09-30 |
Time |
09:22 |
Sent To |
|
|
Notes |
2002-09-30 00:00:00 | FAILED: | | 1. A SEPARATE PERMIT APPLICATION AND | | FEES FOR CIVIL SITE AND UNDERGROUND | | UTILITIES WILL BE REQUIRED. | | 2. PLEASE NOTE THAT ALL DRIVEWAY | | APPROACHES MUST BE CONSTRUCTED PER CITY | | OF WEST PALM BEACH STANDARD AND REQUIRE- | | MENTS. | | 3. PLEASE SHOW WATER AND SEWER | | CONNECTIONS FOR THE PROPOSED BUILDING, | | A BACKFLOW PREVENTER ANDCLEAN OUTS ON | | SEWER LATERAL WILL BE REQUIRED. | | 4. ALL PARKING STALLS MUST BE STRIPED, | | USING DOUBLE 4", PER CITY OF WEST PALM | | BEACH REQUIREMENTS. | | 5. PLEASE VERIFY THE STORM WATER CALC. | | AND THE ELEVATIONS AS SHOWN ON SHEET 1 | | OF 2 AND COMPARE WITH DETAILS ON SHEET | | 2 OF 2.ALSO VERIFY THE CONTROL ELEV. | | AND INVERTS ON ENTIRE PREFORATED PIPE. | | 6. A GARBAGE ENCLOSURE THAT COMPLIES | | WITH CITY REQUIREMENT SHOULD BE PROVIDED | | IF CITY PICK-UP. | | 7. CITY OF WPB' STANDARDS AND DETAILS | | MAY BE OBTAINED FROM PUBLIC UTILITIES | | 659-8040 EXT. 2306, MANNY GONZALEZ. | | 8. SEVICE AVAILABILITIES AND LOCATIONS | | FOR BACKFLOW PREVENTERS,METERS SHOULD BE | | COORDINATED WITH PUBLIC UTILITIES, | | 659-8040 EXT. 2306 MANNY GONZALEZ. | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-10-28 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-10-28 |
Time |
14:52 |
Sent To |
|
|
Notes |
2003-10-28 00:00:00 | REVISION DATED 10-21-03 OK |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2003-10-03 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-10-03 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-10-03 |
Time |
14:49 |
Sent To |
|
|
Notes |
2003-10-03 00:00:00 | 1) BUILDING ADDRESS NOTED ON PAGE A-5.0. | | NUMERALS SHALL BE AT LEAST 6" HIGH. | | | | 2) NO LOCKS ARE ALLOWED ON DOORS | | EQUIPPED WITH PANIC HARDWARE. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2003-02-13 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-02-13 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-02-12 |
Time |
09:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-12-12 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-12-12 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-12-12 |
Time |
11:46 |
Sent To |
|
|
Notes |
2002-12-12 00:00:00 | 1) NO OTHER LOCKING DEVICES ALLOWED | | ON EXIT DOORS EXCEPT PANIC HARDWARE. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-10-03 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-10-03 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-10-03 |
Time |
10:24 |
Sent To |
|
|
Notes |
2002-10-03 00:00:00 | 1) | | 1) BUILDING ADDRESS REQUIRED. MINIMUM 6" | | NUMERALS REQUIRED. | | | | 2) THE CHURCH OCCUPANT LOAD EXCEEDS 300 | | PERSONS AND REQUIRES FIRE SPRINKLER | | PROTECTION UNLESS YOU MEET ONE OF | | THE EXCEPTIONS. PLEASE VALIDATE WHAT | | EXCEPTIONS YOU MEET TO EXCLUDE FIRE | | SPRINKLER PROTECTION. | | | | 3) PANIC HARDWARE REQUIRED ON ALL | | EXIT DOORS SUBJECT TO AN OCCUPANCY | | OF 100 OR MORE PERSONS. | | | | 4) PLEASE INDICATE ON PLANS THAT THE | | PEWS SHOWN ON THE DRAWINGS WILL BE | | FIXED TO THE FLOOR. | | | | 5) PLEASE INDICATE INTERIOR FINISH | | CLASSIFICATION INFORMATION FOR THE | | WALLS AND CEILINGS OF THE BUILDING. | | | | 6) PLEASE INDICATE HANDICAPPED SEATING. | | | | 7) ALL STAIRS AND AND RAMPS ARE REQUIRED | | TO HAVE HANDRAILS ON BOTH SIDES. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2003-12-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-10 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-10 |
Time |
11:54 |
Sent To |
|
|
Notes |
2003-12-10 00:00:00 | TO COMM BD#15 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2003-11-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-26 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-26 |
Time |
11:03 |
Sent To |
P |
|
Notes |
2003-11-26 00:00:00 | TO KS BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2003-11-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-17 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-17 |
Time |
08:16 |
Sent To |
|
|
Notes |
