Plan Review Stops For Permit 02090419 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
23 |
Status |
P |
Date |
2005-06-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-11 |
Time |
18:59 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-06-11 |
Time |
18:59 |
Sent To |
PC |
|
Notes |
2005-06-11 00:00:00 | RAILING SHOPS PREPARED BY STEPHAN YECKES | | PROVISO - TO COMPLY WITH FBC11 FIG 19 | | EXTENSION AT BOTTOM OF RUN |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
22 |
Status |
F |
Date |
2005-06-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-06-01 |
Time |
10:11 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2005-06-01 |
Time |
10:11 |
Sent To |
PC |
|
Notes |
2005-06-01 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)IT IS NOT CLEAR WHAT DESIGN | | PROFESSIONAL IS CERTIFYING THE STRENGTH | | OF THE DESIGN.NO TITLE BLOCK, | | ENGINEERED CALCULATIONS, DESIGN CRITERIA | | PER FBC (FBC1608.2.1(1-3), | | FBC1608.2.2(1-4))OR SEAL WAS PROVIDED. | | | | 2.) THE RAILING SHOPS DO NOT HAVE THE | | JOB NAME ON THEM.WHERE WILL THIS BE | | INSTALLED? | | | | 3.) PAGE 1, PROVIDE HANDRAIL HEIGHT | | FBC1007.5.HANDRAILS REQUIRED BOTH | | SIDES. | | | | 4.)FBC1007.5.5, HANDRAIL SHALL | | CONTINUE TO SLOPE FOR A DISTANCE OF | | DEPTH OF ONE RISER AT THE BOTTOM. | | | | 5.)PAGE 2, DIMENSIONS REQUIRED BY | | FBC1015 ARE NOT ON THE PLAN.WHAT IS | | THE LOCATION FOR THE HANDRAIL SHOWN AT | | THE BOTTOM OF PAGE 2? | | | | 6.)PAGE 3 GUARDRAIL APPEARS TO BE | | DESIGNED WITHOUT THE REQUIREMENT (REJECT | | A 4" OBJECT BETWEEN PICKETS) FBC1015.3. | | PLEASE GIVE LOCATIONS FOR THE | | RAILINGS/GUARDRAILS SUBMITTED. | | | | 7.)DESIGN CRITERIA ON COVER SHEET IS | | NOT COMPLIANT FOR EITHER HANDRAILS OR | | GUARDRAILS. | | | | 8.)HANDRAILS REQUIRED BOTH SIDES, | | FBC1007.5.2. | | | | 9.)ON THE MULLION NOA, PLEASE INDICATE | | WHICH PRODUCT(S) YOU ARE USING.NOT ALL | | ARE COMPLIANT FOR THE SIZES TO BE | | INSTALLED. | | | | 10.) A REVISION FEE WAS CHARGED FOR THE | | PRODUCT APPROVALS (CHANGE FROM APPROVED | | PLAN/SPEC). | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
21 |
Status |
P |
Date |
2005-05-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-05-09 |
Time |
09:56 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-05-09 |
Time |
09:56 |
Sent To |
PC |
|
Notes |
2005-05-09 00:00:00 | LETTER DATED 5/5/05 REGARDING RIDGE TILE | | STEPHAN YECKES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
20 |
Status |
F |
Date |
2005-04-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-04-28 |
Time |
11:11 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2005-04-28 |
Time |
11:11 |
Sent To |
PC |
|
Notes |
2005-04-28 00:00:00 | ****CORRECTIONS**** | | REVISED C1, C2, A1 | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)THE STAIR HANDRAIL IS TO BE IN | | COMPLIANCE WITH FBC1007.5.5, SHALL | | EXTEND 12" BEYOND THE TOP RISER AND THE | | DISTANCE OF ONE TREAD BEYONE THE BOTTOM | | RISER.ALSO SEE FBC CHAPTER 11, FIGURE | | 19. | | | | 2.) SHOW MANEUVERING CLEARANCE FOR THE | | FRONT DOOR, FBC11 FIGURE 25. | | | | 3.) THE HANDRAIL FOR THE RAMP IS TO | | COMPLY WITH FBC1013.7. | | | | 4.)THE RAMP IS TO HAVE HANDRAILS IN | | COMPLIANCE WITH 1013.7 AND EDGE | | PROTECTION 1013.8, 1013.8.2. | | | | 5.)RISERS TO BE A MINIMUM OF 4".A1 | | SHOWS 4" RISERS BUT C1 SHOWS AN | | ELEVATION CHANGE FROM THE LANDING TO THE | | FINISHED FLOOR OF .65', WHICH IS 7.8" | | FOR THE TWO RISERS SHOWN.FBC1007.3. | | | | 6.)SHOW TREAD DEPTH. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
19 |
Status |
P |
Date |
2005-02-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-02-09 |
Time |
16:15 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2005-02-09 |
Time |
16:15 |
Sent To |
|
|
Notes |
2005-02-09 00:00:00 | REVISED SHEETS SP1, A1, A1A, A2, A3, A4, | | A5, A6 DATED 1/25/05 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
18 |
Status |
F |
Date |
2004-11-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-11-19 |
Time |
14:53 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2004-11-19 |
Time |
14:53 |
Sent To |
E |
|
Notes |
2004-11-19 00:00:00 | ****CORRECTIONS**** | | RESTAMP | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SHEETS A1, A5, A6, A7, S2, S3, S4 | | DO NOT MATCH THE APPROVED PLAN. | | | | 2.)SEE PREVIOUS BUILDING REVIEWS #5 | | AND #12.DENIED REVISED SHEETS WERE NOT | | RESUBMITTED; CHANGES APPROVED ON SOME | | SHEETS AFFECTED OTHER SHEETS AND THOSE | | REQUESTED SHEETS WERE NOT BROUGHT IN AS | | REVISIONS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
17 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-07-28 |
Time |
10:01 |
Rev Time |
0.25 |
Received By |
alange |
Date |
2004-07-28 |
Time |
10:01 |
Sent To |
|
|
Notes |
2004-07-28 00:00:00 | RECEIVED LETTER FOR BEAM REPAIR | | OK PER SH |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
16 |
Status |
P |
Date |
2004-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-26 |
Time |
16:29 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-07-26 |
Time |
16:29 |
Sent To |
|
|
Notes |
2004-07-26 00:00:00 | REVISED SHEETS A2 AND A3 DATED 7/16/4 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
15 |
Status |
P |
Date |
2004-07-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-26 |
Time |
15:03 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-07-19 |
Time |
15:09 |
Sent To |
|
|
Notes |
2004-07-19 00:00:00 | LETTER/DETAIL, 1 HR WALL DATED 6/21/04 | | STEPHAN YECKES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
14 |
Status |
F |
Date |
2004-07-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-19 |
Time |
14:34 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-07-19 |
Time |
14:29 |
Sent To |
|
|
Notes |
2004-07-19 00:00:00 | ****CORRECTIONS**** | | ENGINEER'S LETTER (BEAM) | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)PLEASE SPECIFY THE WELD. | | | | 2.)PROVIDE CALCS FOR THE CUT | | REINFORCEMENT TO SHOW THAT NO ADDITIONAL | | STRENGTHENING IS REQUIRED (ITEM 1). | | | | 3.)BOLTS ARE THROUGH BLOCK RATHER | | THAN CONCRETE; PLEASE ADDRESS. | | | | 4.)NOTE THAT GINSBURG ENGINEERIN, LLC | | IS A DIFFERENT ENTITY FROM GINSBURG | | ENGINEERING, INC.A CA NUMBER IS | | REQUIRED FOR GINSBURG ENGINEERING LLC. | | ANY DOCUMENT SIGNED AND SEALED REQUIRES | | THE SAME INFORMATION ON IT AS PLANS DO | | (CA NUMBER FOR GINSBURG ENGINEERING INC) | | | | 5.)A RED TAG HAD BEEN ISSUED REGARDING | | THE CRACKS IN THE PRECAST FOR THE STAIR | | SUPPORT.PLEASE ADDRESS AT THIS TIME. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
13 |
Status |
F |
Date |
2004-07-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-15 |
Time |
16:03 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-07-13 |
Time |
15:59 |
Sent To |
|
|
Notes |
2004-07-13 00:00:00 | ****CORRECTIONS**** | | REVISION - P2,P3,P4,P5,E6 DATED 7/6/04 | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)THE CHANGES APPEAR TO BE | | STRUCTURALLY CODE COMPLIANT.SUBMIT | | REVISED ARCHITECTURAL SHEETS TO SHOW | | THE STRUCTURAL CHANGES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
F |
Date |
2004-07-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-06-30 |
Time |
10:10 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2004-06-30 |
Time |
10:10 |
Sent To |
FIRE |
