Plan Review Details - Permit 02080492
Plan Review Stops For Permit 02080492
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-21 Cont ID  
Sent By btrobaug Date 2002-08-21 Time 13:26 Rev Time 0.00
Received By btrobaug Date 2002-08-21 Time 13:10 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-01 Cont ID  
Sent By dpalmer Date 2002-11-01 Time 13:53 Rev Time 0.00
Received By dpalmer Date 2002-11-01 Time 13:53 Sent To R
Notes
2002-11-01 00:00:00TO JULIO./WRT

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-03-11 Cont ID  
Sent By rregueir Date 2003-03-11 Time 17:27 Rev Time 0.33
Received By rregueir Date 2003-03-11 Time 17:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-02-11 Cont ID  
Sent By rregueir Date 2003-02-11 Time 17:49 Rev Time 0.25
Received By rregueir Date 2003-02-11 Time 17:49 Sent To  
Notes
2003-02-11 00:00:00MECH PLAN REVIEW FAILED: ENERGY CALCS
 WERE NOT IN MASTER SET OF PLANS AND NOT
 PROVIDED WITH REVISED MECH DRAWINGS.
 REFER TO BUILDING PLAN REVIEW PROVISO.
 RON REGUEIRO 561-659-8096 X8512

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-20 Cont ID  
Sent By hmoser Date 2002-08-20 Time 17:16 Rev Time 0.50
Received By hmoser Date 2002-08-20 Time 17:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-17 Cont ID  
Sent By jleech Date 2002-08-17 Time 12:20 Rev Time 0.33
Received By jleech Date 2002-08-17 Time 12:20 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-11-06 Cont ID  
Sent By jgomez Date 2002-11-06 Time 09:41 Rev Time 2.00
Received By jgomez Date 2002-11-06 Time 09:41 Sent To  
Notes
2002-11-06 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-STORM SHUTTERS: A)DESIGN PRESSURES
 SPECIFIED HAVE LIMITATIONS FOR PANEL
 SPAN. SEE PLANS FOR CALCULATED DESIGN
 PRESSURES AND REVISE AS REQUIRED.
 B)CLARIFY TYPE OF ANCHOR USED. RAWL OR
 CAULK-IN.
 C)MARK ON DWGS THE SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE & SPACING
 TO BE USED.
 2-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SINGLE SIDELITE ASSEMBLY AS
 SHOWN ON PLANS.
 3-PROVIDE COMPLETE UL LISTING AND SPECS
 FOR ONE HOUR FIRE RATED GLASS BLOCK
 ASSEMBLY AS REQUIRED BY TABLE 600 FBC.
 **ALSO, PROVIDE CLEAR & LEGIBLE PRODUCT
 APPROVAL FOR GLASS BLOCK.
 **NOTE: IF GLASS BLOCK FACE THICKNESS IS
 LESS THAN 0.25", THEN SAFETY GLASS IS
 REQUIRED. SEC. 2405.2.2. FBC 2001.
 4-ENERGY CALCULATIONS WERE NOT REVISED.
 REVISE UNDER ATTIC AREA AS REQUIRED BY
 SEC. 602.1.ABC.1.2 OF CHAPTER 13 FBC.
 OWNER/AGENT TO SIGN AND DATE FORM ALSO
 5-FOUNDATION PLAN AND FOOTING SCHEDULE
 DON'T MATCH. REVISE AS REQUIRED.
 **ALSO, FOOTING SCHEDULE & WALL SECTIONS
 DON'T MATCH. SEE DIMENSIONS FOR LENGTH
 AND WIDTH AND REVISE AS REQUIRED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-09-18 Cont ID  
Sent By dpalmer Date 2002-11-01 Time 13:53 Rev Time 3.00
Received By jgomez Date 2002-09-18 Time 16:34 Sent To  
Notes
2002-09-18 00:00:00CHECKLIST:
 1-PROVIDE ENGINEERING ANALYSIS/CALCS AND
 COMPLETE SECTIONS/DETAILS/SPECS FOR
 DESIGN OF GABLE END AT FRONT ELEVATION
 CONSIDERING THAT CENTER OF GABLE END @
 FRONT ELEVATION IS MASONRY AND THE TWO
 SIDES ARE PARTIAL GABLE END TRUSSES.
 CLARIFY HOW IS GABLE END WALL PUT
 TOGETHER TO TRANSFER THE LOADS. SEE
 SECTIONS 1604.2.4, 2105, 2107, 2117 &
 2313 FBC 2001.
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-REVISE ATTIC ACCESS SIZE. 36" MIN. NOT
 30". SEC. 2309.6 FBC 2001.
 4-34SH WINDOW DOESN'T PROVIDE 24" MIN.
 CLEAR OPENING HEIGHT. SEC. 1005.4.4.
 5-PROVIDE COMPLETE/CORRECT INFORMATION
 FOR STORM SHUTTERS. SEE PRODUCT APPRO-
 VAL FOR LIMITATIONS.
 6-PROVIDE PRODUCT APPROVAL FOR SINGLE
 ENTRY DOOR WITH SINGLE SIDELITE AS
 SHOWN ON PLANS.
 7-PROVIDE UL LISTING AND COMPLETE SPECS
 FOR ONE HR FIRE RATED GLASS BLOCK
 ASSEMBLY REQUIRED BY TABLE 600 FBC.
 **NOTE: GLASS BLOCK TO BE SAFETY GLASS
 IF UNIFORM FACE THICKNESS IS LESS THAN
 0.25". SEC. 2405.2.2 FBC 2001.
 8-REVISE GLASS BLOCK ASSEMBLY DETAIL TO
 MATCH UL SPECIFICATIONS SUBMITTED.
 **REVISE WINDOW SCHEDULE: SPECIFY REQ'D
 1 HR FIRE RATED GLASS BLOCK.
  