2003-11-17 00:00:00 | TO COMM BD#30 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-10 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-10 |
Time |
11:13 |
Sent To |
ENG |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-22 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-22 |
Time |
10:14 |
Sent To |
|
|
Notes |
2003-10-22 00:00:00 | TO COMM BD#21 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-06 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-06 |
Time |
14:05 |
Sent To |
B |
|
Notes |
2003-10-06 00:00:00 | TO JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2003-09-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-22 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-22 |
Time |
14:23 |
Sent To |
B |
|
Notes |
2003-09-22 00:00:00 | TO JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2003-09-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-16 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-16 |
Time |
14:20 |
Sent To |
|
|
Notes |
2003-09-16 00:00:00 | ON COMM BD#62 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-31 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-31 |
Time |
11:33 |
Sent To |
B |
|
Notes |
2003-07-31 00:00:00 | TO JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-07 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-07 |
Time |
15:48 |
Sent To |
B |
|
Notes |
2003-07-07 00:00:00 | JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-06-06 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-06 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-06 |
Time |
08:18 |
Sent To |
B |
|
Notes |
2003-06-06 00:00:00 | JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-05-12 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-12 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-12 |
Time |
11:33 |
Sent To |
B |
|
Notes |
2003-05-12 00:00:00 | JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-05-08 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-08 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-08 |
Time |
13:58 |
Sent To |
|
|
Notes |
2003-05-08 00:00:00 | COMM BOARD #16 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-02-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-04 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-04 |
Time |
12:30 |
Sent To |
|
|
Notes |
2003-02-04 00:00:00 | TO COMM BOARD #37 NEW SHEETS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-11-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-15 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-11-15 |
Time |
16:27 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2003-12-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-12-10 |
Time |
15:22 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2003-12-10 |
Time |
15:22 |
Sent To |
P |
|
Notes |
2003-12-10 00:00:00 | FAXED COPY OF ENG LTR TO CLARIFY SYSTEM | | 1 HAS THE SAME SPECIFICATIONS AS SYSTEM | | 2 AND 3.HARD COPY TO FOLLOW BY FED-EX | | TO THE ARCHITECT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-11-24 |
Time |
08:14 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2003-11-24 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2003-10-17 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-17 |
Time |
06:51 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-10-17 |
Time |
06:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-02-12 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-02-12 |
Time |
10:32 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-02-12 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-12-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-12-05 |
Time |
12:35 |
Rev Time |
1.30 |
Received By |
pkrauss |
Date |
2002-12-05 |
Time |
11:03 |
Sent To |
|
|
Notes |
2002-12-05 00:00:00 | PLAN SHEET M-3 ROOF CURB DETAIL, | | "RTU CURB TO WITHSTAND A 110 MPH WIND | | AS PER SFBC".SPOKE WITH RAJA BUCHANAN, | | P.E. HE WILL FAX A COPY OF A DETAIL WITH | | CORRECT CODE REFERENCE & WIND SPEED | | (FBC & 140 MPH). 3 HARD COPIES TO | | FOLLOW.12-5-02PHK |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-10-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-10-10 |