|
Notes |
2004-06-30 00:00:00 | ****CORRECTIONS**** | | REVISION DATED 6/22/04, SHEETS A1, A2, | | A3, A5, A6, A7 | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)NO CHANGES HAVE BEEN INDICATED ON | | THE REVISED SHEETS.ALSO, THERE IS | | A REVISION DATE OF 2-5-03 WHICH IS NOT | | INCLUDED.ALL CHANGES ARE TO BE | | CLEARLY INDICATED WITH CLOUDS AND/OR | | TRIANGLES. | | | | 2.) THIS CHECKLIST INCLUDES SOME OF | | THE CHANGES FROM THE APPROVED SET OF | | PLANS AS A COURTESY BUT IS NOT INTENDED | | TO BE ALL INCLUSIVE.IT IS THE | | ARCHITECT'S RESPONSIBILITY TO INDICATE | | ALL REVISIONS FOR A COMPLETE REVIEW. | | | | 3.)SOME CHANGES APPEAR TO AFFECT OTHER | | SHEETS WHICH HAVE NOT BEEN REVISED (SITE | | PLAN, FIRE SPRINKLER, ELECTRIC, ????). | | ADDRESS. | | | | 4.)DUMPSTER AREA IS NEW.HAVE PRODUCT | | APPROVALS FOR THE LOUVERED DOORS BEEN | | SUBMITTED? IT WAS SHOWN AS A MECHANICAL | | ROOM PREVIOUSLY, WAS MECHANICAL REVISED? | | THE LOUVERED DOOR IS TO COMPLY WITH | | FBC705.1.1.2. | | | | 5.)ACCESSIBILITY DETAILS ARE NOW | | MISSING FROM REVISED SHEETS A2 AND A3. | | THEY MAY BE SUBMITTED AS A SEPARATE | | SHEET. | | | | 6.)SHEET A5, THE IMPACT GLASS ON THE | | FIRST FLOOR HAS BEEN CHANGED TO NON- | | IMPACT WITH SHUTTERS.WHERE WILL THE | | SHUTTERS BE STORED, AND IN WHAT MANNER? | | IF STORED VERTICALLY, PROVIDE A DETAIL | | FOR THE RACK. | | | | 7.)THE WINDOW AND DOOR SCHEDULES | | HAVE CHANGED.SHEET A6 ALSO HAS | | WINDOW AND DOOR CHANGES.ALL CHANGES | | SHOULD BE CLOUDED. | | | | 8.)THE BUILDING FOOTPRINT AND DOOR | | LOCATIONS NO LONGER MATCH THE APPROVED | | SITE PLAN.REVISE SP1 FOR ZONING | | REVIEW.AREA TOTAL FOOTAGE ALSO APPEARS | | TO HAVE CHANGED, PLEASE REVISE. | | | | 9.)CONTACT IMPACT FEES AT 233-5025 | | TO DETERMINE IF AN IMPACT FEE REVIEW | | IS REQUIRED DUE TO THE SMALL INCREASE | | IN SQUARE FOOTAGE. | | | | 10.) DOOR #1 MAY NEED TO COMPLY WITH | | FBC11-4.13.5 (DOOR CLEARANCE, | | ACCESSIBILITY).EITHER THIS DOOR IS | | TO COMPLY WITH THIS CODE SECTION OR | | AN ALTERNATE DOOR WHICH DOES COMPLY | | IS REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
F |
Date |
2004-06-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-06-29 |
Time |
17:21 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-06-29 |
Time |
17:08 |
Sent To |
|
|
Notes |
2004-06-29 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)THE ARCHITECT IS TO CLOUD OR | | OTHERWISE CLEARLY INDICATE ALL CHANGES. | | THIS CHECKLIST INCLUDES SOME OF THE | | CHANGES WHICH I HAVE NOTED BUT IT IS | | NOT INTENDED TO BE ALL INCLUSIVE AND | | IT IS THE ARCHITECT'S RESPONSIBILITY | | TO MAKE NOTE OF ALL CHANGES TO THE | | PLAN. | | | | 2.) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
F |
Date |
2004-06-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-23 |
Time |
15:02 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2004-06-03 |
Time |
07:39 |
Sent To |
|
|
Notes |
2004-06-03 00:00:00 | ****CORRECTIONS**** | | REVISION - TOWER DETAIL FOR EVERNIA | | STATION | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 | | | | 1.)THE HARDIPLANK SIDING IS SHOWN AS | | BEING ATTACHED DIRECTLY TO THE METAL | | FRAMING RATHER THAN OVER PLYWOOD | | SHEATHING.IS THIS CORRECT?IF THIS | | IS CORRECT, PROVIDE INFORMATION TO SHOW | | THAT THE WALLS HAVE MAINTAINED | | STRUCTURAL INTEGRITY. | | | | 2.)PROVIDE A TEST REPORT FOR THE | | HARDIPLANK.CONFIRM INSTALLATION AND | | ATTACHMENT SHOWN ON THE DETAIL WITH | | THE TEST REPORT. | | | | 3.)THE CHANGE FROM STUCCO TO SIDING | | AFFECTS OTHER DETAILS ON THE PLAN. | | SUBMIT REVISED SHEETS SHOWING THE | | CHANGE. | | | | 4.)WINDOW PRODUCT APPROVALS WERE | | ISSUED WITH A PROVISO TO HAVE THE | | ARCHITECT REVISE THE PLAN WHICH HAD | | CHANGES DONE WITH WHITE OUT.PROVIDE | | THIS REVISION AT THIS TIME. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
P |
Date |
2004-05-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-05-19 |
Time |
08:36 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-05-19 |
Time |
08:36 |
Sent To |
|
|
Notes |
2004-05-19 00:00:00 | PROVISO - REVISE SHEETS WITH CHANGED | | WINDOW SIZES (HAD BEEN ALTERED WITH | | WHITE OUT BY CONTRACTOR) | | | | CALLED ARCHITECT, DID NOT RECEIVE A | | CALLBACK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-18 |
Time |
08:30 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-04-19 |
Time |
16:35 |
Sent To |
|
|
Notes |
2004-04-19 00:00:00 | REVISION, FRAMING DETAIL 3/9/4 | | SUBMITTAL, TRUSSES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2004-04-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-16 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2004-04-08 |
Time |
06:49 |
Sent To |
|
|
Notes |
2004-04-08 00:00:00 | THE SCOSTA STEEL ROOF TRUSSES ARE | | REQUIRED TO BE REVIEWED BY THE ENGINEER | | OF RECORD BEFORE SUBMITTING TO THE CITY. | | | | THE ENGINEERING SHOWN AS STANDARD TRUSS | | DETAILS DATED 2/9/04 ISNOT SIGNED AND | | SEALED WITH THE ORIGINAL SIGNATURE AND | | EMBOSSED SEAL. | | | | THE TRUSS ENGINEERING SHEETS SHOW | | BEARING AREAS FOR THE INDIVIDUAL | | TRUSSES TO BE DIFFERENT THAN THOSE | | SHOWN ON THE PLANS IN SECTIONS 1 AND 3, | | SHEET S8. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-06 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-07-01 00:00:00 | REVISIONS S1, 5, 6, AND 8 DATED 6/23/03. | | | | THE GINSBURG ENGINEERING CALCULATIONS | | CITE ACI 318-95 AND 1997 UBC.FURTHER, | | THE CALCULATIONS DO NOT IDENTIFY THE | | PLANS OR PROJECT BEING ANALYZED. | | | | SEE THE 2001 FLORIDA BUILDING CODE AND | | CHAPTER 61G15-30, RESPONSIBILITY RULES | | COMMON TO ALL ENGINEERS, OF THE FLORIDA | | ADMINISTRATIVE CODE. | | | | THE ARCHITECT'S USE OF NUMBERED TRIANGLE | | SYMBOLS FOR BOTH FOOTING TYPE AND | | REVISON NOTES IS A CAUSE FOR CONFUSION, | | PLEASE USE AN ALTERNATE METHOD.FBC | | 104.2. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2003-06-17 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-24 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-06-17 |
Time |
13:01 |
Sent To |
|
|
Notes |
2003-06-17 00:00:00 | SHEET S1 REVISIONS DATED 6/11/03 AND | | "FOOTERS AND AERIAL FACADE EASEMENT | | AGREEMENT" | | | | PLEASE PROVIDE STRUCTURAL CALCULATIONS | | FOR THE PROPOSED CHANGE OF THE | | FOUNDATIONFROM 81"W X 20"D CONTINUOUS | | FOOTING ON 7500 PSF SOIL TO THE 44"W X | | 24"D CONTINUOUS FOOTING FOR AN | | UNDECLARED SOIL BEARING PRESSURE. | | | | PLEASE REVISE THE PAGES AND SECTIONS OF | | THE PLANS THAT WILL BE EFFECTED BY THIS | | CHANGE, SUCH AS, BUT NOT LIMITED TO | | SHEETS S6, S7 & S8. | | | | PLEASE PROVIDE A DETAIL FOR LOCATING | | THE WALL ON THE FOOTING SO AS TO ENSURE | | THE 1.34' EASEMENT AND DEPTH OF TOP OF | | FOOTING AS DESCRIBED IN THE 4/28/03 | | AGREEMENT WITH THE CITY. | | | | PLEASE PROVIDE THE PLANS CALLED FOR IN | | ITEM #2 OF THE AGREEMENT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2003-06-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-12 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-06-11 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-03-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-10 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-03-10 |
Time |
14:00 |
Sent To |
|
|
Notes |
2003-03-11 00:00:00 | OWES IMPACT AND PERMIT FEES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-01-31 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-01-31 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-01-29 |
Time |
15:30 |
Sent To |
|
|
Notes |
2003-01-31 00:00:00 | THERE IS NO HANDICAP PARKING SPACE | | SHOWN IN THE GARAGE AS REQUIRED BY FBC | | 11-4.1.2 (5) | | | | THE AREA OF THE OPENINGS ON THE EAST | | SIDE EXCEEDS THE 10% PERMITTED BY FBC | | TABLE 600 FOR EXTERIOR BEARING WALLS 3' | | - 10'FROM A PROPERTY LINE.THE BOARD | | OF APPEALS VARIANCE WAS FOR | | "PROTECTION" OF THE OPENINGS NOT THE | | AREA.PLEASE REVISE AS NECESSARY. | | | | THE STAIR SHAFT DOORS ARE REQUIRED TO BE | | 1 HR RATED DOORS AS PROVIDED FOR IN | | FBC TABLE 705.1.2. | | | | SHEET A6 CALLS OUT VARIOUS PRECAST STONE | | AND CONCRETE ARCHITECTURAL DETAILS. | | SHOW A SPECIFIC ATTACHMENT DETAIL.SEE | | FBC 104.2. | | | | SHEET S6 REFERENCES THE STANDARD | | BUILDING CODE AND SECTION 1205.2 FOR | | "LOW RISE BUILDINGS"THE STATE OF | | FLORIDA IS UNDER THE 2001 FLORIDA | | BUILDING CODE AND THE STANDARD BUILDING | | CODE LAST HAD STRUCTURAL INFORMATION IN | | CHAPTER 12 IN 1991. | | WHAT IS THIS ARCHITECT USING FOR DESIGN? | | | | THE STRUCTURAL SHEETS CALL OUT 7500 PSF | | SOIL AND 2500 PSF IS DECLARED ON S6 | | UNDER FOUNDATION DESIGN. CLEARLY DEFINE | | THE EXTENT OF THE DIFFERENT BEARING | | VALUES. | | | | SHEETS S3 & S4.DEFINE THE TRANSITION | | OF BEAM TYPES 7 TO 8 AND 8-10-9 AS | | SHOWN ON THE PLANS FOR THE VARYING | | DEPTHS OF 24" 13" AND 29" AND DIFFERENT | | STEEL SIZE.CLARIFY THE DESIGN DEPTH | | OF MARKS 6, 10 AND 14. | | | | HOW WILL THE MINIMUM 3" SPANCRETE | | BEARING BE MAINTAINED ON THE | | LONGITUDINAL INTERIOR BEARING WALL WITH | | BEAMS SHOWN AS 6, 10 AND 14? REFERENCE | | SECTION 2/S8 OF THE PLANS. | | | | DETAIL 6/S9 AND 7/S9.CLARIFY HOW THE | | 2'LONG #4 BAR WILL BE GROUTED INTO THE | | SPANCRETE SLAB JOINT. | | | | SHEET S8.WHAT EXACTLY COMPRISES AN | | "APPLIED WATERPROOFING AGENT" ?SEE | | FBC 2111.1.9 AS AMENDED BY THE CITY. | | | | IS THE ARCHITECT YECKE THE STRUCTURAL | | ENGINEER OF RECORD?WHERE ARE THE | | PREVIOUSLY REQUESTED CALCULATIONS? | | | | THE CALCULATIONS PREPARED BY GINSBURG | | ENGINEERING, LLC INDICATE A HIPPED ROOF | | BUILDING.THE MASONRY INVESTIGATION | | USED ASCE 7-93.(THE FBC INVOKES ASCE | | 7-98) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-10-09 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-10-08 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2002-10-07 |
Time |
15:57 |
Sent To |
|
|
Notes |
2002-10-09 00:00:00 | SHEET A1 AND SEVERAL OTHER PLACES ON THE | | DRAWING CALL OUT DESIGN TO THE 1997 | | STANDARD BUILDING CODE.THE 2001 | | FLORIDA BUILDING CODE IS CURRENTLY IN | | EFFECT.PLEASE REVISE AS NECESSARY TO | | INSURE COMPLIANCE WITH THE CURRENT | | CODES. | | | | DO NOT QUOTE THE CODE, SUCH AS THAT ON | | SHEET A1 "PUBLIC RESTROOM WALLS ARE TO | | BELINED WITH AN NONABSORBANT MATERIAL | | TO A HEIGHT OF 4' AFF AS PER SBC | | 1204.2."THE FORE GOING IS NOT A | | SUBSTITUTE FOR SPECIFIC DESIGN | | INFORMATION.A SPECIFICATION SUCH AS | | THE USE OF TILE IS MORE TO THE POINT. | | PLEASE READ FBC 104.2.1. | | | | SHEET A5, DETAILS #1 & #2, SPECIFY HOW | | THE SUSPENDED CEILING WILL BE ATTACHED | | TOTHE OVERHEAD STRUCTURE. | | | | THIS BUILDING WILL BE LOCATED IN THE | | DESIGNATED FIRE DISTRICT AND IS SUBJECT | | TO THOSE REQUIREMENTS CONTAINED IN THE | | AMENDMENTS TO THE FBC BY THE CITY OF | | WPB.SHEET A6 CALLS OUT THE USE OF | | FOAM BASED EXTERIOR TRIM.FBC F102.2.7 | | ALLOWS ONLY NON-COMBUSTIBLE MATERIALS | | OR FIRE RETARDANT TREATED WOOD.PLEASE | | REVISE AS NECESSARY. | | | | PROVIDE SPECIFIC DESIGN INFORMATION FOR | | THE "PREFAB BALLUSTRADE" CALLED OUT ON | | SEET A6.SEE FBC 1015 AND FBC 1608.2. | | | | SECTION 6/A9 SHOWS A WOOD FRAMED ARCH. | | THE BUILDING IS PROPOSED TO BE OF TYPE | | IV, FS CONSTRUCTION, AND AS SUCH THE | | EXTERIOR WALLS AND ITS COMPONENTS ARE | | REQUIRED TO BE OF NON-COMBUSTIBLE | | CONSTRUCTION.SEE FBC 606. | | | | SHEET A9 CALLS OUT A 110 MPH WINDSPEED | | FOR DESIGN OF THE ROOF TRUSSES.WEST | | PALM BEACH IS IN A 140 MPH ZONE AS | | DEFINED IN THE 2001 FBC. | | | | SHEET S1 CALLS FOR A FINISH FLOOR | | ELEVATION OF 18" ABOVE THE CROWN OF THE | | ROAD.SHOW HOW THIS WILL BE | | COORDINATED WITH THE SURROUNDING | | TOPOGRAPHY.SHOW THE HC ACCESSIBLE | | ENTRANCES, SITE AMENITIES, IE CURBCUTS | | AND OTHER PERTINENT INFORMATION.SEE | | FBC 104.2. | | | | THE FOUNDATION PLAN DOES NOT HAVE | | INFORMATION FOR THE CONSTRUCTION OF THE | | ELEVATOR PIT. | | | | THE TOP OF FOOTING ELEVATIONS IS NOT | | CALLED OUT. | | | | IT APPEARS THAT THE STEM WALL FOOTING | | SHOWN AS [2] WILL EXTEND BEYOND THE | | PROPERTY LINE INTO PUBLIC AND PRIVATE | | PROPERTY.PLEASE REVISE AS NECESSARY. | | | | S1 SHOWS A 6' WIDE CONC WALK IN THE | | GARAGE AND A1 4'.PLEASE CLARIFY | | DESIGN INTENT. | | | | SHEET S2, BEAM SCHEDULE MARK #6, "8 INCH | | X CONT" IS SOMEWHAT VAGUE AS TO WHAT IS | | INTENDED TO BE CONSTRUCTED. | | | | SHEET S2 BEAM SCHEDULE MARK #4. | | "LINTEL" IS DIFFICULT TO CONSTRUE AS | | SPECIFIC STRUCTURAL DESIGN INFORMATION. | | PLEASE CLARIFY DESIGN INTENT. | | | | WHERE DOES BEAM MARK #5 OCCUR ON THE | | STRUCTURAL PLANS WHEN REFERENCED TO | | SHEET A6 WHICH CALLS OUT AN 8X8 LINTEL? | | | | WHAT IS THE LINE SHOWN AS "NO STEP" ON | | SHEET S1 IN THE GARAGE? | | | | SHEET S2,3&4, WHAT IS THE TYPE OF BEAM | | TO BE USEDIN THE STAIR AND ELEVATOR | | SHAFTS? | | | | S-2 BEAM MARK 1, "ARCHED OPENING" | | WHERE ARE THE DIMENSIONS FOR THIS ARCH? | | ARE THERE ANY PERTINENT STEEL PLACEMENT | | DETAILS? | | | | SHEET S3.SHOW A DETAIL FOR TRANSITION | | OF THE BEAM TYPE [7] TO BEAM TYPE [8] | | INCLUDING THE JUNCTURE OF THE FILLED | | CELL.SAME FOR [11] AND [12] ON S4. | | | | STRUCTURAL.AT WHAT HEIGHT DOES THE | | ELEVATOR SHAFT TERMINATE? BEAM | | DEATAILS? ROOF CONSTRUCTION? | | | | SHEET S5. THE WIND INFORMATION DOES NOT | | MAKE SENSE.GCP IS THE PRODUCT OF | | EXTERNAL PRESSURE COEFFICIENT AND GUST | | EFFECT FACTOR NOT THE INTERNAL PRESSURE | | COEFFICIENT. | | | | R3 IS NOT A BUILDING CATEGORY. | | | | THE MEAN ROOF HEIGHT OF THIS BUILDING | | IS NOT <30'.IT IS DECLARED AS 37'-8" | | ON THE SECTION ADJACENT TO THE DESIGN | | INFORMATION AND AN ELEVATOR SHAFT OF | | INDETERMINATE HEIGHT. | | | | | | S5 UNDER THE HEADING "DESIGN | | PARAMETERS" WHAT RELEVANCE DO THESE | | STATEMENTS HAVE TO THE BUILDING ON | | THESE PAGES? | | | | S6 DECLARES 1997 SBC AND 110 MPH, THE | | WRONG EDITIONS OF ACI ARE CITED. 4.04 | | CALLS FOR AND F'M OF 1900 PSI AND 4.08 | | CALLS OUT 1500 PSI. | | | | C/S6 PROVIDE SPECIFIC INFORMATION FOR | | THE TRUSSES AND A BETTER ANCHORING | | SYSTEM THAT "4 X MTL CHANNELS @ 24" OC | | ATTACHED TO SLAN AND TRUSSES" | | | | C/S6 WHAT ARE THE "18 GA MTL STUDS TYP" | | TYPICAL OF?WILL THEY BE FASTENED TO | | THE STRUCTURE? COVERED WITH SHEATHING? | | | | C/S6 "4X4X5/8 ANGLE ANCHOR TO CONC" HOW? | | | | SHEET S7WHERE IS THE STRUCTURAL | | INFORMATION FOR THE POURED CONCRETE | | STAIRS AND LANDINGS.THE NOTE SAYS SEE | | SHOP DRAWINGS FOR ALL STRUCTURAL | | DETAILS.WHERE IS THE DESIGN | | PROFESSIONAL HERE? | | | | S7 HAND RAIL DESIGN IS NOT SHOWN. | | QUOTING AND OBSOLETE CODE SECTION IS | | NOT AN ACCEPTABLE SUBSTITUTE FOR | | SPECIFIC DESIGN INFORMATION. | | | | SECTION 1/S8.THE SMALL TRUSSES AT THE | | 12' HEIGHT.SHOW SOME DESIGN | | INFORMATION.INCLUDE ATTACHMENTS TO | | THE BUILDING.SPECIFY THE SHEATHING, IF | | ANY.SHOW THE ROOF TILE ATTACHMENT. | | "FLASH AS REQUIRED" IS NOT GOOD DESIGN | | INFORMATION. | | | | SECTION 1/S8 AT THE 32'-8" ELEVATION. | | HOW IS THE 22 GA METAL DECKING ATTACHED | | TO THE ROOF TRUSSES?RE: THE STATEMENT | | THAT CONTAINS "NON-COMBUSTIBLE ROOF | | SHEATHING FASTENED TO MEET SCHEDULED | | UPLIFT WIND LOADS" IS NOT THE PREFERRED | | METHOD OF CONVEYING INFORMATION WHEN | | DELEGATING STRUCTURAL DESIGN.SEE FL | | STATUTE CHAPTERS 471 AND 481. | | | | SECTION 4/S9.PROVIDE PRODUCT | | EVALUATION IFORMATION FOR THE 1" | | FIRESTALL ROOF DECKING.HOW ARE THE | | ROOF TILES ATTACHED? | | | | 8/S9."NON BEARING WALL ABOVE SUPPORTED | | BY 10" GATECORE WITH ON SUPPORT WALL | | BELOW"WHAT DOES THAT MEAN AND WHERE IS | | THE DETAIL TAKEN FROM IN THE BUILDING? | | | | CITY AMENDMENTS TO FBC 2111.1.9 REQUIRE | | A 1.5" WATER STOP RECESS FOR EXTERIOR | | WALL MASONRY UNITS.PLEASE REVISE AS | | NECESSARY. | | | | PROVIDE A STATEMENT ON THE PLANS FROM | | THE ARCHITECT THAT HE IS COMPETENT TO | | PROVIDE STRUCTURAL DESIGN FOR THIS | | BUILDING, TOGETHER WITH COMPLETE | | CALCULATIONS DEMONSTRATING COMPLIANCE | | WITH FBC CHAPTER 16. | | | | PROVIDE IN DETAIL, PLANS, SPECIFICATIONS | | AND COMPUTATIONS NECESSARY TO | | DETERMINECOMPLIANCE WITH FBC 104.3.1.1, | | 104.2.1.1,FBC 1606.1.7 | | | | PROVIDE THE SIGNED AND SEALED DESIGN | | INFORMATION FOR THE FIRE SPRINKLER | | SYSTEM. THE HYDRAULIC CALCULATIONS DO | | NOT APPEAR TO INCLUDE THE WATER | | CURTAIN/EXPOSURE ALLOWANCE. | | | | THE PROPERTY SURVEY MUST BE SIGNED, | | SEALED AND DATED. | | | | SOME OF THE METRO-DADE NOA'S ARE EXPIRED | | AND/OR ILLEGIBLE. PLEASE COLLATE AS | | NECESSARY. | | | | SHOW THE FIRE DESIGN NUMBERS FOR THE | | FIRE RATED ASSEMBLIES SUCH AS EXTERIOR | | WALLS, TENANT SEPARATION, SHAFTS, ETC. | | SEE FBC 701.2.1. | | | | PROVIDE DESIGN INFORMATION AND | | CALCULATIONS FOR THE GARAGE EXHAUST | | SYSTEM.SEE FBC 411.4. | | | | SHOW THE OPENING PROTECTIVES FOR THE | | GARAGE DOOR AND THE "AIR EXCHANGE UNIT" | | ON THE SOUTH SIDE. (ALLEY CENTERLINE IS | | 7.5')SEE FBC 705.1.1.2. | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | ISSUED IMPACT FEES MUST BE PAID TO THE | | COUNTY, THE PERMIT PLANS STAMPED BY | | THAT OFFICE, AND A COPY OF THE PAID | | RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. CALL 561-233-5025 FOR MORE | | INFORMATION. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
F |
Date |
2004-11-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-11-23 |
Time |
14:31 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-11-23 |
Time |
14:31 |
Sent To |
|
|
Notes |
2004-11-23 00:00:00 | ****** UNSAT **** | | | | 1)NOTE: PLEASE SEE PLANS DO NOT MATCH W/ | | PLANS WE HAVE ON FILE. | | THESE WOULD BE SUBMITTED AS REVISIONS | | AND THEN REVIEWED FOR CODE COMPLIANCE. | | | | 2)NOTE: PLEASE SEE A RE-STAMP FEE OF $25 | | | | IS OWED. | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-23 |
Time |
08:29 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-07-23 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2004-07-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-08 |
Time |
14:53 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-07-08 |
Time |
14:53 |
Sent To |
|
|
Notes |
2004-07-08 00:00:00 | ************** UNSAT ***************** | | | | 1)NOTE: PLEASE CORRELATE SPECS SHEETS, | | PLANS AND LOAD CALCULATIONS. | | | | SOME ARE SHOWN ON PANEL SCHEDULES ETC | | AS 8.5KW AS SHOWN ON SPEC SHEET. | | SOME ARE SHOWN AS 8KW? | | LOAD CALCULATIONS INDICATE 8KW ALSO? | | | | 2)NOTE: PLEASE SEE SPEC SHEET SUBMITTED | | INDICATES UNITS AS BEING 220V. PLEASE | | SEE THIS IS A 2089 VOLT SERVICE. | | PLEASE SEE SPEC SHEET MENTIONS THAT 208V | | UNITS ARE AVAILABLE. PLEASE VERIFY | | VOLTAGE ON NAMEPLATE ON UNIT. IF UNITS | | ARE RATED FOR 220V AS SHOWN ON SPEC | | SHEETS AND SERVICE IS 208V, UNITS WILL | | HAVE TO BE CHANGED. | | | | PLEASE VEROFY ALL OF THE ABOVE AND | | CORRELATE PLANS ETC. | | | | PLEASE NOTE: AS OF THIS REVIEW, A SIGNED | | SEALED NOTORIZED LETTTER HAS NOT BEEN | | RECEIVED FROM ARCH FOR LEGAL SIGNATURE | | VERIFICATION TO BE PLACED IN SIGNATURE | | FILE. SIGNATURE ON PLANS HAVE NOW | | CHANGED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-23 |
Time |
19:18 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-06-23 |
Time |
19:18 |
Sent To |
|
|
Notes |
2004-06-23 00:00:00 | ************* UNSAT ****************** | | | | 1)NOTE: PLEASE SEE 422.13, MIN OCP FOR | | WATER HEATING UNIT IS TO BE A MIN OF | | 125% OF NAMEPLATE KW. | | PLEASE ADJUST OCP/ AWG. | | SHOWS 30A, #10 | | | | 2)NOTE: PLEASE SEE "INSTA-HOTS" THAT | | WERE WATER HEATERS HAVE NOW BEEN MOVED | | FROM MECH/AREA RMS TO CLOTHES CLOSET. | | THIS IS NOT PERMITTED. | | 422.17 | | | | PLEASE ALSO SEE PLUMB NOTE PERTAINING | | TO ARCH'S LEGAL SIGNATURE. | | PLEASE PROVIDE LETTER AS REQUESTED FOR | | FILE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2004-06-17 |
Time |
09:05 |
Rev Time |
0.45 |
Received By |
jleahy |
Date |
2004-06-17 |
Time |
09:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-03-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-13 |
Time |
07:55 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-03-13 |
Time |
07:54 |
Sent To |
|
|
Notes |
2003-03-13 00:00:00 | ************ PROVISO/ NOTES************* | | | | 1)NOTE: PLEASE CIRCUIT EM/EXT LTS PER | | 700-12E. | | | | PLEASE REVISE AND SUBMIT THE ABOVE | | INFORMATION FOR REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-01-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-29 |
Time |
07:21 |
Rev Time |
2.50 |
Received By |
dpalmer |
Date |
2003-01-29 |
Time |
06:07 |
Sent To |
|
|
Notes |
2003-01-29 00:00:00 | *************** UNSAT **************** | | | | PLEASE SEE THE FOLLOWING NOTES, THERE | | ARE NOTES FROM FIRST TWO REVIEWS THAT | | WERE NOT ADDRESSED. PLEASE SEE THE | | ATTACHED LETTER WITH RESPECT TO DESIGN | | PROFESSIONALS UNDER FS.553-80(2)(B). | | THIS IS THE 3RD TIME THESE PLANS HAVE | | BEEN IN FOR REVIEW. | | | | 1)NOTE: PLEASE SEE PANEL "E", SHOWN AS | | 30 CIRCUIT AND 24 CIRCUIT. PLEASE REVISE | | | | 2)NOTE: IT IS NOTED THAT THERE IS A NOTE | | MENTIONING ALL EM/EX LTS TO BE WIRED ON | | SAME BRANCH CIRCUIT AHEAD OF SWITCHING. | | HOWEVER PLAN CIRCUITING DOES NOT | | CORRELATE WITH THIS NOTE?? | | | | 3)NOTE: PLEASE SUBMIT AND SHOW ALL AIC | | RATINGS FOR ALL NEW EQUIPMENT BEING | | INSTALLED. MAINS, BRKRS, PANELS ARE | | ALL TO BE RATED FOR THE AVAIABLE FAULT | | CURRENT. 110-9 | | | | 4)NOTE; PLEASE SEE SD IN UNIT "B", | | SHOWN IN KITCHEN AND W/IN 3'OF BATHROOM | | DOOR. PLEASE RELOCATE TO A MIN OF 3' | | FROM BATH DOOR AND OUT OF KITCHEN. | | SD MAY BE MOVED JUST INTO LIVING ROOM | | AREA. NFPA-72 8-1.4.1.6 | | | | 5)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | PROTECTED CIRCUITS ON PANEL SCHEDULE | | PER 210-12. IT WAS NOTED ON PLAN BUT | | NEEDS TO BE ON PANEL SCHEDULES. | | | | 6)NOTE: PLEASE ADDRESS COMMENT FOR FHAR | | 24 CFR 100.205. REQ`MENTS ARE TO BE | | NOTED ON PLANS. RECEPT AND SWITCH HEIGHT | | (S) ARE 18 AND 48" WHICH CONFORM, BUT | | THERE ARE OTHER REQ`MENTS. PLEASE NOTE | | ON PLANS FHAR. | | | | 7)NOTE: PLEASE CLARIFY WHERE LOAD | | CALCULATIONS ARE FOR HOUSE PANELS.?? | | 215-5 | | | | 8)NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTOR BETWEEN MAIN DISC | | AND HOUSE PANEL. SIZE PER 250-122 | | | | 9)NOTE: PLEASE SEE PLANS, PANEL SCHEDULE | | -S AND RISER DIAGRMA DO NOT INDICATE | | HOW PANEL "E" IS FED?? PLEASE REVISE. | | NOT SHOWN COMING FROM PANEL HS? | | PLEASE CLARIFY. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. ONCE AGAIN, IF THERE ARE ANY | | QUESTIONS, OR IF A MEETING IS DESIRED | | TO GO OVER COMMENTS, PLEASE CALL. | | | | DEWEY PLAMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-09-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-09-18 |
Time |
06:40 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2002-09-18 |
Time |
06:40 |
Sent To |
|
|
Notes |
2002-09-18 00:00:00 | ******************** UNSAT *********** | | | | 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | THAT MAY HAVE AN AFFECT ON ELECTRICAL | | PLANS. | | | | 2)NOTE: PLEASE NOTE CIRCUITING NEEDS TO | | BE SHOWN FOR ALL BRANCH CIRCUITS ON | | PLANS. | | | | 3)NOTE: PLEASE NOTE EM LTS/EXITS LTS TO | | BE ON SAME AREA BRANCH CIRCUITS. PLEASE | | SEE 700-12 NEC. | | | | 4)NOTE: PLEASE CLARIFY EM LT BEING SHOWN | | TIED INTO TELEPHONE LINE.? (SECOND FLOOR | | | | 5)NOTE: PLEASE PROVIDE ROOM DESIGNATIONS | | ON PLANS. | | | | 6)NOTE: PLEASE CLARIFY/LABEL PANEL SHOWN | | ON E-2 LAUNDRY AREA? | | | | 7)NOTE: IT WAS NOTED THAT A 3/4" CONDUIT | | STUB UP FOR TELE. PLEASE NOTE AND NOTE | | ON PLANS THAT ALL LOW IS REQ`D TO BE | | PERMITTED, INSTALLED AND INSPECTED | | BEFORE CEILING IS INSTALLED. | | PLEASE NOTE, IF NOT INSTALLED BEFORE | | ROUGH, CONDUIT SHALL BE COMPLETE TO | | TELEPHONE ROOMS. | | | | 8)NOTE: PLEASE NOTE CIRCUITS ARE BEING | | LABELED AS 1-POLE ON PLANS, AS 2-POLE | | ON PANEL SCHEDULES AND YET ONLY TAKING | | ONE SPACE ON PANEL?? PLEASE CORRELATE. | | | | 9)NOTE: PLEASE NOTE REQ`MENTS FOR FAIR | | HOUSING. PLEASE SEE FHAR 24 CFR 100.205 | | DEVICE HEIGHTS/FHA MUST BE NOTED ON PLAN | | | | 10)NOTE: PLEASE NOTE OUTLET SPACING FOR | | KITCHEN COUNTERSPACE. PER 210-52-C-1. | | MISSING A FEW. | | | | 11)NOTE: PLEASE NOTE A UNIT "H" BEING | | SHOWN ON PLANS AND NO LAYOUT SUBMITTED. | | PLEASE ALSO NOTE A LAYOUT FOR A UNIT "G" | | ? PLEASE SUBMIT/ CORRELATE. | | | | 12)NOTE: PLEASE SUBMIT ALL PANEL SCHEDU- | | -LES. | | PLEASE ALSO NOTE PANELS ARE BEING SHOWN | | AS 24 CIR AND 30 CIR? PLEASE SEE | | PREVIOUS COMMENT ABOUT CIRCUITING NOT | | CORRELATING. | | | | 13)NOTE: PLEASE NOTE SD`S ARE INSIDE AND | | OUTSIDE ALL SLEEPING ROOMS. PLEASE NOTE | | ROOMS W/ CLOSETS AND/OR BATHS ARE CON- | | -SIDERED SLEEPING ROOMS. NFPA-72 2-2.1.1 | | .1. | | | | 14)NOTE: ALL LOAD CALCULATIONS ARE REQ`D | | TO BE SHOWN. PLEASE NOTE ALL CONTINUOUS | | LOADS AT 125%. PLEASE SEE 220-3,220-10, | | 220-11,220-13, 230-42, 215-3,, ETC. | | | | 15)NOTE: PLEASE SHOW LOCATIONS OF A/C | | COND UNITS ON ELECTRICAL PLANS. ROOF TOP | | ?? PLEASE NOTE DISC`S PER 440-11 AND | | GFI PER 210-63. | | | | 16)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | CIRCUITS FOR BEDROOM RECEPTS PER 210-12. | | | | 17)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW MAINS/PANELS/ BRKRS PER 110-9, | | 215-5. | | | | 18)NOTE: PLEASE NOTE, E-5 NOTES ALL | | WIRING TO BE MIN #12 AND PANEL SCHEDULE | | SHOWS #14 ON SOME? PLEASE CORRELATE OR | | NOTE ,, . | | | | 19)NOTE: PLEASE SHOW LOCATION OF SERVICE | | PLEASE NOTE GROUPING OF MAINS PER 230-72 | | IT IS NOTED TWO SEPARATE SERVICES ARE | | SHOWN ON RISER DIAGRAM. PLEASE NOTE | | THAT A SECOND SERVICE IS NOT PERMITTED | | PER 230-2. | | | | PLEASE NOTE THAT THERE MAY BE OTHER | | COMMENTS DUE TO CHANGES IN PLANS. | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2005-04-14 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2005-04-14 |
Time |
10:54 |
Rev Time |
0.05 |
Received By |
mamini |
Date |
2005-04-14 |
Time |
10:54 |
Sent To |
|
|
Notes |
2005-04-14 00:00:00 | PASSED: | | | | 1. UNDERGROUND UTILITIES AND SITE WORK | | PERMIT # 02120569 | | 2. PER REVIEW AND APPROVAL BY DEAN | | LAUDERMILK AND PLANNING AND ZONING DEPT. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
N |
Date |
2002-12-10 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2002-12-10 |
Time |
10:21 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2002-12-10 |
Time |
10:21 |
Sent To |
|
|
Notes |
2002-12-10 00:00:00 | N/A: | | 1. SEE PERMIT # 02120569 FOR CIVIL/ SITE | | WORK PERMIT. | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2002-09-16 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2002-09-16 |
Time |
13:33 |
Rev Time |
5.00 |
Received By |
mamini |
Date |
2002-09-16 |
Time |
13:33 |
Sent To |
|
|
Notes |
2002-09-16 00:00:00 | FAILED : | | 1. THE EXISTING TRAFFIC SIGN AS SHOWN AT | | NW CORNER MUST BE RELOCATED PER CITY | | ENGINEER' OFFICE DIRECTION, 659-8040 | | 2. THE H.C PARKING CURB CUT AS SHOWN AT | | SOUTH END OF THE BUILDING IS NOT NEEDED | | IF THE CURB CUT AT THE 14' ALLEY CAN BE | | USED, VERIFY. | | 3. THE TREE GREAT AS SHOWN AT SOUTH | | END OF THE BUILDING SEEMS TO BE IN | | CONFLICT WITH EXISTING CATCH BASIN AND | | PROPOSED 12" PVC ROOF DRAIN. PLEASE | | VERIFY. | | 4. IS THE EXISTING POWER POLE(NORTH END) | | IN CONFLICT WITH THE BUILDING FOUNDATION | | ?IF SO COORDINATION WITH UTILITY COMPANY | | FOR RELOCATION WOULD BE REQUIRED. | | 5. LOCATING THE DDCV AND RPZ IN THE SIDE | | WALK IS NOT ACCEPTABLE UNLESS APPROVED | | BY THE PUBLIC UTILITIES ENGINEEERING | | SERVICES. NOTE: FIRE SPRINKLER PLANS | | SHOWS DDCV AND CONNECTIONS IN DEFFERENT | | LOCATION, PLEASE COORDINATE. | | 6. A CURB CUT FOR THE PROPOSED ROLED OUT | | DUMPSTERS WILL BE REQUIRED. | | 7. SHEET 3 OF 4 SHOWS DETAILS FOR 90 DEG | | PARKING STALL STRIPPING, SHEET 2 OF 4 | | SHOWS 60 DEG. PARKING STALLS. | | 8. SHEET 3 OF 4 SHOWS DETAILS FOR | | EXFILTRATION TRENCH AND CONTROL | | STRUCTURE, ETC., PLEASE SHOW LOCATIONS, | | LENGTHS,ETC.,IF USED. | | 9. PLEASE SHOW DETAILS FOR INSTALLATION | | OF METER BOXES IN SIDEWALK.SEE ATTACHED | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
6 |
Status |
P |
Date |
2005-04-18 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-04-18 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-04-18 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-02-28 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-02-28 |
Time |
15:34 |
Sent To |
|
|
Notes |
2005-02-28 00:00:00 | REVISION DATED 01-25-05 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-07-14 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-07-14 |
Time |
14:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2003-03-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-07-13 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-03-13 |
Time |
15:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2003-01-24 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-01-24 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-01-24 |
Time |
10:29 |
Sent To |
|
|
Notes |
