Plan Review Details - Permit 02080364
Plan Review Stops For Permit 02080364
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-19 Cont ID  
Sent By dpalmer Date 2002-08-19 Time 10:51 Rev Time 0.00
Received By dpalmer Date 2002-08-19 Time 10:51 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-31 Cont ID  
Sent By dpalmer Date 2002-10-31 Time 13:08 Rev Time 0.00
Received By dpalmer Date 2002-10-31 Time 13:08 Sent To B
Notes
2002-10-31 00:00:00TO JULIO

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-10 Cont ID  
Sent By rregueir Date 2003-03-10 Time 18:30 Rev Time 0.33
Received By rregueir Date 2003-03-10 Time 18:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-15 Cont ID  
Sent By hmoser Date 2002-08-15 Time 18:42 Rev Time 0.50
Received By hmoser Date 2002-08-15 Time 18:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-06 Cont ID  
Sent By jleech Date 2002-08-06 Time 19:42 Rev Time 0.33
Received By jleech Date 2002-08-06 Time 19:41 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-11-06 Cont ID  
Sent By jgomez Date 2002-11-06 Time 18:13 Rev Time 2.50
Received By jgomez Date 2002-11-06 Time 18:13 Sent To  
Notes
2002-11-06 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-SEE ENGINEERING ANALYSIS AND REVISE
 THE DIAPHRAGM SCHEDULE AS REQUIRED.
 **ALSO, REVISE THE SPECS ON THE WALL
 SECTIONS/DETAILS TO MATCH ENGINEERING
 ANALYSIS.
 2-STORM SHUTTERS: A)DESIGN PRESSURES
 SPECIFIED HAVE LIMITATIONS ON PANEL
 SPAN. SEE DESIGN PRESSURES CALCULATED
 BY ARCHITECT AND REVISE AS REQUIRED.
 B)MARK ON DRAWINGS SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE AND SPACING
 TO BE USED.
 3-REVISE DETAIL 11/S3. NEED ONE HR FIRE
 RATED ASSEMBLY CONSIDERING EXPOSURE TO
 FIRE ON THE EXTERIOR AND INTERIOR SIDE
 AS REQ'D BY TABLE 600 FOOTNOTE I.
 4-NO INFORMATION WAS GIVEN ON THE SIZE
 OF ANCHOR BOLTS TO BE USED AT BOTTOM
 PLATE OF STEEL COLUMN. DETAIL 41/S2
 REFERS TO COLUMN SCHEDULE, BUT THERE
 IS NO INFORMATION GIVEN ON THE COLUMN
 SCHEDULE. PROVIDE INFORMATION AS REQ'D

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-09-10 Cont ID  
Sent By jgomez Date 2002-09-10 Time 18:36 Rev Time 3.50
Received By jgomez Date 2002-09-10 Time 18:36 Sent To  
Notes
2002-09-10 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-PROVIDE ENGINEERING ANALYSIS/CALCS FOR
 CLARIFICATION OF HOW THE MAIN WIND
 FORCE RESISTING SYSTEM (MWFRS) WAS
 DESIGNED TO RESIST AND TRANSFER ALL
 LOADS TO FLOOR AND CEILING DIAPHRAGMS
 CONSIDERING THE DOUBLE CEILING AREA
 AND THE PARTIAL FLOOR DIAPHRAGM
 SUPPORTED ON WOOD COLUMNS WITH
 CONNECTORS (TOP AND BOTTOM) THAT DON'T
 PROVIDE SUPPORT FOR LATERAL FORCES.
 SEE SEC. 1606.2.4 FBC 2001.
 2-PROVIDE ENGINEERING ANALYSIS/CALCS FOR
 CLARIFICATION OF MASONRY WALLS LATERAL
 STABILITY (SEE SECTION 2105 FBC 2001)
 AND LATERAL SUPPORT (SEE SECTION 2107)
 CONSIDERING THE HIGH VOLUME AREA AND
 SINGLE BOND BEAM ONLY.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 3-A)PROVIDE FIREBLOCKING AT STAIRS.
 INCLUDING AT TOP AREA. SEC. 2305.1.4
 B)SPECIFY FIREBLOCKING AT WALL SECTIONS
 AND PROVIDE GENERAL SPECIFICATIONS FOR
 REQUIRED FIREBLOCKING AT ALL CONCEALED
 SPACES. SEC. 2305.1.4 FBC 2001.
 4-AREA TABULATION ON SHEET C-1 AND A-1
 DON'T MATCH. REVISE AS REQUIRED.
 5-PROVIDE COMPLETE/CORRECT INFORMATION
 FOR STORM SHUTTERS OR APPLY FOR A SEPA
 RATE PERMIT. SEE CITY IMPLEMENTATION
 STANDARD FOR HURRICANE MISSILE IMPACT
 PROTECTION.
 6-PROVIDE DETAIL/SPECIFICATIONS FOR ONE
 HOUR FIRE RATED WALL ASSEMBLY @ FRAMED
 WALL AREA ABOVE BOND BEAM AT ZERO LOT
 LINE AS REQUIRED BY TABLE 600 FBC 2001
 7-PROVIDE COMPLETE DETAILS AND SPECS FOR
 PRECAST LINTELS AT REAR PORCH. SPECIFY
 ATTACHMENT TO COLUMNS AND TO WALL
 SHOWING STEEL REINFORCEMENT THAT WILL
 RESIST UPLIFT LOADS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 8-SOME LINTELS SHOWN ON PLANS DON'T
 MATCH OPENING SIZES SHOWN ON LINTEL
 SCHEDULE. REVISE AS REQUIRED.