Time |
15:14 |
Rev Time |
3.00 |
Received By |
pkrauss |
Date |
2002-10-10 |
Time |
10:36 |
Sent To |
|
|
Notes |
2002-10-10 00:00:00 | FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | REQUIRES NOTIFICATION TO ALARM STROBE | | IN NORMALLY OCCUPIED AREAS OR A SUPER- | | VISORY SIGNAL TO BE INDICATED AT A | | CONSTANTLY ATTENDED LOCATION OR CAUSES | | AN ALARM SIGNAL. NFPA 90A 4-4.4.3 & | | 4-4.4.2. | | | | 2001 FBC(M) 306.5, WHERE EQUIPMENT AND | | APPLIANCES REQUIRING ACCESS ARE | | INSTALLED ON ROOFS OR ELEVATED | | STRUCTURES AT A HEIGHT EXCEEDING 16 FT, | | SUCH ACCESS SHALL BE PROVIDED BY A | | PERMANENT APPROVED MEANS OF ACCESS. | | SUCH ACCESS SHALL NOT REQUIRE CLIMBING | | OVER OBSTRUCTIONS GREATER THAN 30 | | INCHES.PLAN SHEET A-3.0 - ROOFPLAN | | KEYNOTES #8 MAINTENANCE ACCESS HATCH, | | NO #8 IDENTIFIED ON PLAN. | | | | CONDENSATE SHALL DISCHARGE A MINIMUM OF | | 12" AWAY FROM THE BUILDING STRUCTURE AS | | PER 2001 FBC 1503.4.4. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2003-12-11 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2003-12-11 |
Time |
08:42 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-12-11 00:00:00 | KNEE WALL INSTALLED IN RM # 104 FAMILY | | RM TO COMPLY WITH W/C 18" OFF WALL.PES |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-12-09 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-12-10 |
Time |
15:22 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-12-09 |
Time |
09:01 |
Sent To |
|
|
Notes |
2003-12-09 00:00:00 | SUBMITTAL OK - WATER TEST RESULTS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2003-10-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-26 |
Time |
11:03 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-10-18 |
Time |
13:29 |
Sent To |
|
|
Notes |
2003-10-18 00:00:00 | NO PLUMBING REVISIONS SUBMITTED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-12-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-12-14 |
Time |
15:37 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2002-12-14 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-10-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-10-12 |
Time |
15:34 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2002-10-12 |
Time |
15:34 |
Sent To |
|
|
Notes |
2002-10-12 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FBC-2001 PLUMBING | | | | 1) SHT A-2.1 HANDICAP STALL MEN'S REST | | ROOM, WATER CLOSET CAN NOT INTRUDE INTO | | THE CLEAR FLOOR SPACE FOR HDCP LAV. | | 2) SHT A10.1 DETAIL #2, FLUSH CONTROLS | | TO BE ON CLEAR SIDE OF W/C SEC 11-4.16.5 | | 3) SHT A10.1 DETAIL #4, TOILET ROOM TO | | BE ADAPTABLE. 11-4.1.3(11). PLEASE SHOW | | DETAILS. W/C TO BE 18" OFF WALL, SHOW | | BACKING FOR GRAB BARS, LAV TO BE ABLE TO | | BE SET AT 34" ECT. | | 4) SHT A10.1 DETAIL #3, 1 URNAL TO BE | | HDCP PER 11-4.22.5. SHOW HEIGHT SECTION | | 11-4.18.2, AND CLEAR FLOOR SPACE SECTION | | 11-4.18.3. | | 5) SHT P.1 SINK IN SACRISTY SHALL DRAIN | | TO SANITARY. SECTION 301.3 | | 6) SHTS P.2/P.3 RELIEF VALVE DRAIN SHALL | | NOT BE TRAPPED. SECTION 504.7.1 | | 7) SHT P.3 WATER RISER DIAGRAM, WATER | | HEATER SHALL REQUIRE THERMAL EXPANSION | | CONTROL. SECTION 607.3.2 | | SHT P-3 WATER RISER DIAGRAM, WATER HAMM- | | ER ARRESTORS REQUIRED BY SECTION 604.9 | | SHALL BE LOCATED NEAR THE FIXTURES IN AN | | "EFFECTIVE RANGE", NOT AT THE TOP OF THE | | DROP IN CEILING AS SHOWN PER PDI-WH 201 | | AND MANUFACTURE INSTALLATION INSTRUCTION | | 8) SEPARATE IRRIGATION PERMIT AND PLANS | | ARE REQUIRED. PLUMBING CONTRACTOR SHALL | | PROVIDE A VALVE AND ADAPTOR FOR IRRG. | | CONTRACTOR. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2002-12-10 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-12-10 |
Time |
10:28 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2002-09-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-15 |
Time |
16:27 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-09-26 00:00:00 | DENIED, NEED LEVEL I SITE PLAN REVIEW | | SENT TO BLDG 9-26-02 |
|
|