2003-01-24 00:00:00 | 1) BUILDING ADDRESS REQUIRED ON PROPER | | ELEVATION. | | | | 2) IF SECURITY DEVICES ARE PLANNED FOR | | THE GARAGE, HOW IS EXITING GOING TO | | BE PERFORMED FROM THE GARAGE. | | | | 3) A TWO-HOUR FIRE SEPARATION IS | | REQUIRED BETWEEN THE PARKING GARAGE | | AND OTHER PORTIONS OF THE BUILDING. | | | | 4) PLEASE SEE MECHANICAL REVIEWER | | COMMENTS. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-09-12 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-09-12 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-09-12 |
Time |
14:33 |
Sent To |
|
|
Notes |
2002-09-12 00:00:00 | 1) SEPARATE PLANS AND PERMITS REQUIRED | | FOR FIRE ALARM SYSTEM INSTALLATION. | | THE FIRE ALARM SYSTEM SHALL BE CLASS A | | OR FULLY ADDRESSABLE. | | | | 2) SEPARATE PLANS AND PERMITS REQUIRED | | FOR FIRE SPRINKLER SYSTEM INSTALLATION. | | THE HYDRAULIC CALCULATIONS LISTS | | PALM BEACH COUNTY FIRE RESCUE AS THE | | AHJ. IT SHOULD READ WEST PALM BEACH | | FIRE RESCUE. HOW DOES THE BACKFLOW | | DEVICE AND FIRE DEPARTMENT CONNECTION | | DO NOT INTERFERE WITH EXITING FROM | | THE STAIRTOWER. | | | | 3) IF FUTURE SECURITY DEVICES ARE | | INSTALLED FOR THE GARAGE HOW IS EXITING | | GOING TO BE ACCOMPLISHED. | | | | 4) ELECTRONIC SWITCHES WILL BE REQUIRED | | ON BACKFLOW DEVICE. SEE CIVIL DRAWING | | DETAILS. | | | | 5) DOORS # 9 SHALL BE AT LEAST 1 1/2 | | RATED SINCE A TWO HOUR FIRE SEPARATION | | IS REQUIRED BETWEEN THE GARAGE AND | | OTHER PORTIONS OF THE BUILDING. | | | | 6) AN EMERGENCY LIGHT FIXTURE IS | | LOCATED OUTSIDE OF THE STAIRTOWER ON | | PAGE E-1. | | | | 7) EXITS ARE TAKING PERSONS INTO A | | MORE HAZARDOUS AREA THE GARAGE FROM | | THE INTERIOR TENANT SPACES. | | | | 8) PLEASE INDICATE EXHAUST AIR CFM'S | | FOR PARKING GARAGE MECHANICAL | | VENTILATION. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
27 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-06-08 |
Time |
14:57 |
Sent To |
B |
|
Notes |
2005-06-08 00:00:00 | TO 'SH' DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
26 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-05-24 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-05-24 |
Time |
17:54 |
Sent To |
B |
|
Notes |
2005-05-24 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
25 |
Status |
N |
Date |
2005-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-14 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-14 |
Time |
09:53 |
Sent To |
|
|
Notes |
2005-04-21 00:00:00 | 4/21/05 TO "SHILL" DESK | 2005-04-14 00:00:00 | TO "COMM" BD#61 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
24 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-25 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-25 |
Time |
09:04 |
Sent To |
M |
|
Notes |
2005-03-25 00:00:00 | TO "PKRAUSS" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
23 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-31 |
Time |
11:34 |
Sent To |
|
|
Notes |
2005-01-31 00:00:00 | TO "COMM BD#30/REV. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
22 |
Status |
|
Date |
2004-11-24 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-11-23 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-11-19 |
Time |
11:52 |
Sent To |
|
|
Notes |
2004-11-19 00:00:00 | SENT TO SH DESK/RESTAMP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
21 |
Status |
N |
Date |
2004-07-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-26 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-26 |
Time |
15:03 |
Sent To |
B |
|
Notes |
2004-07-26 00:00:00 | TO SH DESK/SUBMITTAL | | DESIGN CLARIFICATIONS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
20 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-22 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-22 |
Time |
16:36 |
Sent To |
|
|
Notes |
2004-07-22 00:00:00 | TO COMM BD#31 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
19 |
Status |
N |
Date |
2004-07-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-15 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-15 |
Time |
16:03 |
Sent To |
B |
|
Notes |
2004-07-15 00:00:00 | TO SH DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
18 |
Status |
N |
Date |
2004-07-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-15 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-15 |
Time |
15:24 |
Sent To |
B |
|
Notes |
2004-07-15 00:00:00 | TO SH DESK/REV/ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
17 |
Status |
N |
Date |
2004-07-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-15 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-15 |
Time |
14:59 |
Sent To |
B |
|
Notes |
2004-07-15 00:00:00 | TO SH DESK/SUBMITTAL/DESIGN | | CLARIFICATION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
16 |
Status |
N |
Date |
2004-07-07 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-07 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-07 |
Time |
11:25 |
Sent To |
|
|
Notes |
2004-07-07 00:00:00 | TO COMM BD#5 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-23 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-23 |
Time |
15:02 |
Sent To |
B |
|
Notes |
2004-06-23 00:00:00 | TO SH DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2004-06-15 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-15 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-06-15 |
Time |
15:22 |
Sent To |
|
|
Notes |
2004-06-15 00:00:00 | TO COMM BD #33 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2004-05-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-18 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-18 |
Time |
08:30 |
Sent To |
B |
|
Notes |
2004-05-18 00:00:00 | TO SH DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2004-05-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-13 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-13 |
Time |
09:32 |
Sent To |
B |
|
Notes |
2004-05-13 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2004-04-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-16 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-16 |
Time |
14:52 |
Sent To |
B |
|
Notes |
2004-04-16 00:00:00 | TO HP DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-06 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-06 |
Time |
16:52 |
Sent To |
B |
|
Notes |
2004-04-06 00:00:00 | TO HP DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2004-04-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-06 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-06 |
Time |
16:49 |
Sent To |
B |
|
Notes |
2004-04-06 00:00:00 | TO SH DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2003-10-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-08 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-08 |
Time |
11:23 |
Sent To |
B |
|
Notes |
2003-10-08 00:00:00 | TO HP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2003-06-24 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-24 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-24 |
Time |
16:30 |
Sent To |
B |
|
Notes |
2003-06-24 00:00:00 | HP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2003-06-12 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-12 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-12 |
Time |
15:17 |
Sent To |
B |
|
Notes |
2003-06-12 00:00:00 | HP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-06-10 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-10 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-10 |
Time |
16:28 |
Sent To |
B |
|
Notes |
