Plan Review Details - Permit 02080924
Plan Review Stops For Permit 02080924
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-10-30 Cont ID  
Sent By csiegber Date 2004-02-06 Time 14:49 Rev Time 1.25
Received By jwitmer Date 2002-10-30 Time 12:25 Sent To  
Notes
2002-10-30 00:00:00 
  
  
 *** ISSUED MASTER***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02080924
 ADDRESS: LIBERTY BAY
 MASTER "D"
 CONT: HOME DYNAMICS
 MIKE HANLEY
 TELL # (954)520-1698
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 BUILDING PLAN REIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-07 Cont ID  
Sent By btrobaug Date 2002-10-29 Time 09:15 Rev Time 1.00
Received By jwitmer Date 2002-09-07 Time 15:19 Sent To  
Notes
2002-09-07 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02080924
 ADD:******LIBERTY BAY*****
 ****MODEL "D"****
 CONT: HOME DYNAMICS CONSTRUCTION
 TEL: (954)275-8569
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) SHEET A-2 NOTE: MONOLITHIC CONCRETE
 FOUNDATION WITHOUT HOOK BARS DESIGNED
 BY RATIONAL ANYLSIS PER ACI 318-89
 THE PLAN DOES NOT INDICATE AS TO THE
 MINIMUM DEPTH REQUIRED? DETAI 3/1 GARAGE
 SLAB, DOES THE VERTICAL DOWELS REQUIRE
 ADDTIONAL LENGHT INTO THE CONCRETE TO
 GET THE REQUIRED COVERAGE SINCE THERE
 IS NO HOOK?
 ACI 530 8.5.2 EMBEDDMENT LENGHT MIN 12".
  
 2105.1 SHEAR WALLS. WHERE THE STRUCTURE
 DEPENDS ON MASONARY WALLS FOR LATERAL
 STABILITY, SHEAR WALLS SHEAR WALLS SHALL
 BE PROVIDED TO THE DIRECTION OF THE
 LATERAL FORCES RESISTED. DEMONSTRATE HOW
 THE 2ND STORY FRAME WALLS WILL TRANSFER
 THE WIND LOADS IF WIND IS AT 90 DEGREES
 TO THE FRONT OR REAR OF BUILDING. THE
 FRONT OF THE BUILDING IS BEING HELD
 UP BY COLUMNS NO WALL SECTIONS TO TRANS-
 FER SHEAR.
  
 3) NO FLOOR DIAPHRAM INDICATED, 2310.3.1
 NOR IS THERE IN THE 2ND STORY FRAME
 WALLS, TABLE 2310.2B PROVIDE ADDITIONAL
 INFORMATION.
  
 4) SHEET A-1 INDICATES WIND ZONE OF
 130 MPH, CORRECT TO 140 MPH.
  
 5) SHEET A-4 MEAN ROOF HEIGHT < 25'.
 ROOF SHEATHING NAILING REQUIREMENTS
 ZONE 1 & 2 8D COMMONS
 6" EDGES & 6" INTERMEDIATES
 ZONE 38D COMMONS
 4" EDGES & 6" INTERMEDIATES
  
 6) PROVIDE KEY PLAN FOR INSTALLTION
 SCHEDULE/ STORM SHUTTERS.
  
 7) 1007.8.1 WINDERS SHALL HAVE A
 MINIMUM TREAD DEPTH OF 6" AT THE NARROW-
 EST EDGE & SHALL HAVE A MINIMUM TREAD
 DEPTH OF 11" AT A POINT 12" FROM THE
 NARROW EDGE. WINDERS SHALL BE PERMITTED
 TO BE USED AS A COMPONENT IN MEANS OF
 EGRESS WITHIN A DWELLING UNIT. SEE
 DETAIL A-5.
 JIM WITMER
 PLAN REVIEW
 TEL(561)659-8096 X 8412
 FAX(561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2004-02-12 Cont ID  
Sent By btrobaug Date 2004-02-12 Time 10:09 Rev Time 0.25
Received By btrobaug Date 2004-02-12 Time 10:09 Sent To  
Notes
2004-02-12 00:00:00PLEASE NOTE:
 A MASTER THAT HAS HAD PRIMARY PERMITS
 ISSUED UNDER THAT MASTER, CANNOT BE
 REVISED WITHOUT REVISING ALL PREVIOUSLY
 ISSUED PRIMARY PERMITS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-10-29 Cont ID  
Sent By btrobaug Date 2002-10-29 Time 09:15 Rev Time 0.50
Received By btrobaug Date 2002-10-29 Time 06:50 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-29 Cont ID  
Sent By dpalmer Date 2002-08-29 Time 16:27 Rev Time 0.50
Received By dpalmer Date 2002-08-29 Time 16:27 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-06 Cont ID  
Sent By csiegber Date 2004-02-06 Time 14:49 Rev Time 0.00
Received By csiegber Date 2004-02-06 Time 14:49 Sent To B
Notes
2004-02-06 00:00:00TO JW DESK/MASTERED/E REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-27 Cont ID  
Sent By csiegber Date 2003-10-27 Time 15:24 Rev Time 0.00
Received By csiegber Date 2003-10-27 Time 15:24 Sent To B
Notes
2003-10-27 00:00:00TO JW DESK/REV/MASTERED

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-23 Cont ID  
Sent By alange Date 2003-07-23 Time 14:59 Rev Time 0.00
Received By alange Date 2003-07-23 Time 14:59 Sent To M
Notes
2003-07-23 00:00:00TO PKRAUSS DESK

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-11-07 Cont ID  
Sent By pkrauss Date 2003-11-07 Time 11:19 Rev Time 0.30
Received By pkrauss Date 2003-11-07 Time 11:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-10-24 Cont ID  
Sent By alange Date 2003-07-23 Time 14:59 Rev Time 0.50
Received By hmoser Date 2002-10-24 Time 12:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-08-24 Cont ID  
Sent By hmoser Date 2002-08-24 Time 10:26 Rev Time 0.50
Received By hmoser Date 2002-08-24 Time 10:26 Sent To  
Notes
2002-08-24 00:00:00PLAN DENIED
 1) NEED EXHAUST FAN IN MASTER BATH
 2) NEED DUCT SIZE FOR BEDROOM #3
 RETURN AIR
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-10-26 Cont ID  
Sent By jleech Date 2002-10-26 Time 07:09 Rev Time 0.25
Received By jleech Date 2002-10-26 Time 07:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-08-20 Cont ID  
Sent By jleech Date 2002-08-20 Time 17:44 Rev Time 0.50
Received By jleech Date 2002-08-20 Time 17:44 Sent To  
Notes
2002-08-20 00:00:00MASTER MODEL "D-R" RISER DIAGRAM DOES
 NOT MATCH FLOOR PLAN. FLOOR PLAN SHOWS
 W/M ON FIRST FLOOR, RISER DIAGRAM
 SHOWS W/M ON SECOND FLOOR.

Review Stop Z ZONING
Rev No 1 Status N Date 2002-10-30 Cont ID  
Sent By jwitmer Date 2002-10-30 Time 12:24 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***