Plan Review Details - Permit 02080638
Plan Review Stops For Permit 02080638
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-12-10 Cont ID  
Sent By hpiskura Date 2002-12-10 Time 14:11 Rev Time 0.00
Received By hpiskura Date 2002-11-22 Time 10:53 Sent To FIRE
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-08-30 Cont ID  
Sent By pkrauss Date 2002-11-21 Time 09:07 Rev Time 0.00
Received By hpiskura Date 2002-08-30 Time 13:09 Sent To  
Notes
2002-08-30 00:00:00THE LAND DESIGN SOUTH PLANS ARE REQUIRED
 TO BE SIGNED SEALED AND DATED.SEE
 FBC 104.2.2.
  
 SHOW THE ATTIC ACCESS REQUIRED BY FBC
 2309.6
  
 SHOW THE ATTIC VENTILATION REQUIRED BY
 FBC 2309.7 INCLUDE THE FREE AREA OF ANY
 SCREENED VENT TO BE USED.
  
 SHEET 3 OF 3 "DESIGN CHART" DECLARES
 ROOF ONLY, WHAT WAS USED FOR THE REST
 OF THE BUILDING?INCLUDE COMPONENTS
 AND CLADDING FOR THE WALLS.
  
 SEE FBC 104.2.1.1 FOR THE ROOF COVERING
 DESIGN INFORMATION TO BE PLACED ON THE
 PLANS.
  
 HOW WAS THE 0.18 +/- INTERNAL PRESSURE
 COEFFICIENT DETERMINED?SEE FBC
 1606.1.4.2 FOR ENCLOSED BUILDING
 CRITERIA.
  
 SHEET 3 OF3 CALLS OUT A "USP DTC"
 CONNECTOR FOR THE TRUSSES.USP DOES
 NOT LIST A "DTC" CONNECTOR IN THEIR
 CATALOG.WHAT IS INTENDED TO BE USED?
  
 WHAT GROUT SPECIFICATION AND VARIOUS
 OTHER SIGNIFICANT DESIGN CRITERIA ARE
 TO BE USED FOR THE FILLED CELL MASONRY?
 SEE FBC 2103.1.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-28 Cont ID  
Sent By dpalmer Date 2002-08-28 Time 20:18 Rev Time 0.30
Received By dpalmer Date 2002-08-28 Time 20:15 Sent To  
Notes
2002-08-28 00:00:00************ NOTE *************
  
 PLEASE NOTE , PLANS REDLINED AND NOTED
 THE NO MORETHAN 8' OF UNPROTECTED
 CONDUCTORS INSIDE BLDG PER 230-70A OF
 LOCAL AMENDMENTS.
  
 PLEASE NOTE ROOM FOR ELECTRICAL PANEL
 MUST MEET 110-26/ 384-7. SHOWN AS
 STORAGE AND EQUIPMENT ROOM.?
  
 NOTED ON PLANS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-12-10 Cont ID  
Sent By hpiskura Date 2002-12-10 Time 14:11 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-12-11 Cont ID  
Sent By nmccray Date 2002-12-11 Time 16:08 Rev Time 0.00
Received By nmccray Date 2002-12-11 Time 16:08 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-08-22 Cont ID  
Sent By hpiskura Date 2002-12-10 Time 14:14 Rev Time 0.00
Received By mcarsill Date 2002-08-22 Time 12:04 Sent To  
Notes
2002-08-22 00:00:001) ADDRESS REQUIRED TO BE INSTALLED ON
 BUILDING. SIX INCH NUMERALS REQUIRED.
  
 2) THE FLOOR PLAN AND ELECTRICAL PLAN
 INDICATES TWO DIFFERENT ROOM NAMES FOR
 THE STORAGE AND EQUIPMENT ROOM. PLEASE
 REVISE.
  
 3) SINCE NO FIRE SPRINKLER PROTECTION
 IS TO BE PROVIDED, THE STORAGE OR
 EQUIPMENT ROOM IS TO BE AT LEAST ONE
 HOUR FIRE RATED WITH THE PROPER
 OPENING PROTECTIVES.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-08 Cont ID  
Sent By btrobaug Date 2002-11-08 Time 17:04 Rev Time 0.00
Received By btrobaug Date 2002-11-08 Time 17:04 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-11-21 Cont ID  
Sent By pkrauss Date 2002-11-21 Time 09:04 Rev Time 0.30
Received By pkrauss Date 2002-11-21 Time 09:04 Sent To B
Notes
2002-11-21 00:00:00REVIEW FORBATHROOMS AT THE POOL HOUSE
  
 BATHROOMS ARE MECHANICALLY EXHAUSTED &
 WINDOWS ARE LOUVERED FOR FRESH AIR.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-09-07 Cont ID  
Sent By kstevens Date 2002-11-12 Time 17:16 Rev Time 0.50
Received By hmoser Date 2002-09-07 Time 08:02 Sent To  
Notes
2002-09-07 00:00:00PLAN DENIDE
 NO PLANS,ENERGY CALCULATIONS,OR MANUAL
 (J)
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-12-14 Cont ID  
Sent By kstevens Date 2002-12-14 Time 20:20 Rev Time 1.00
Received By kstevens Date 2002-12-14 Time 20:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-11-12 Cont ID  
Sent By kstevens Date 2002-11-12 Time 17:09 Rev Time 0.50
Received By kstevens Date 2002-11-12 Time 17:09 Sent To  
Notes
2002-11-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) FROM PREVIOUS REVIEW: SHEET #3,
 SANITARY RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN. THE DRINKING FOUNTAIN
 IS NOT SHOWN. DRINKING FOUNTAINS SHALL
 NOT DRAIN THROUGH THE THE WET VENT OF
 THE BATHROOM GROUPS 909.1/909.1.2.
 DRINKING FOUNTAINS SHALL DRAIN DOWN-
 STREAM OF THE BATHROOM GROUP.
 2) NEW COMMENT: PLEASE PROVIDE A WATER
 RISER DIAGRAM. WATER HAMMER ARRESTORS
 PER 604.9 AND LOCATED NEAR THE FIXTURES
 WHERE REQUIRED NOT AT TOP OF DROP IN THE
 CEILING. BACKFLOW REQUIRED ON WATER
 SERVICE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-08-31 Cont ID  
Sent By btrobaug Date 2002-11-08 Time 17:04 Rev Time 0.00
Received By kstevens Date 2002-08-31 Time 11:53 Sent To M
Notes
2002-08-31 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) PLEASE ROUTE PLANS TO PALM BEACH
 COUNTY HEALTH UNIT 901 EVERNIA ST
 (561) 355-3018 X 1194 PRIOR TO RESUB-
 MITING.
 2) SHT 3 SANITARY RISER DIAGRAM DOES NOT
 REFLECT FLOOR PLAN. DRINKING FOUNTAIN
 IS NOT SHOWN ON RISER DIAGRAM. DRINKING
 FOUNTAINS SHALL TIE IN DOWNSTREAM OF
 THE BATHROOM GROUP WET VENT.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-20 Cont ID  
Sent By sgraham Date 2002-08-20 Time 10:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***