Plan Review Details - Permit 02090645
Plan Review Stops For Permit 02090645
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-05 Cont ID  
Sent By rbrown Date 2003-02-05 Time 14:50 Rev Time 0.00
Received By rbrown Date 2003-02-05 Time 14:50 Sent To  
Notes
2003-02-05 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 --PROVISO--
 NO ELEVATIONS SUBMITTED.THE LENGTH OF
 THE REPLACEMENT WINDOWS SHALL BE WITHIN
 THE SCOPE OF THE SUBMITTED SINGLE HUNG
 WINDOW PRODUCT APPROVAL NOA# 01-0226.04

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-01-30 Cont ID  
Sent By rbrown Date 2003-01-30 Time 15:09 Rev Time 0.00
Received By rbrown Date 2003-01-30 Time 15:09 Sent To  
Notes
2003-01-30 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 11/12/02:
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 5) --PROVISO--
 THE LENGTH OF THE REPLACEMENT WINDOWS
 SHALL BE WITHIN THE SCOPE OF THE
 SUBMITTED SINGLE HUNG WINDOW PRODUCT
 APPROVAL NOA# 01-0226.04
  
 6) FBC 13-103.0ENERGY CODE COMPLIANCE
 FORMS.THIS COMMENT HAS NOT BEEN
 ADDRESSED.THE SUBMITTED FORMS STILL
 REFER TO UNIT 3, WHICH DOES NOT EXIST.
 THEREFOR, THE INPUT DATA FOR UNIT 1 & 2
 DOES NOT REPRESENT THE ACTUAL FLOOR,
 WINDOW, WALL AREA ETC FOR THOSE UNITS.
 SEE NOTE BELOW.
  
 NOTE:
 CHAPTER 553.80(2)(B) FLORIDA STATUTES
 STATES THAT A LOCAL GOVERNMENT SHALL
 IMPOSE A FEE OF FOUR TIMES THE FEE FOR
 PLAN REVIEW, IF PLANS ARE REJECTED THREE
 OR MORE TIMES FOR REPEATED FAILURE TO
 CORRECT A CODE VIOLATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-12 Cont ID  
Sent By btrobaug Date 2003-01-29 Time 14:24 Rev Time 0.00
Received By rbrown Date 2002-11-12 Time 15:23 Sent To  
Notes
2002-11-12 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE PROJECT DESCRIPTION ON THE PERMIT
 APPLICATION FORM MAKES REFERENCE TO AN
 ADDITION.AS THERE IS NO CORRESPONDING
 REFERENCE TO AN ADDITION ON THE PLANS,
 SHOULD THE PROPOSAL INCLUDE ADDITIONAL
 FLOOR AREA, THEN AMENDED PLANS SHALL BE
 SUBMITTED TO CLARIFY THE DIFFERENCE
 BETWEEN EXISTING AND PROPOSED LAYOUT.
  
 3) IF ADDITIONAL FLOOR AREA IS PROPOSED
 (SEE COMMENT #2, ABOVE), THEN IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY,
 THE PLANS STAMPED BY THEM AND A COPY OF
 THE RECEIPT SUBMITTED TO CITY OF WEST
 PALM BEACH CONSTRUCTION SERVICES DEPT
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 4) FBC 1005.4EGRESS WINDOWS.THE
 REPLACEMENT WINDOWS FOR BEDROOM 2 OF
 UNIT 1 AND BEDROOM 2 OF UNIT 2 SHALL BE
 EGRESS WINDOWS WITH A MAXIMUM SILL
 HEIGHT OF 44", MINIMUM CLEAR OPENING
 WIDTH OF 20", MINIMUM CLEAR OPENING
 HEIGHT OF 24" AND A MINIMUM NET CLEAR
 OPENING OF 5.7 SQ FT (5.0 SQ FT FOR
 GROUND FLOOR OPENINGS).
  
