Plan Review Details - Permit 02081384
Plan Review Stops For Permit 02081384 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-06-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-06-16 |
Time |
14:17 |
Rev Time |
0.45 |
Received By |
jwitmer |
Date |
2003-06-16 |
Time |
14:17 |
Sent To |
|
|
Notes |
2003-06-16 00:00:00 | MASTER PLAN UPDATE TRUSS ANCHOR SCHEDULE | | TO REFLECT 1609.4.3 LOAD REDUCTIONS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2002-09-23 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-30 |
Time |
15:28 |
Rev Time |
0.05 |
Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-09-23 00:00:00 | APPROVED PER JIM WITMER 9-19-02 ON | | PERMIT 02081383 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-09-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-09-04 |
Time |
16:59 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2002-09-04 |
Time |
16:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2002-08-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-08-29 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-08-29 |
Time |
13:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-05-30 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-05-30 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-05-30 |
Time |
15:28 |
Sent To |
B |
|
Notes |
2003-05-30 00:00:00 | JW DESK |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2002-09-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-09-23 |
Time |
11:41 |
Rev Time |
0.05 |
Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-09-23 00:00:00 | LETTER SUBMITTED IN RESPONSE TO H. MOSER | | PROVISO NOTES. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-09-20 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-09-20 |
Time |
14:22 |
Rev Time |
1.00 |
Received By |
hmoser |
Date |
2002-09-20 |
Time |
14:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-09-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-09-07 |
Time |
13:10 |
Rev Time |
1.00 |
Received By |
hmoser |
Date |
2002-09-07 |
Time |
13:10 |
Sent To |
|
|
Notes |
2002-09-07 00:00:00 | PASS PRIVISO | | FOR UNITS C,CR,B,BR,A,AR, | | 1) REFER TO SECTION 402.3.1 BATHROOM | | EXHAUST FBC.2001 | | 2) NEED FRESH AIR CALCULATIONS FOR ROUGH | | INSPECTION | | 3) CONDENSATE DRAIN MUST TERMINATE MIN. | | 12IN.FROM BUILDING 1503.4.4 FBC.2001 | | 4) NEED PRESSURE TEST ON REF.LINES | | 150 PSI 1108.1 FBC.2001 | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-08-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-08-31 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-08-31 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
|