2002-09-19 00:00:00 | CHECKLIST: |
| 1-PROVIDE ENGINEERING ANALYSIS/CALCS AND |
| COMPLETE SECTIONS/DETAILS/SPECS FOR |
| DESIGN OF GABLE END AT FRONT ELEVATION |
| CONSIDERING THAT CENTER OF GABLE IS |
| MASONRY AND THE TWO SIDES ARE WOOD |
| TRUSSES. CLARIFY HOW IS THE WALL PUT |
| TOGETHER TO TRANSFER ALL LOADS. SEE |
| SECTIONS 1604.2.4, 2105, 2107, 2117 |
| AND 2313 FBC 2001. |
| 2-NEED RECORDED N.O.C. |
| 3-REVISE ATTIC ACCESS SIZE. NEED 36" MIN |
| NOT 30". SEC. 2309.6 FBC 2001. |
| 4-34SH WINDOW DOESN'T PROVIDE 24" MIN. |
| CLEAR HEIGHT OPENING. SEC. 1005.4.4. |
| 5-PROVIDE COMPLETE/CORRECT INFORMATION |
| FOR STORM SHUTTERS.***NOTE SEE |
| PRODUCT APPROVAL FOR LIMITATIONS. |
| 6-PROVIDE PRODUCT APPROVAL FOR: |
| A)SINGLE ENTRY DOOR WITH SINGLE SIDELITE |
| ONLY AS SHOWN ON PLANS. |
| B)SINGLE HUNG WINDOWS. |
| C)FIXED WINDOWS. |
| D)WINDOW MULLIONS. |
| E)SLIDING GLASS DOORS. |
| F)GARAGE DOORS WITH LEGIBLE DRAWINGS. |
| |
| 7-PROVIDE UL LISTING AND COMPLETE SPECS |
| FOR ONE HOUR FIRE RATED GLASS BLOCK |
| ASSEMBLY REQUIRED BY TABLE 600 FBC. |
| **NOTE: NEED SAFETY GLASS IF GLASS BLOCK |
| UNIFORM FACE THICKNESS IS LESS THAN |
| 0.25". SEC. 2405.2.2 FBC 2001. |
| 8-REVISE GLASS BLOCK ASSEMBLY DETAIL TO |
| MATCH UL SPECIFICATIONS.SEE SUB- |
| MITTAL PRESENTED BY CONTRACTOR. |
| **NOTE: WINDOW SCHEDULE TO SPECIFY ONE |
| HOUR FIRE RATED GLASS BLOCK ASSEMBLY. |
| 9-SPECIFY SPACING FOR WWM SUPPORTS IN |
| CONCRETE SLAB. SEC. 1909.3 FBC 2001. |
| 10-PROVIDE COMPLETE STRUCTURAL DETAIL |
| FOR RECESSED WINDOWS TO ALLOW FOR |
| STORM SHUTTERS INSTALLATION. ***NOTE: |
| SEE PRODUCT APPROVAL FOR LIMITATIONS |
| AND REQUIRED ADDITIONAL ENGINEERING. |
| 11-ENERGY CALCULATIONS: |
| A)REVISE UNDER ATTIC AREA. SEE SECTION |
| 602.1.ABC.1.2 CHAPTER 13 FBC 2001. |
| B)OWNER/AGENT TO DATE BOTTOM OF FORM TOO |
| 12-WALL SECTIONS NOTE #14 AND VENT CALCS |
| DON'T MATCH. REVISE AS REQUIRED. |
| 13-SHEET S-2:A) UPDATE NOTE #2: SEMCO |
| IS NOT LONGER IN BUSINESS. |
| B)UPDATE NOTE #3 TO REFLECT FBC 2001. |
| C)CLARIFY WHY BLOCKING AT FRONT GABLE |
| END IS SHOWN PARTIALLY AND NOT ALL THE |
| WAY DOWN TO THE ENDS. SEC. 104.2.1.2 |
| CITY AMENDMENTS TO FBC 2001. |
| 14-SHEET S-1:A)CLARIFY DIMENSION OF |
| 4'-1 1/2" SHOWN ON SECTION 5. |
| B)PROVIDE INSTALLATION DETAIL FOR LINTEL |
| L-7 AT FRONT PORCH SHOWING CONTINUOUS |
| VERTICAL REINFORCEMENT. SEC. 104.2.1.2 |
| CITY AMENDMENTS TO FBC 2001. |
| C)REVISE LINTEL SCHEDULE TO MATCH PLANS. |
| CHECK SIZES SPECIFIED. |
| 15-IDENTIFY ROOF ZONES ON ROOF FRAMING |
| PLAN. TABLE 2306.1 CITY AMENDMENTS. |
| 16-REVISE TRUSS ANCHOR SCHEDULE TO MATCH |
| USP PUBLISHED VALUES. PROVIDE ENGINEE- |
| RING CALCS FOR DIFFERENT VALUES. SEC. |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| 17-SEE GARAGE DOOR PRODUCT APPROVAL FOR |
| STRUCTURAL BUCK REQUIREMENTS. REVISE |
| DETAIL AS REQUIRED. |
| **SPECIFY SIZE OF WASHER. |
| 18-UPDATE FOUNDATION NOTE ON SHEET C-1: |
| NEED 0.006 MIL VISQUEEN MIN. SECTION |
| 1909.2 FBC 2001. |
| 19-REVIEW ALL FLOOR PLANS AND MAKE SURE |
| KEYED DETAILS/SECTIONS MATCH THOSE |
| SHOWN ON THE OTHER SHEETS. |
| 20-UPDATE GENERAL NOTE ON SHEET A-1: |
| REFER TO FPC 2001, NOT SPC 1994. |
| 21-SHEET A-3: REVISE SECTION THRU ENTRY |
| PORCH TO MATCH MASONRY GABLE END SPECS |
| SEE SECTION 2117 FBC 2001. |
| 22-SURVEY AND FLOOR PLANS DON'T MATCH. |
| ZERO LOT WALL IS ON THE OPPOSITE SIDE. |
| CLARIFY WHY. |
| 23-PROVIDE SOIL TEST REPORT. |