Plan Review Stops For Permit 02081062 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-01-29 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2003-01-29 |
Time |
15:46 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-10-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-28 |
Time |
09:43 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-08-22 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-08-22 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2002-08-22 |
Time |
10:25 |
Sent To |
|
|
Notes |
2002-08-22 00:00:00 | SHEET 4 OF 5.IF THE TERM "INSTALL | | CONTACTS ON DOORS" IS INTENDED TO BE A | | HOLD OPEN DEVICE FOR THE STAIR SHAFT | | DOORS, PROVIDE SPECIFIC DESIGN | | INFORMATION DEMONSTRATING COMPLIANCE | | WITH FBC 705.1.3.2.3 AND THE APPLICABLE | | PORTIONS OF FBC 1012.1.11. ALSO, PROVIDE | | DOCUMENTATION THAT THE LISTING FOR THE | | EXISTING DOOR MAY BE ALTERED IN THIS | | FASHION | | | | WHAT CONTROLS OR PRECAUTIONS FOR THE | | CUTTING OF THE STRUCTURAL FLOOR SLAB, | | IF ANY, ARE TO BE TAKEN?DOES THE | | ARCHITECT HAVE KNOWLEDGE OF THE | | EXISTING CONDITIONS?SEE FBC 104.2.3. | | | | SHOW THE FIRE PROTECTION, (SPRINKLERS & | | ALARM) DESIGN ALTERATION ON THE PLANS. | | SEE FBC 104.3.1 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-08-11 |
Time |
08:15 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-08-11 |
Time |
07:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-10-11 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-07 |
Time |
14:32 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2002-10-11 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-08-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-08-22 |
Time |
07:33 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2002-08-22 |
Time |
07:33 |
Sent To |
|
|
Notes |
2002-08-22 00:00:00 | ************* UNSAT ****************** | | | | 1) NOTE: SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | PER NFPA-72 2-2.1.1.1. | | IN THE VICINITY OF BEDROOMS AND CLOSE | | PROXIMITY OF STIRWAYS. 2-5.2.1.3 | | 3'FT FROM BATHS/KITCHENS.2-5.2.1.6 | | | | 2) NOTE: PLEASE LIST THE REQ`D BATH(S) | | CIRCUIT(S). PER 210-11-C-3 | | MUST BE 20A AND #12AWG. | | PLEASE NOTE MISSING REQ`D RECEPTS IN | | MANY BATHS REQ`D PER 210-52D | | | | 3) NOTE: PLEASE SHOW ALL OUTLETS SERVING | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | -ED PER 210-8-A-6. | | INCLUDES KITCHEN ISLANDS. | | | | 4)NOTE: PLEASE NOTE OUTLET SPACING FOR | | KITCHEN OUTLETS TO MEET 210-52-C,1,2,3, | | ,4,5. | | | | 5)NOTE: PLEASE NOTE MISSING EGRESS | | LIGHTING PER 210-70, HALLWAY ETC. | | | | 6) NOTE: PLEASE SHOW ALL OUTLET SPACING | | TO MEET 2`,6`,12` RULE PER 210-52. | | | | 7))NOTE: PLEASE LIST THE REQ`D ARC | | FAULT PROTECTED CIRCUITS ON PANEL | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | CIRCUIT PROTECTION. PER 210-12 | | | | 8)NOTE: PLEASE SHOW LOCATION OF EXISTING | | PANELS. | | PLEASE SUBMIT PANEL SCHEDULES. | | | | PLEASE NOTE THAT NO HANDWRITTEN CHANGES | | MAY BE ON PLANS, UNLESS EACH CHANGE IS | | SIGNED AND DATED BY THE ARCH OF RECORD. | | FS/FAC 481.221. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-10-18 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2002-10-18 |
Time |
11:09 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-10-18 00:00:00 | REVIEW PASSED BUILDING COMMENTS LM |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-08-28 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-08-28 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-08-28 |
Time |
11:14 |
Sent To |
|
|
Notes |
2002-08-28 00:00:00 | SEE BUILDING PLAN REVIEW COMMENTS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-07 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-07 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-07 |
Time |
14:31 |
Sent To |
E |
|
Notes |
2003-08-07 00:00:00 | TO BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-01-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-27 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-23 |
Time |
13:04 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-01-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-28 |
Time |
09:43 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2003-01-28 |
Time |
09:43 |
Sent To |
B |
|
Notes |
2003-01-28 00:00:00 | REVISION MECHANICAL PERMIT 02081084 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-10-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-27 |
Time |
13:04 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2002-10-16 |
Time |
10:00 |
Sent To |
|
|
Notes |
2002-10-16 00:00:00 | PROVISO:MECHANICAL PERMIT 02081084 | | | | BALANCED RETURN AIR - 2001 FBC(M) 601.4 | | RETURN AIR SHALL BE EQUAL TO SUPPLY | | AIR BY MEANS OF AIR TRANSFER OR A | | RETURNAIR (JUMPER). | | | | SPOKE WITH BRET FROM MARION CONSTRUCTION | | 10-16-02 - DISCREPANCY ON PLAN SHEET #6 | | TWO SEPARATE NOTES ONE INDICATES THE | | EXISTING UNITS ARE BEING REPLACED. | | SUBMITTAL LETTER TO FOLLOW FROM | | ARCHITECT INDICATING "CHANGE-OUT" | | SIZING OF OLD EQUIPMENT AS WELL AS NEW. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-09-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-09-07 |
Time |
08:28 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2002-09-07 |
Time |
08:27 |
Sent To |
|
|
Notes |
2002-09-07 00:00:00 | PLAN DENIED | | NO PLANS,ENERGY CALCULATIONS,MANUAL (J) | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-10-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-10-12 |
Time |
16:16 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2002-10-12 |
Time |
16:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-08-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-08-30 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-08-30 |
Time |
16:36 |
Sent To |
|
|
Notes |
2002-08-30 00:00:00 | PASSED/PROVISO - ALL CAPPED SANT.- VENT- | | WATER LINES SHALL BE INSPECTED PRIOR TO | | COVERING. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2002-10-18 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2002-10-18 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|