 5) SUBMIT A WINDOW SCHEDULE OR
 ELEVATIONS SHOWING WINDOW HEIGHTS AND
 WINDOW PRESSURES TO VERIFY THAT THESE
 ARE WITHIN THE SCOPE OF THE SUBMITTED
 PRODUCT APPROVAL NOA# 01-0226.04
  
 6) FBC 13-103.0THE SUBMITTED ENERGY
 CODE COMPLIANCE FORMS REFER TO UNITS 1,
 2 AND 3.SUBMIT FORMS WHICH CORRELATE
 WITH THE SIZE AND NUMBER OF UNITS
 PROPOSED.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-01-29 Cont ID  
Sent By btrobaug Date 2003-01-23 Time 15:42 Rev Time 0.50
Received By btrobaug Date 2003-01-29 Time 13:43 Sent To B
Notes
2003-01-29 00:00:00TO ROBERT BROWN./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-10-09 Cont ID  
Sent By pkrauss Date 2003-01-23 Time 08:57 Rev Time 1.00
Received By btrobaug Date 2002-10-09 Time 07:12 Sent To P
Notes
2002-10-09 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THAT AN ELECTRICAL PERMIT
 IS REQUIRED FOR THIS PROJECT.AT THE
 TIME OF APPLICATION IT WILL BE
 NECESSARY FOR THE ELECTRICAL CONTRACTOR
 TO SUPPLY AIC RATINGS PER 110-9 & 10.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-23 Cont ID  
Sent By btrobaug Date 2003-01-23 Time 15:42 Rev Time 0.00
Received By btrobaug Date 2003-01-17 Time 15:41 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-01-23 Cont ID  
Sent By pkrauss Date 2003-01-23 Time 08:56 Rev Time 0.25
Received By pkrauss Date 2003-01-23 Time 08:51 Sent To E
Notes
2003-01-23 00:00:00NO MECHANICAL PLANS SUBMITTED - ENERGY
 & MANUAL J CALCS INDICATE UNDUCTED PTAC
 UNITS TO BE INSTALLED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-10-19 Cont ID  
Sent By kstevens Date 2003-01-18 Time 12:16 Rev Time 0.50
Received By hmoser Date 2002-10-19 Time 11:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-18 Cont ID  
Sent By kstevens Date 2003-01-18 Time 10:34 Rev Time 0.50
Received By kstevens Date 2003-01-18 Time 10:34 Sent To M
Notes
2003-01-18 00:00:00NO RISER SUBMITTED - BACKFLOW OR METERS

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-10-18 Cont ID  
Sent By btrobaug Date 2002-10-09 Time 12:52 Rev Time 0.33
Received By kstevens Date 2002-10-18 Time 18:17 Sent To M
Notes
2002-10-18 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 NEC-99
  
 1) EACH ELECTRICALLY HEATED APPLIANCE
 THAT IS INTENDED BY SIZE, WEIGHT, AND
 SERVICE TO BE LOCATED IN A FIXED POSIT-
 IONSHALL BE PLACED SO AS TO PROVIDE
 AMPLE PROTECTION BETWEEN THE APPLIANCE
 AND ADJACENT COMBUSTIBLE MATERIAL.
 NEC 422-17. - HEATER SHALL HAVE A WALL
 BETWEEN IT AND COMBUSTABLES IN CLOSED OR
 BE IN SEPARATE CLOSET.
 2) BACKFLOW IS REQUIRED FOR 2 OR MORE
 INDIVIDUAL UNITS, OR INDIVIDUAL WATER
 METERS.
 3) ALL PLUMBING IN OPEN WALLS OR OPEN
 FLOORS SHALL BE INSPECTED PRIOR TO
 COVERING.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2002-11-06 Cont ID  
Sent By sgraham Date 2002-11-06 Time 11:00 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-09-19 Cont ID  
Sent By sgraham Date 2002-09-19 Time 08:56 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-09-19 00:00:00DENIED, BLDG RECORDS SHOW BLDG WAS BUILT
 AS A DUPLEX, BLDG MUST BE CONVERTED BACK
 TO DUPLEX