 9-SPECIFY SPACING FOR SUPPORTS OF WWM
 IN CONCRETE SLAB. SEC. 1909.3 FBC 2001
 10-PROVIDE COMPLETE DETAIL AT RECESSED
 WINDOWS TO ALLOW FOR STORM SHUTTERS
 INSTALLATION. SEE STORM SHUTTERS
 PRODUCT APPROVAL FOR LIMITATIONS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 11-ENERGY CALCULATIONS:
 A)REVISE UNDER ATTIC AREA. SEE SECTION
 602.1.ABC.1.2 CHAPTER 13 FBC 2001.
 B)OWNER/AGENT TO DATE BOTTOM OF FORM
 WHEN SIGNING IT.
 12-WALL SECTIONS NOTE #14 AND VENT CALCS
 DON'T MATCH. REVISE AS REQUIRED.
 13-SHEET S-2:A) UPDATE NOTE #2: SEMCO
 CONNECTOR.
 B)UPDATE NOTE #3: REFER TO FBC 2001 FOR
 140 MPH, NOT ASCE 7-93.
 C)CLARIFY WHY BLOCKING AT FRONT END IS
 SHOWN ON PARTIAL GABLE END AND NOT ALL
 THE WAY DOWN TO THE ENDS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 14-SHEET S-1: A) CLARIFY DIMENSION OF
 4'-1 1/2" ON SECTION 5.
 B)PROVIDE INSTALLATION DETAIL FOR LINTEL
 L-7 AT FRONT PORCH. LINTEL IS NOT
 RESTING ON MASONRY COLUMN FOR CONTI-
 NUOUS VERTICAL REINFORCEMENT. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 C)REVISE LINTEL SCHEDULE TO MATCH PLANS.
 CHECK SIZES AND LINTEL SPECIFIED.
  
 15-IDENTIFY ROOF ZONES ON ROOF FRAMING
 PLAN. TABLE 2306.1 CITY AMENDMENTS.
 16-REVISE TRUSS ANCHOR SCHEDULE TO MATCH
 USP PUBLISHED VALUES. PROVIDE ENGI-
 NEERING CALCS FOR DIFFERENT VALUES.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 17-SEE PRODUCT APPROVAL FOR GARAGE DOORS
 STRUCTURAL BUCK REQUIREMENTS. REVISE
 DETAIL AS REQUIRED.
 **SPECIFY WASHER.
 18-UPDATE FOUNDATION NOTE ON SHEET C-1:
 NEED 0.006 MIL VISQUEEN MIN. SECTION
 1909.2 FBC 2001.
 19-REVIEW ALL FLOOR PLANS AND CLEARLY
 KEY DETAILS AND SECTIONS THAT MATCH
 SHEET THEY ARE REFERENCING TO.
 20-UPDATE GENERAL NOTE ON SHEET A-1:
 REFER TO FPC 2001, NOT SPC 1994.
 21-SHEET A-3: REVISE SECTION THRU ENTRY
 TO MATCH MASONRY CONSTRUCTION.
 SEC. 2117 FBC 2001.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-07 Cont ID  
Sent By sgraham Date 2002-08-07 Time 08:04 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***