2003-06-10 00:00:00 | HP DESK, REVISION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-03 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-03 |
Time |
15:52 |
Sent To |
B |
|
Notes |
2003-04-03 00:00:00 | HP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-02-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-24 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-24 |
Time |
11:58 |
Sent To |
|
|
Notes |
2003-03-05 00:00:00 | TO #60 ON COMM BOARD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-02-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-18 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-18 |
Time |
11:54 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-01-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-16 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-16 |
Time |
17:31 |
Sent To |
|
|
Notes |
2003-01-16 00:00:00 | COM BOARD #45./WRT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2005-03-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-03-31 |
Time |
16:25 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2005-03-31 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
N |
Date |
2005-03-02 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-03-02 |
Time |
13:25 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2005-02-09 |
Time |
10:40 |
Sent To |
|
|
Notes |
2005-02-09 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.PLAN SHEET A-1 INDICATES AIR | | EXCHANGE UNIT.PLAN REFERENCES | | MECHANICAL DRAWING WHICH HAS NOT BEEN | | REVISED.PLEASE PROVIDE MECHANICAL | | REVISION CLARIFY "AIR EXCHANGE UNIT". | | IS THIS AN EXHAUST OR INTAKE OR BOTH? | | PLEASE NOTE, FRESH AIR INTAKES THAT | | FRONT A STREET OR PUBLIC WAY SHALL BE A | | MINIMUM OF 10FT REQUIRED TO THE | | CENTERLINE OF THE PUBLIC WAY. | | | | EXHAUST SHALL NOT DISCHARGE ONTO WALKWAY | | OR IN A MANNER THAT WILL CAUSE A | | NUISANCE PER 2001 FBC(M)401.6 | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2003-03-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-18 |
Time |
09:44 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2003-03-18 |
Time |
09:44 |
Sent To |
|
|
Notes |
2003-03-18 00:00:00 | SUBMITTAL LETTER TO FOLLOW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2003-03-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-10 |
Time |
11:35 |
Rev Time |
1.00 |
Received By |
pkrauss |
Date |
2003-03-10 |
Time |
11:35 |
Sent To |
|
|
Notes |
2003-03-10 00:00:00 | | | | | RESPONSE TO COMMENTS #4 RATED CHASE | | DETAIL ON PLAN SHEET A-5.DETAIL ONLY | | INDICATES 1 SIDE OF THE WALL.PLEASE | | PROVIDE DETAIL OF A PLAN VIEW AS TO THE | | ASSEMBLY AT THE CORNER OF THE SHAFT. | | | | 1.PLAN SHEET M-1, 16" X 12" FRESH AIR | | DUCT DOWN FROM ROOF TOP FOR FUTURE FRESH | | AIR CONNECTION SHALL BE IN A SHAFT | | INDEPENDANT FROM THE REFRIGERANT | | ENCLOSURE AS PER NFPA 90A 3-3.4.3. | | | | 2.PLAN SHEET M-2, UNIT A, FRESH AIR | | COMMENT INDICATES FRESH AIR DUCT IN 1 | | HR FIRE RATED CHASE WITH FIRE DAMPER AT | | THE CHASE PENETRATION SEE DETAIL. | | DETAIL DOES NOT SHOW A FIRE DAMPER. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2003-01-22 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-22 |
Time |
15:29 |
Rev Time |
2.15 |
Received By |
pkrauss |
Date |
2003-01-22 |
Time |
13:32 |
Sent To |
|
|
Notes |
2003-01-22 00:00:00 | DENIED: | | | | 1.PLAN SHEET M-1 DETAIL-CONDENSATE | | DRAIN TO SINK AND VENTS, CONDENSATE | | SHALL TERMINATE INTO STORM DRAIN OR | | INDEPENDENT DRYWELL. (SEE COMMENT #6, | | PLUMBING). | | | | 2.EXHAUST FOR THE GARAGE & DUMPSTER / | | RECYCLING AREA SHALL NOT DISCHARGE ONTO | | WALKWAY, 2001 FBC(M) 401.5.2. | | | | 3.CLARIFY GARAGE EXHAUST - NOTE ON | | PLAN SHEET M-5 EXHAUST FAN SCHEDULE | | CONTINUOUS OPERATION, WILL THIS BE TIED | | TO EMERGENCY POWER? | | | | 4.PLEASE CLARIFY PLAN SHEET M-2 FRESH | | AIR DOWN FROM ROOFTOP INTAKE IN FIRE | | RATED CHASE AND DETAIL OF THE AHU | | ON PLAN SHEET M-5 INDICATES A FIRE | | DAMPER AT THE FLOOR PENETRATION.2001 | | FBC(M) 607.4, FIRE DAMPERS CAN ONLY BE | | UTILIZED WHEN PENETRATING ONE FLOOR | | ONLY, DUCTS PENETRATING MORE THAN 1 | | FLOOR SHALL BE IN A RATED SHAFT.PLEASE | | PROVIDE DETAIL OF SHAFT & UL #. | | | | 4.DRYER EXHAUST SHALL BE NON-SCREENED | | WITH A BACKDRAFT DAMPER.2001 FBC(M) | | 504.4. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-10-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-10-07 |
Time |
12:18 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2002-10-07 |
Time |
12:00 |
Sent To |
|
|
Notes |
2002-10-07 00:00:00 | DENIED: | | | | NO MECHANICAL PLANS, ENERGY OR MANUAL J | | CALCULATIONS SUBMITTED FOR REVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
N |
Date |
2005-03-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-03-02 |
Time |
11:08 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2005-03-02 |
Time |
11:08 |
Sent To |
|
|
Notes |
2005-03-02 00:00:00 | NO PLUMBING REVISION NOTED THIS REVISION |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2004-08-07 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-08-07 |
Time |
11:47 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2004-08-07 |
Time |
11:47 |
Sent To |
|
|
Notes |
2004-08-07 00:00:00 | REVISION OK - NEW SANT. & WATER RISER | | DIAGRAMS, NEW LAYOUT FOR INSTA-HOT WATER | | HEATERS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2004-07-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-07-16 |
Time |
08:40 |
Rev Time |
2.00 |
Received By |
kstevens |
Date |
2004-07-15 |
Time |
15:26 |
Sent To |
|
|
Notes |
2004-07-16 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | A) FROM PREVIOUS REVIEW: NUMBER FROM THE | | PAST REVIEW WILL BE USED TO AVOID CONFU- | | SION. | | 5) SHT P-4 SANT. RISER DIAGRAM, SHOW THE | | STANDPIPES AND CLEANOUTS REQUIRED BY | | SECTIONS 1002.1, 802.4 AND 708.10. THE | | CLEANOUTS SHALL BE 4' ABOVE THE FLOOR | | FOR ACCESS. | | 6) SHT P-5 WATER RISER DIAGRAM SHALL RE- | | FLECT THE FLOOR PLAN, AND HOW THE WATER | | PIPING HAS BEEN INSTALLED. EXAMPLE FIRST | | UNIT ON SECOND FLOOR SHOWS LAV, WC, LINE | | TO KITCHEN SINK, TUB, THEN INSTA-HOT ON | | THE FLOOR PLAN BUT SHOWS INSTA-HOT, LAV, | | W/C, TUB, THEN KITCHEN SINK. PLEASE | | CORRELATE RISER DIAGRAM & FLOOR PLAN AND | | SHOW RISER AS A REFLECTION OF ACTUAL IN- | | STALLATION. SECTION 104.2.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-06-23 |
Time |
18:50 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2004-06-23 |
Time |
18:50 |
Sent To |
|
|
Notes |
2004-06-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | NEC-99 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) SHTS P-2 & P-3 INSTA HOTS NOT APPROV- | | ED IN CLOSETS. NEC 99 SECTION 422-17. | | 2) SUBMIT MANUF. SPECIFICATION SHEETS | | FOR INSTA-HOTS. SECTION 303.4. | | 3) SHTS P-2, P-3, & P-4 FLOOR DRAINS IN | | THE LAUNDRY SHALL BE 3" MINIMUM. SECTION | | 412.4. CHANGE RISER DIAGRAM TO REFLECT | | THIS ALSO. | | 4) SHT P-4 DEEP-SEAL TRAP OR TRAP PRIMER | | REQUIRED PER SECTION 1002.4. INDICATE | | ONE OR THE OTHER ON NOTE #16 PLUMBING | | SPECIFICATIONS. | | 5) SHT P-4 SANT. RISER DIAGRAM, SHOW THE | | STANDPIPES AND CLEAROUTS REQUIRED BY | | SECTIONS 1002.1, 802.4 AND 708.10. THE | | CLEANOUTS SHALL BE 4' ABOVE THE FLOOR | | FOR ACCESS. | | 6) SHT P-5 INSTA-HOTS ARE NOT SHOWN AS | | LOCATED IN THE SAME LOCATION AS THE | | WATER HEATERS WERE LOCATED. REVISE THE | | WATER RISER DIAGRAM TO REFLECT THE FLOOR | | PLAN FOR THE NEW LOCATION OF THE INSTA- | | HOTS. SHOW THE LOCATION OF THE REQUIRED | | WATER HAMMER ARRESTORS ON THE NEW RISER | | DIAGRAM. SECTION 104.2.1 | | 7) THE SIGNATURE OF THE ARCHITECT IS RE- | | QUIRED PER FAC 61G1-16.003 & FS 481.2055 | | INITIALS ARE NOT ACCEPTABLE. - PROVIDE | | A SIGNED, SEALED, DATED, AND NOTORIZED | | LETTER INDICATING THAT THIS IS YOUR LEG- | | AL SIGNATURE FOR OUR ARCHITECT/ENGINEER | | SIGNATURE FILE. - THIS HAS BEEN REQUEST- | | ED PREVIOUSLY PER DEWEY PALMER, ELECTRI- | | CAL PLAN REVIEWER. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-03-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-15 |
Time |
05:59 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2003-03-14 |
Time |
18:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-01-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-21 |
Time |
15:08 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2003-01-21 |
Time |
15:07 |
Sent To |
|
|
Notes |
2003-01-21 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) FROM PREVIOUS REVIEW: SHOW BACKING | | PER REQUIREMENT #6. | | 2) FROM PREVIOUS REVIEW: SHT P-1 PLUMB- | | ING NOTES #7, AIR CHAMBERS ARE NOT APP- | | ROVED. PLEASE DELETE REFERENCE. | | 3) FROM PREVIOUS REVIEW: SHT P-5 (NEW | | SHEET) SHOW REQUIRED WATER HAMMER ARRES- | | TORS PER SECTION 604.9. LOCATION TO BE | | NEAR THE FIXTURES IN AN "EFFECTIVE | | RANGE" NOT AT THE TOP OF THE DROPS IN | | THE CEILING. PER PDI-WH 201 AND MANUF. | | INSTALLATION INSTRUCTIONS. | | 4) FROM PREVIOUS REVIEW: SHT P-6 1/2 | | AREA OF VERTICAL WALLS NOT SHOWN IN | | CALCULATIONS AS REQUESTED. ALSO SHOW | | AREA BEING DRAINED AT EACH ROOF DRAIN. | | STORM WATER SHALL NOT DRAIN INTO THE | | SANITARY SYSTEM, BUT SHALL DRAIN INTO | | A CATCH BASIN OR STORM DRAIN ON SITE. | | PLEASE SHOW ALL HORIZONTAL STORM PIPING | | IN THE BLDG. AND SHOW ACCUMULATED SQUARE | | FOOTAGE AT EACH STORM RISER. | | 5) SHT P-6 STORM RISER WITH 3 DRAINS | | SHOWS PIPING STARTING AT 4" AND THEN | | REDUCING TO 3" AS IT PICKS UP THE 2ND | | ROOF DRAIN. PLEASE CLAIRFY. | | 6) FROM PREVIOUS REVIEW: PLEASE SUBMIT | | A CONDENSATE RISER DIAGRAM. CONDENSATE | | SHALL BE PIPED SAPARATELY OUT OF BDLG. | | AND TIE INTO STORM, CATCH BASIN, OR DRY- | | WELL. A RELIEF VENT IS REQUIRED AS COND. | | EXITS BLDG. | | 7) FROM PREVIOUS REVIEW: PLEASE SUBMIT | | RISERS FOR RELIEF VALVE DISCHARGE AND | | FOREMERGENCY PAN DRAIN LINES. SECTIONS | | 504.7.1 & 504.8.1. - T/P LINES SHALL NOT | | BE TRAPPED. INDICATE MATERIAL USED FOR | | RISERS. | | 8) FROM PREVIOUS REVIEW: PROVIDE A WATER | | HEATER DETAIL SHOWING COMPLIANCE WITH | | SECTION 607.3 THERMAL EXPANSION CONTROL. | | ALSO SEE SECIION 607.3.2. | | 9) FROM PREVIOUS REVIEW: SHT P-4 PLEASE | | SHOW DRAINAGE FIXTURE UNITS AS THEY | | ACCUMULATE IN THE SYSTEM IN THE HORIZON- | | TAL DRAIN. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-10-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-10-05 |
Time |
05:47 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-10-05 |
Time |
05:47 |
Sent To |
|
|
Notes |
2002-10-05 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FBC-2001 PLUMBING | | | | 1) SHT A-1 A DRINKING FOUNTAIN IS REQUI- | | RED PER TABLE 403.1 | | 2) SHTS A-2, A-3, & A-4, SHOW COMPLIANCE | | 0F FAIR HOUSING GUIDELINE REQUIREMENTS | | 1 THRU 7. INDICATE SPECIFICATION "A" OR | | "B" BATHROOMS FOR ALL UNITS. SHOW BACK- | | ING PER REQUIREMENT 6. SHOW CLEAR FLOOR | | SPACE FOR ALL KITCHEN AND BATHROOM FIX- | | TURES. INDICATE IF THERE WILL BE KNEE | | SPACE AT LAV'S OR NOT. IF NOT, (PARALLEL | | APPROACH), THE LAV WILL BE CENTERED IN | | THE 48" CLEAR FLOOR SPACE. | | 3) SHT A-5 A DRINKING FOUNTAIN SHALL BE | | REQUIRED IN OFFICE. TABLE 403.1 | | 4) SHT A-8 PLEASE PROVIDE CALCULATIONS | | FOR PRIMARY AND SECONDARY ROOF DRAINS | | PER SEC'S 1106 AND 1107. SHOW AREA FOR | | ALL VERTICAL WALLS ADDED TO CALCULATIONS | | 5) SHT P-1 PLUMBING NOTES #7, AIR CHAM- | | BERS ARE NOT APPROVED. PLEASE DELETE RE- | | FERENCE. | | 6) SHT P-4 PLUMBING SPECIFICATIONS #15 | | AIR CHAMBERS ARE NOT APPROVED, PLEASE | | DELETE REFERENCE. | | 7) PLEASE PROVIDE A WATER RISER DIAGRAM. | | SHOW ALL FIXTURES, AND PIPE SIZES. SHOW | | REQUIRED WATER HAMMER ARRESTORS PER SEC. | | 604.9. LOCATION TO BE NEAR THE FIXTURE | | IN AN "EFFECTIVE RANGE" NOT AT TOP OF | | RISER OR ON MAIN LINES ABOVE CEILING PER | | PDI-WH 201 AND MANUFACTURE INSTALLATION | | INSTRUCTIONS. | | 8) PLEASE SUBMIT A STORM RISER DIAGRAM. | | SHOW ALL PIPE SIZES AND SHOW SQUARE FEET | | AS IT ACCUMULATES IN SYSTEM. INDICATE | | WHERE STORM LINES WILL BE TIED IN OUT- | | SIDE OF BLDG. | | 9) PLEASE SUBMIT A CONDENSATE RISER DIA- | | GRAM. CONDENSATE SHALL BE PIPED SEPARAT- | | ELY OUT OF BLDG. AND TIE INTO STORM, | | CATCH BASIN, OR DRYWELL. A RELIEF VENT | | IS REQUIRED AS CONDENSATE EXITS BLDG. | | 10) PLEASE SUBMIT RISERS FOR RELIEF | | VALVE DISCHARGE, AND EMERGENCY PAN DRAIN | | LINES. SECS. 504.7.1 & 504.8.1 - T/P | | LINE SHALL NOT BE TRAPPED. INDICATE MAT- | | ERIAL USED FOR RISERS. | | 11) PROVIDE A WATER HEATER DETAIL SHOW- | | ING COMPLIANCE WITH 607.3 THERMAL EXPAN- | | SION CONTROL. ALSO SEE 607.3.2 | | 12) SHT PLEASE SHOW DRAINAGE FIXTURE | | UNITS AS THEY ACCUMULATE IN SYSTEM. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2004-07-13 |
|
|
Cont ID |
|
Sent By |
agiannio |
Date |
2004-07-13 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
agiannio |
Date |
2004-07-13 |
Time |
09:41 |
Sent To |
|
|
Notes |
2004-07-13 00:00:00 | 1.CANNOT FULLY REVIEW SINCE CHANGES ARE | | NOT INDICATED ON DRAWINGS. | | 2. AIR EXCHANGE IN DUMPSTER AREA CANNOT | | FACE SIDE PROPERTY LINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2003-04-16 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-04-16 00:00:00 | APPROVED BY SGRAHAM FOR AG |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2003-04-01 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2003-04-01 |
Time |
10:10 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-04-01 00:00:00 | OBTAIN DAC APPROVAL 3/31/03, PARKING | | APPROVED, | | | | OK ANTHEA | | VENTING TOWARDS NEIGHBORING PROPERTY IS | | PROHIBITED, EAST ELEVATION SEE ARTICLE | | IV SECT. 94-107(B) (2) | | | | ANTHEA |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2003-02-24 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2003-02-24 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-02-24 00:00:00 | 2ND CHECKLIST, NEED 25-SPACES |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2002-09-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-18 |
Time |
11:54 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-09-12 00:00:00 | 1. NOT ENOUGH PARKING | | 19 UNITS-19 SPACES | | 3000 SQ FT-6 SPACES | | TOTAL OF 25 SPACES NEEDED. | | (PAY IN PARKING FUND OR SEEK VARIANCE) | | 2. MOVE HC PARKING NORTH & UNCORPORATE | | RAMP INTO S/W. | | 3. NEED EVIDENCE OF (SECTION)33-46 (A) | | (4).STORIES AT S/W LEVEL SHALL BE NO | | LESS THAN 12 FEET IN HT FROM FINISHED | | FLOOR TO FINISHED CEILING AND SUCH | | STORIES SHALL NOT EXCEED TWENTY(20) FT | | IN HEIGHT FROM FINISHED FLOOR TO | | FINISHED FLOOR. |
|
|