Plan Review Details - Permit 02081323
Plan Review Stops For Permit 02081323
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-30 Cont ID  
Sent By csiegber Date 2003-10-27 Time 15:06 Rev Time 1.00
Received By jwitmer Date 2002-10-30 Time 10:10 Sent To  
Notes
2002-10-30 00:00:00 
  
 *** ISSUED MASTER***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02081323
 ADDRESS: LIBERTY ISLES
 MASTER "B"
 CONT: HOME DYNAMICS
 VICTOR GONZALEZ
 TELL # (954)275-8569
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-08 Cont ID  
Sent By btrobaug Date 2002-10-28 Time 13:48 Rev Time 1.00
Received By jwitmer Date 2002-09-08 Time 12:20 Sent To  
Notes
2002-09-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02081323
 ADD:*****LIBERTY ISLES*****
 ****MASTER "B"****
 CONT: HOME DYNAMICS VICTOR GONZALEZ
 TEL: (954)275-8569
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) SHEET A-2 NOTE: MONOLITHIC CONCRETE
 FOUNDATION WITHOUT HOOKBARS DESIGNED BY
 RATIONAL ANAYLSIS, WHAT IS THE MINIMUM
 DOWEL EMBEDDMENT DEPTH WITH NO HOOK?
 GARAGE SECTION STEMWALL CONSTRUCTION,
 DO THE DOWELS REQUIRE EXTRA EMBEDDMENT
 TO REACH THE FOUNDATION PORTION OF THE
 STEMWALL CONSTRUCTION?
  
 2) 2312.2 SHEARWALL WOOD FRAME SHEAR
 WALLS OR SEGMENTS INDICATE, OPENINGS
 IN SHEAR WALLS SHALL BE SHEATHED WITH
 STRUCTURAL SHEATHING2312.2.2
  
 3) SHEET A-3 DESIGN NOTE INDICATES WIND
 ZONE OF 130 SHOULD READ 140 MPH. ALSO
 ASCE &-98.
  
 4) SHEET A-4 MEAN ROOF HEIGHT < 25'
 ROOF SHEATHING NAILING REQUIREMENT
 PALM BEACH COUNTY AMENDMENTS!!!!!
 ZONES 1 & 2 8D
 6" EDGES & 6" INTERMEDIATES
 ZONE 3
 4" EDGES & 6" INTERMEDIATES
  
 5) PROVIDE KEY PLAN FOR INSTALATION
 SCHEDULE/ STORM SHUTTERS.
 JIM WITMER
 PLAN REVIEW
 (561)659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-28 Cont ID  
Sent By btrobaug Date 2002-10-28 Time 13:48 Rev Time 0.50
Received By btrobaug Date 2002-10-28 Time 11:35 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-08-28 Cont ID  
Sent By btrobaug Date 2002-08-28 Time 12:05 Rev Time 0.00
Received By btrobaug Date 2002-08-28 Time 10:30 Sent To R
Notes
2002-08-28 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THAT THE #6 GROUND BETWEEN
 THE METER AND THE MAIN DISCONNECT
 CREATES A PARALLEL PATH TO THE
 GROUNDING ELECTRODE SYSTEM WITH THE
 NEUTRAL.ALSO CLARIFY THE #6 GROUND
 SHOWN BEING RAN WITH FPL SERVICE.
  
 THE SMOKE DETECTOR SHOWN IN THE HALLWAY
 UPSTAIRS IS TO BE LOCATED AT LEAST
 5'FROM RETURN AIR DUCTS.
  
 REVISE THE PLANS AND RESUBMIT FOR
 REVIEW.
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-27 Cont ID  
Sent By csiegber Date 2003-10-27 Time 15:03 Rev Time 0.00
Received By csiegber Date 2003-10-27 Time 15:03 Sent To B
Notes
2003-10-27 00:00:00TO JW DESK/REV/MASTERED

Review Stop M MECHANICAL (A/C)
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pkrauss Date 2003-11-14 Time 09:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2003-01-24 Cont ID  
Sent By csiegber Date 2003-10-27 Time 15:04 Rev Time 0.30
Received By pkrauss Date 2003-01-24 Time 11:44 Sent To  
Notes
2003-01-24 00:00:00REVISION TO MASTER DENIED.PLEASE
 ADDRESS THE FOLLOWING INFORMATION.
  
 1.PLANS SUBMITTED WITH THE ORIGINAL
 APPROVED SET WERE SIGNED & SEALED BY
 ARCHITECT.REVISIONS NEED TO BE SIGNED,
 SEALED, AND DATED BY ARCHITECT (PER
 CHAPTER 481 OF THE FLORIDA STATUTES).
  
 2.PLANS ARE NOT SPECIFIC.NOTES ON
 PLAN DUCTWORK TRUNK LINE & DROP LOCATION
 MAY VARY FROM PLAN, GRILLE SIZE OR FLEX
 MAY VARY TO EQUAL OR LARGER SIZES,
 TRIANGLE OR SQUARE BOX.AS PER 2001
 FBC CHAPTER 1 AMENDMENTS SECTION 104.2.1
 DRAWINGS SHALL BE SPECIFIC, & THE
 TECHNICAL CODES SHALL NOT BE CITED AS A
 WHOLE OR IN PART NOR SHALL THE TERM
 "LEGAL" OR ITS EQUIVALENT BE USED AS A
 SUBSITITUTE FOR SPECIFIC INFORMATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-10-26 Cont ID  
Sent By jleech Date 2002-10-26 Time 07:35 Rev Time 0.33
Received By jleech Date 2002-10-26 Time 07:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-24 Cont ID  
Sent By hmoser Date 2002-08-24 Time 07:50 Rev Time 0.50
Received By hmoser Date 2002-08-24 Time 07:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-10-26 Cont ID  
Sent By jleech Date 2002-10-26 Time 07:36 Rev Time 0.25
Received By jleech Date 2002-10-26 Time 07:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-20 Cont ID  
Sent By jleech Date 2002-08-20 Time 18:33 Rev Time 0.33
Received By jleech Date 2002-08-20 Time 18:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2002-10-30 Cont ID  
Sent By jwitmer Date 2002-10-30 Time 10:09 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***