Plan Review Details - Permit 02081115
Plan Review Stops For Permit 02081115
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-09-27 Cont ID  
Sent By jwitmer Date 2002-09-27 Time 10:56 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-09-27 00:00:00 
 ***** ISSUED PERMIT*****
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02081115
 ADDRESS: 6397 CROWN ISLAND COVE
 CONT: M/I HOMES
 TELL # (561) 471-3440
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *****PROVISO*****
  
 FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 SOILS ENGINEERING REPORT IS TO BE
 PART OF THE PLAN REVIEW PROCESS INDI-
 CATING THE MINIMUM SAFE BEARING OF THE
 SOILS. ALL SOILS REPORTS ARE TO HAVE THE
 FOLLOWING INFORMATION:
 A) A 15 FT STANDARD PENETRATION TEST
 B) SOILS PROFILE OF THE SUPPLEMENTAL
 10 FT AUGERS TO VERIFY UNIFORMITY
 OF MATERIALS.
 C) THE MINIMUM SAFE BEARING VALUE OF
 THE SOILS.
 D) IF DELETERIOUS MATERIALS, MUST BE RE
 MOVED, THE REPORT SHALL CONTAIN DETAILED
 SPECIFICATIONS FOR REMOVAL, DISPOSAL
 CLASSIFICATION OF NEW FILL MATERIALS,
 TEST CONTROLS FOR THE BACK FILLING
 E) IF PI;LING IS RECOOMMENDED
 F) IF ADDITIONAL FILL REQUIRED WITHIN
 THE BOUNDRY OF THE STRUCTURE, THEN PLACE
 MENT AND THE COMPACTION OF THE NEW FILL
 MATERIALS, AND DENSITY REPORTS!

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-02-21 Cont ID  
Sent By btrobaug Date 2003-02-21 Time 14:00 Rev Time 0.50
Received By btrobaug Date 2003-02-21 Time 13:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-02-21 Cont ID  
Sent By btrobaug Date 2003-02-21 Time 13:49 Rev Time 0.50
Received By btrobaug Date 2003-02-21 Time 13:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-09-26 Cont ID  
Sent By dpalmer Date 2002-09-26 Time 11:18 Rev Time 0.25
Received By dpalmer Date 2002-09-26 Time 11:18 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-09-10 Cont ID  
Sent By dpalmer Date 2002-09-10 Time 05:09 Rev Time 0.50
Received By dpalmer Date 2002-09-12 Time 06:04 Sent To B
Notes
2002-09-10 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT ALL HANDWRITTEN
 CHANGES ON PLANS MUST BE RE-PRINTED
 AND SIGNED, DATED AND SEALED BY ARCH OF
 RECORD. PLEASE NOTE, EACH CHANGE MAY BE
 SIGNED AND DATED ALSO. 481.221 FS/FAC.
  
 2)NOTE: PLEASE ALSO NOTE, IT APPEARS
 THAT THERE A COUPLE OF REQ`D NEC ITEMS
 MISSING ONPLANS THAT WERE DRAWN IN.
  
 NOTE: MISSING FROUNT RECEPT. 210-52E
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMAITON FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-09-07 Cont ID  
Sent By jleech Date 2002-09-07 Time 09:12 Rev Time 0.50
Received By jleech Date 2002-09-07 Time 09:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-24 Cont ID  
Sent By jleech Date 2002-08-24 Time 10:56 Rev Time 0.33
Received By jleech Date 2002-08-24 Time 10:55 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2002-09-27 Cont ID  
Sent By jwitmer Date 2002-09-27 Time 10:56 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-09-12 Cont ID  
Sent By jwitmer Date 2002-09-12 Time 06:35 Rev Time 3.00
Received By jwitmer Date 2002-09-12 Time 06:35 Sent To  
Notes
2002-09-12 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02081115
 ADD: 6397 CROWN ISLAND COVE
 CONT: M/I HOMES
 TEL: (561)471-3440
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
  
 2)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST. MISSING REPORT:
 A) EXPIRED HORIZONTAL ROLLING WINDOW
  
 3) WHITE OUT ON PLANS, ARCHITECT DOESN'T
 INDICATE CHANGES MADE(SIGNATURE) NOR
 LETTER.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-19 Cont ID  
Sent By sgraham Date 2002-08-19 Time 09:06 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***