Plan Review Details - Permit 02090111
Plan Review Stops For Permit 02090111
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-03 Cont ID  
Sent By jwitmer Date 2002-10-03 Time 10:43 Rev Time 1.25
Received By jwitmer Date 2002-10-03 Time 10:43 Sent To  
Notes
2002-10-03 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02090111
 ADDRESS: 287 VALENCIA RD
 CONT: TUSCANY HOMES
 TELL # (561)848-5280
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *****PROVISO*****
  
 MULLION INFORMATION TO BE SUPPLIED BY
 ROUGH BUCK INSPECTION!!!!!
 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-18 Cont ID  
Sent By pkrauss Date 2002-09-13 Time 07:57 Rev Time 2.25
Received By jwitmer Date 2002-09-18 Time 13:45 Sent To  
Notes
2002-09-18 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02090111
 ADD: 287 VALENCIA RD
 CONT: TUSCANY HOMES
 TEL: (561)848-5280
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 PLANS FAIL TO INDICATE THE TRANSITION
 FROM THE EXISTING FRAME WALL TO THE NEW
 ADDITION. IS THE ROOF FRAMING OF THE
 EXISTING STRUCTURE BEING HELD UP BY A
 GIRDER? IF SO DOES THIS CARRY THE ROOF
 JOIST, ARE THE ROOF JOIST THE SAME FRAM-
 ING MEMBER AS THE CEILING JOIST? WHAT
 LOADS ARE BEING TRANSFERED ( GRAVITY)
 WHERE, TO WHAT FRAMING MEMBERS, WHAT
 TYPE OF HOLD DOWNS ARE BEING USED? WHAT
 IS THE UPLIFT OF THE GIRDER HOLDING UP
 THE CONNECTION OF THE OLD AND NEW ROOF?
  
 2) HUGHES STRAPS ARE NO LONGER AVAILABLE
 1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY. PROVIDE CURRENT MANUFACTUR
 ER AND STRAP INFO!
  
 3)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 4) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
  
 5)1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 6)1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 7)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 8)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-03 Cont ID  
Sent By btrobaug Date 2002-10-03 Time 13:10 Rev Time 0.50
Received By btrobaug Date 2002-10-03 Time 12:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-09-12 Cont ID  
Sent By btrobaug Date 2002-09-12 Time 11:12 Rev Time 0.50
Received By btrobaug Date 2002-09-12 Time 08:56 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-09-13 Cont ID  
Sent By pkrauss Date 2002-09-13 Time 07:56 Rev Time 0.00
Received By pkrauss Date 2002-09-13 Time 07:46 Sent To B
Notes
2002-09-13 00:00:00NO MECHANICAL PLANS OR EQUIPMENT
 SUBMITTED FOR REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-09-13 Cont ID  
Sent By btrobaug Date 2002-09-12 Time 13:32 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
2002-09-13 00:00:00APPR FBC 2001 CODE,PES.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-09-10 Cont ID  
Sent By sgraham Date 2002-09-10 Time 09:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved