Plan Review Stops For Permit 02081828 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-01-29 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-01-29 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-01-29 |
Time |
09:40 |
Sent To |
|
|
Notes |
2003-01-29 00:00:00 | REV #2 DATED 12/11/02 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-10-16 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-10-16 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2002-10-11 |
Time |
14:26 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-09-09 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-09-09 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2002-09-09 |
Time |
11:14 |
Sent To |
|
|
Notes |
2002-09-09 00:00:00 | SHOW THE FIRE RATED MIXED OCCUPACCY | | SEPARATION IN ACCORDANCE WITH FBC | | 704.1.1 BETWEEN THE OFFICE AREA ON THE | | EAST SIDE AND THE WAREHOUSE ON THE | | WEST.GROUP B AND GROUP S, INCLUDING | | THE DOORS. | | | | WHAT IS THE STRUCTURE "EXISTING SHED TO | | REMAIN" SHOWN ON SHEET A 2.1 AND | | ELSEWHERE? | | | | ARE THE OPENINGS TO BE CUT IN THE | | EXISTING SEPARATION WALLS TO RECEIVE | | ANY KIND OF HEADER OR LINTEL?WILL THE | | OPENING GO TO THE DECK ABOVE?PLEASE | | CLARIFY. | | | | THE ENERGY CODE CALCULATIONS ARE NOT | | SIGNED AND SEALED AND THE PLANS DO NOT | | REFLECT THE INSULATION VALUES.SEE FBC | | 13-103. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-01-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-30 |
Time |
06:23 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-01-30 |
Time |
06:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-01-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-23 |
Time |
07:53 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-01-23 |
Time |
07:53 |
Sent To |
|
|
Notes |
2003-01-23 00:00:00 | ************* UNSAT ************* | | | | 1)NOTE: PLEASE NOTE, E-3.0 DOES NOT | | SHOW ANY REVISIONS? PLEASE CLARIFY. | | PLEASE SHOW AS CLOUDS/TRIANGLES. | | | | PLEASE SUBMIT THE ABOVE INFORMAITON FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-10-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-10-08 |
Time |
19:45 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2002-10-08 |
Time |
19:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-09-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-09-06 |
Time |
11:21 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2002-09-06 |
Time |
11:10 |
Sent To |
|
|
Notes |
2002-09-06 00:00:00 | ***************** UNSAT *************** | | | | 1)NOTE: PLEASE NOTE PLANS ARE NOT | | COMPLETED FOR REVIEW. PANEL SCHEDULES | | ETC. | | | | 2)NOTE: PLEASE NOTE THAT ELECTRICAL | | POWER PLANS AND RISER DIAGRAM DO NOT | | CORRELATE. | | | | 3)NOTE: PLEASE NOTE SOME EQUIPMENT | | GROUNDING CONDUCTORS SHOWN BETWEEN | | GUTTER(S)/METER AND MAIN DISC`S. THIS | | IS PARALLELING THE NEUTRAL WHICH IS NOT | | PERMITTED. PLEASE SEE 250-24. | | | | 4)NOTE: PLEASE CLARIFY CONDUCTORS ON | | RISER DIAGRAM. SOME SHOWN AS ALUM AND | | OTHERS AT COPPER? PLEASE NOTE AMPERAGE | | RATINGS OF ALUM CONDUCTORS PER 310-16 | | SOME AREAS ON RISER MISSING CONDUCTORS/ | | SIZES SHOWN. | | | | | | 5)NOTE: PLEASE NOTE POWER PLAN SHOWS | | A NEW SERVICE AT ONE LOCATION AND ALSO | | SHOWS SERVICE EQUIPMENT COMING FROM | | EXISTING PANELS THAT ARE NOT SHOWN AS | | NEW?? PLEASE SEE PLASN AND CORRELATE. | | | | 6)NOTE: PLEASE CLARIFY METHOD(S) FOR | | GROUNDING ELECTRODES?? 250-50 | | | | 7)NOTE: PLEASE CLARIFY LOAD CALCS | | SHOWING "TWO PHASE"?? | | | | 8)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | PLEASE NOTE MAINS/PANELS/BRKRS ALL | | MUST BE RATED FOR THE AVAILABLE FAULT | | CURRENT. 110-9 | | | | PLEASE NOTE THAT WHEN PLANS ARE | | COMPLETED, A FULL REVIEW CAN ONLY THEN | | TAKE PLACE. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 | | | | | | PLEASE NOTE PER FS/FAC 471.025/ 61G15- | | 23.002 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2003-02-03 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-02-03 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-02-03 |
Time |
13:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-10-02 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-10-02 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-10-02 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-08-28 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-08-28 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-08-28 |
Time |
11:46 |
Sent To |
|
|
Notes |
2002-08-28 00:00:00 | 1) IS THE EXISTING BUILDING FIRE | | SPRINKLER PROTECTED. | | | | 2) PLEASE INDICATE ANY FIRE SEPARATIONS | | BETWEEN MIXED OCCUPANCIES AND BETWEEN | | TENANTS. | | | | 3) SINGLE TENANT OR MULTIPLE TENANTS. | | | | 4) PLEASE PROVIDE INTERIOR FINISH | | CLASSIFICATION INFORMATION FOR WALLS | | AND CEILINGS. | | | | 5) PLEASE INDICATE WHAT THE STORAGE | | AREAS WILL BE USED FOR. | | | | 6) PLEASE PROVIDE OCCUPANT LOADS. | | | | 7) FIRE ALARM EQUIPMENT NEW OR EXISTING. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-04-25 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-25 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-25 |
Time |
09:24 |
Sent To |
P |
|
Notes |
2003-04-25 00:00:00 | KSTEVENS DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-02-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-02-20 |
Time |
11:26 |
Sent To |
M |
|
Notes |
2003-02-20 00:00:00 | TO MECH INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-01-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-02 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-01-02 |
Time |
15:11 |
Sent To |
|
|
Notes |
2003-01-02 00:00:00 | TO COMM BOARD #15 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2003-02-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-02-24 |
Time |
13:00 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2003-02-24 |
Time |
09:18 |
Sent To |
|
|
Notes |
2003-02-24 00:00:00 | MECHANICAL PERMIT 02081834 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-01-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
11:26 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2003-01-17 |
Time |
09:47 |
Sent To |
|
|
Notes |
2003-01-17 00:00:00 | PROVISO: | | | | PLEASE PROVIDE SUBMITTAL OF CURBS FOR | | THE "RELOCATED" RTU'S (MINIMUM OF 8" | | FROM THE ROOF SURFACE 2001 FBC 1511.7). | | PROVIDE OUTSIDE AIR CALCULATIONS AS PER | | 2001 FBC(M) TABLE 403.3 OR ASHRAE 62-89. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-10-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-10-07 |
Time |
18:36 |
Rev Time |
1.00 |
Received By |
hmoser |
Date |
2002-10-07 |
Time |
18:36 |
Sent To |
|
|
Notes |
2002-10-07 00:00:00 | PASS/PROVISO | | 1) REFER TO SECTION 601.4 BALANCED | | RETURN AIR FBC.(M)2001 | | 2) REFER TO SECTION 606 SMOKE DETECTION | | SYSTEMS CONTROL FBC(M)2001. | | WITH HORN & STROBE | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8390 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-09-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-09-16 |
Time |
12:58 |
Rev Time |
1.00 |
Received By |
hmoser |
Date |
2002-09-16 |
Time |
12:58 |
Sent To |
|
|
Notes |
2002-09-16 00:00:00 | PLAN DENIED | | 1) NO FAN SCHEDULE FOR BATH EXHAUST | | 2) NO EQUIPMENT SCHEDULE | | 3) MECHANICAL PLANS PAGE 1.0 AND 1.1 | | DO NOT MATCH | | 4) NEED MORE INFORMATION ON PLANS | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2003-04-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-04-26 |
Time |
08:38 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-04-26 |
Time |
08:36 |
Sent To |
|
|
Notes |
2003-04-26 00:00:00 | REVISION OK - SHOWING ORIGINAL GRAB BARS | | IN TOILET ROOMS - NEW CABINET IN LOUNGE | | SINK TO COMPLY WITH 11-4.24 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-01-29 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-25 |
Time |
09:24 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-01-29 |
Time |
10:28 |
Sent To |
|
|
Notes |
2003-01-29 00:00:00 | REVISION OK - TOILET ROOM IS EXISTING - | | THEY WERE GOING TO REMOVE IT BUT NOW | | THEY WILL NOT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2003-01-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-18 |
Time |
17:01 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-01-18 |
Time |
17:00 |
Sent To |
|
|
Notes |
2003-01-18 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) SHT A2.1 NEW TOILET ROOM DOES NOT | | MEET CODE REQUIREMENTS OF 11-4.22, | | 11-4-22.3 - AN UNOBSTRUCTED TURNING | | SPACE COMPLYING WITH 11-4.2.3 SHALL BE | | PROVIDED. TOILET SHALL NOT OBSTRUCT | | TURNING CIRCLE. | | 2) PLEASE PROVIDE A SANITARY RISER DIA- | | GRAM AND A WATER RISER DIAGRAM FOR NEW | | TOILET ROOM. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-10-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-10-17 |
Time |
14:56 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2002-10-17 |
Time |
14:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-09-16 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-10-16 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-09-16 |
Time |
17:06 |
Sent To |
|
|
Notes |
2002-09-16 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FBC-2001 PLUMBING | | | | 1) 20 PERCENT OVER CONTRACT AMOUNT SHALL | | BE SPENT ON ACCESSIBLE ALTERATIONS FOR | | PRIMARY FUNCTIONS. 11-4.1.6(2) PLEASE | | PROVIDE INFORMATION SHOWING HOW THE | | $40,522.40 WILL BE SPENT FOR ACCESSIBLE | | ALTERATIONS. | | 2) SHT SP-1 SHOWS OFFICE SPACE FOR JFD'S | | WAREHOUSE AND WAREHOUSE #2 BUT IT'S NOT | | SHOWN ON FLOOR PLAN. PLEASE CLAIRFY. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|