Plan Review Details - Permit 02080797
Plan Review Stops For Permit 02080797 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-04-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-04-11 |
Time |
14:44 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-04-11 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-08-27 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-11 |
Time |
08:30 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2002-08-27 |
Time |
12:30 |
Sent To |
M |
|
Notes |
2002-08-27 00:00:00 | ************* PROVISO/NOTES ********** | | | | 1)NOTE: PLEASE NOTE EQUIPMENT GROUNDING | | CONDUCTOR BETWEEN MAIN AND PANEL NOT | | SHOWN. SIZE PER 250-122 | | | | 2)NOTE: PLEASE NOTE WRONG ARTS FROM NEC | | ARE REFERENCED IN NOTES. THOSE ARTS ARE | | FROM THE 96 NEC. PLEASE CORRECT TO 99 | | NEC. | | | | 3)NOTE: PLEASE NOTE, NO INDICATION FOR | | REQ`D ARC FAULT PROTECTION PER 210-12. | | IT IS NOTED THAT RECEPTS ARE SHOWN W/ | | A SLASH BUT NO INDICATION IS SHOWN ON | | SCHEDULE. | | | | 4)NOTE: PLEASE NOTE AIC RATING SHOWN AS | | A MISPRINT AS 22.00, SHOULD BE 22,000. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW BEFORE ROUGH ELECTRICAL INSPECT- | | -IONIS CALLED IN. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-04-11 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-04-11 |
Time |
08:29 |
Sent To |
E |
|
Notes |
2003-04-11 00:00:00 | DP DESK |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-08-27 |
Time |
12:30 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2002-08-28 |
Time |
10:30 |
Sent To |
R |
|
Notes |
2002-08-28 00:00:00 | MECHANICAL PERMIT 02080853 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-08-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-08-26 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-08-26 |
Time |
18:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2002-08-30 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-08-28 |
Time |
10:31 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2002-08-29 |
Time |
08:52 |
Sent To |
|
|
Notes |
2002-08-30 00:00:00 | REVIEW & STAMPED PLANS 08/29/2002 | | CALC. FEES & PRINT CARD 08/30/2002 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-08-13 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-08-13 |
Time |
15:21 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy