Plan Review Details - Permit 02081209
Plan Review Stops For Permit 02081209
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-21 Cont ID  
Sent By jwitmer Date 2002-10-21 Time 14:41 Rev Time 1.25
Received By jwitmer Date 2002-10-21 Time 14:41 Sent To  
Notes
2002-10-21 00:00:00 
  
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02081209
 ADDRESS: 5902 N SAN ANDROS
 CONT: ENGLES HOMES
 TELL # (561)968-5671
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-12 Cont ID  
Sent By jwitmer Date 2002-09-12 Time 15:59 Rev Time 3.00
Received By jwitmer Date 2002-09-12 Time 15:59 Sent To  
Notes
2002-09-12 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02081209
 ADD: 5902 N SAN ANDROS
 CONT: ENGLES HOMES
 TEL: (561)968-5671
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PRODUCT APPROVALS WITH EXPIRED DATES:
 A) ALUMINIUM SINGLE HUNG WINDOWS
 99-0324.04
 B) SERIES 6000 ALUMINIUM FIXED WINDOWS
 98-0928.02
 C) ALUMINIUM TUBE MULLIONS
 99-0223.04
  
 2)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 3)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 4) PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION, CITY CODE REQUIRES
 AN ADDITIONAL 6".
  
 5)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-09-10 Cont ID  
Sent By dpalmer Date 2002-09-10 Time 06:22 Rev Time 0.25
Received By dpalmer Date 2002-09-10 Time 06:22 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-09-07 Cont ID  
Sent By jleech Date 2002-09-07 Time 11:30 Rev Time 0.50
Received By jleech Date 2002-09-07 Time 11:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-24 Cont ID  
Sent By jleech Date 2002-08-24 Time 13:00 Rev Time 0.33
Received By jleech Date 2002-08-24 Time 13:00 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-09-12 Cont ID  
Sent By jwitmer Date 2002-09-12 Time 15:59 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-19 Cont ID  
Sent By sgraham Date 2002-08-19 Time 09:06 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***