Plan Review Details - Permit 02081324
Plan Review Stops For Permit 02081324
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-30 Cont ID  
Sent By csiegber Date 2003-10-27 Time 15:07 Rev Time 1.00
Received By jwitmer Date 2002-10-30 Time 07:14 Sent To  
Notes
2002-10-30 00:00:00 
 *** ISSUED MASTER***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02081324
 ADDRESS: LIBERTY BAY
 MASTER "C"
 CONT: HOME DYNAMICS
 TELL # (954) 275-8569
 VICTOR GONZALEZ
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-08 Cont ID  
Sent By btrobaug Date 2002-10-28 Time 11:22 Rev Time 1.00
Received By jwitmer Date 2002-09-08 Time 13:14 Sent To  
Notes
2002-09-08 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02081324
 ADD: *****LIBERTY ISLES*****
 ****MODEL "C"****
 CONT: HOME DYNAMICS
 TEL: (954)275-8569
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) SHEET A-2 NOTE: MONOLITHIC CONCRETE
 FOUNDATION WITHOUT HOOKBARS DESIGN BY
 RATIONAL ANAYLIS, WHAT IS THE MINIMUM
 DOWEL EMBEDDMENT DEPTH WITH NO HOOKS?
 GARGE SECTION STEMWALL CONT DO THE
 DOWEL BARS REQUIRE EXTRA EMBEDDMENT TO
 REACH THE FOUNDATION PORTION OF THE
 STEMWALL DESIGN?
  
 2) DESIGN NOTES SHEET A-3 INDICATE 130
 MPH, WE ARE LOCATED IN A 140 MPH WIND
 ZONE. ALSO WIND LOADS AS PER CHAPTER 16,
 AND ASCE 7-98.
  
 3) TABLE 2306.1 PALM BEACH COUNTY
 AMENDMENTS
 ROOF SHEATHING NAILING REQUIREMENTS
  
 ZONE 1 & 28D COMMON
 6" EDGES & 6" INTERMEDIATES
  
 ZONE 38DCOMMON
 4" EDGES & 6" INTERMEDIATES
  
 4) PROVIDE KEY PLAN FOR THE INSTALLATION
  
 SCHEDULE/ STORM SHUTTERS.
 JIM WITMER
 PLAN REVIEW
 (561)659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-28 Cont ID  
Sent By btrobaug Date 2002-10-28 Time 11:22 Rev Time 0.50
Received By btrobaug Date 2002-10-28 Time 11:06 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-08-29 Cont ID  
Sent By btrobaug Date 2002-08-28 Time 14:46 Rev Time 0.50
Received By btrobaug Date 2002-08-28 Time 13:15 Sent To R
Notes
2002-08-28 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 1} PLEASE NOTE THERE MUST BE A GFI
 INSTALLED IN THE FRONT OF THE RESIDENCE
 PER 210-52(E).
  
 2} PLEASE CLARIFY THE #6 GROUND SHOWN
 BEING RAN WITH THE FPL SERVICE.
  
 3} THE SMOKE DETECTOR IN THE HALLWAY
 UPSTAIRS IS TO BE LOCATED 5" FROM
 RETURN AIR(ALSO 3' FROM BATHS, KITCHENS
 AND AIR DUCTS PER NFPA-72,CHAPTER
 8,1999 EDT.
  
 PLEASE REVISE PLANS AND RESUBMIT FOR
 REVIEW.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-27 Cont ID  
Sent By csiegber Date 2003-10-27 Time 15:07 Rev Time 0.00
Received By csiegber Date 2003-10-27 Time 15:07 Sent To B
Notes
2003-10-27 00:00:00TO JW DESK/REV/MASTERED

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-01-29 Cont ID  
Sent By pkrauss Date 2003-01-29 Time 12:53 Rev Time 0.30
Received By pkrauss Date 2003-01-29 Time 12:27 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2003-01-24 Cont ID  
Sent By pkrauss Date 2003-01-24 Time 12:43 Rev Time 0.30
Received By pkrauss Date 2003-01-24 Time 12:43 Sent To  
Notes
2003-01-24 00:00:00REVISION TO MASTER DENIED.PLEASE
 ADDRESS THE FOLLOWING INFORMATION.
  
 1.PLANS SUBMITTED WITH THE ORIGINAL
 APPROVED SET WERE SIGNED & SEALED BY
 ARCHITECT.REVISIONS NEED TO BE SIGNED,
 SEALED, AND DATED BY ARCHITECT (PER
 CHAPTER 481 OF THE FLORIDA STATUTES).
  
 2.PLANS ARE NOT SPECIFIC.NOTES ON
 PLAN DUCTWORK TRUNK LINE & DROP LOCATION
 MAY VARY FROM PLAN, GRILLE SIZE OR FLEX
 MAY VARY TO EQUAL OR LARGER SIZES,
 TRIANGLE OR SQUARE BOX.AS PER 2001
 FBC CHAPTER 1 AMENDMENTS SECTION 104.2.1
 DRAWINGS SHALL BE SPECIFIC, & THE
 TECHNICAL CODES SHALL NOT BE CITED AS A
 WHOLE OR IN PART NOR SHALL THE TERM
 "LEGAL" OR ITS EQUIVALENT BE USED AS
 SUBSITITUTE FOR SPECIFIC INFORMATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-10-26 Cont ID  
Sent By jleech Date 2002-10-26 Time 06:25 Rev Time 0.33
Received By jleech Date 2002-10-26 Time 06:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-08-24 Cont ID  
Sent By hmoser Date 2002-08-24 Time 07:11 Rev Time 0.50
Received By hmoser Date 2002-08-24 Time 07:11 Sent To  
Notes
2002-08-24 00:00:00PLAN DENIED
 1) CAN NOT GO THROUGH WALL ON "O" LOT
 LINE SIDE OF HOUSE WITH DRYER WALL
 CAP.
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-10-26 Cont ID  
Sent By jleech Date 2002-10-26 Time 06:26 Rev Time 0.25
Received By jleech Date 2002-10-26 Time 06:25 Sent To  
Notes
2002-10-26 00:00:00RE-STAMP

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-20 Cont ID  
Sent By jleech Date 2002-08-20 Time 17:02 Rev Time 0.33
Received By jleech Date 2002-08-20 Time 17:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2002-10-30 Cont ID  
Sent By jwitmer Date 2002-10-30 Time 07:14 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***