 9-SPECIFY SIZE & REINFORCEMENT FOR CON-
 CRETE PAD AT REAR PORCH COLUMN. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 10-PROVIDE LEGIBLE PRODUCT APPROVAL FOR
 ENTRY DOORS AND GARAGE DOORS.
 11-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR
 ARCHED WINDOWS AT FRAMED AREA.
 **NOTE: NEED SPECS FOR ATTACHMENT TO
 MASONRY WALL AS WELL.
 12-NOTE #2 ON SHEET A-1 CALLS FOR WINDOW
 TO BE RECESSED TO ALLOW FOR STORM
 SHUTTER INSTALLATION. PROVIDE COMPLETE
 STRUCTURAL DETAIL/SPECS.
 **NOTE: SEE STORM SHUTTERS INFORMATION
 FOR TRACK AND MOUNTING CONDITIONS TO
 BE USED CONSIDER'G THE "EDGE DISTANCE"
 AND "GLASS SEPARATION".
 13-SEE PRODUCT APPROVAL FOR GARAGE DOOR
 STRUCTURAL BUCK REQUIREMENTS & PROVIDE
 DETAIL AS REQUIRED. SPECIFY ANCHOR
 SIZE, SPACING AND WASHER TO BE USED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 14-SPECIFY FIRECUT REQUIREMENTS ON THE
 STRUCTURAL WALL SECTIONS. SEC. 2305.4
 15-STAIR FLOOR PLAN: CLARIFY NOTE #13.
 THERE IS NOT A POST WHERE THE ARROW IS
 POINTING. SEE PLAN ON SHEET A-5.
 16-IF WOOD COLUMNS ARE CHANGED TO STEEL
 COLUMNS, THEN REMEMBER TO UPDATE STAIR
 FRAMING PLANS AND SECTIONS AS REQUIRED
 17-SPECIFY SPACING FOR WWM IN CONCRETE
 SLAB. SEE SEC. 1909.3 FBC 2001.
 18-SHEET S-1: SOME DETAILS ARE NOT SHOWN
 OR INFORMATION IS OVERLAPPING. REVISE
 AS REQUIRED.
 19-IDENTIFY ROOF ZONES IN ROOF FRAMING
 PLAN FOR NAILING DIAPHRAGM.
 TABLE 2306.1 CITY AMENDMENTS TO FBC.
 20-REVISE TRUSS CONNECTOR TO MATCH USP
 PUBLISHED ENGINEERED VALUES. PROVIDE
 ENGINEERING CALCS FOR DIFFERENT VALUES
 OTHER THAN THOSE PUBLISHED BY USP.
 **NOTE: TAKE INTO CONSIDERATION ACTUAL
 SIZE OF NAILS SPECIFIED. SEE USP CAT.
 21-PROVIDE ATTIC ACCESS ABOVE GARAGE AND
 MORNING ROOM IF CLEAR HEIGHT IS MORE
 THAN 24". SEE. 2309.6 FBC 2001.
 22-24SH AND 34SH WINDOWS DON'T PROVIDE
 THE MIN. CLEAR HEIGHT REQ'D FOR EGRESS
 SEC. 1005.4.4 FBC 2001.
 **NOTE: AFTER REVISING 24SH FOR 24+5SH
 MAKE SURE THAT TOTAL WINDOW OPENING
 IS 5.7S.F. MIN. SEC. 1005.4.4 FBC 2001
 23-UPDATE SHHET C-1. FOUNDATION NOTE
 CALLS FOR 0.004 MIL VISQUEEN. NEED
 0.006 MIL MIN. SEC. 1909.2 FBC 2001.
 24-A)SHT A-1. WHERE IS SEC/5 SHOWN ON
 FLOR PLAN BY GARAGE ENTRY.
 B)MAKE SURE THAT SECTIONS AND DETAILS
 ARE KEYED FOR CORRECT NUMBER AND SHEET
 25-SHEET A-2: UPDATE GENERAL NOTE FOR
 PLUMBING. NEED FBC 2001.
 **ALSO, MAKE SURE THAT ALL DETAILS AND
 SECTIONS ARE CORRECTLY KEYED.
 26-SHEET A3: THERE IS SOME INFORMATION
 ON FRONT ELEVATION THAT IS OVERLAPPING
 27-SHEET A-5: A)STAIR CALCS AREN'T CLEAR
 REVISE/CLARIFY AS REQUIRED.
 B)UPDATE SEMCO STRAP.
 C)HANDRAIL DIMENSION IS OVERLAPPING IN
 STAIR SECTION. CLARIFY/REVISE.
 D)STAIR KEY NOTE #14: DRAFSTOPPING IS NO
 THE SAME AS FIREBLOCKING. NEED FIRE-
 BLOCKING. SEE SEC. 2305.1.4 FBC 2001.
 **ALSO, REVISE LOCATION OF FIREBLOCKING
 AT MIDDLE OF STAIRS. THE WAY IT IS
 SHOWN DOESN'T PROVIDE ANY FIREBLOCKING
 28-SHEET S-1: A)SOME INFORMATION IS OVER
 LAPPING. SEE FOUNDATION PLAN.
 EG: DET. 7/S2 AND SEC/5.
 B)IF USING WOOD COLUMN DETAIL. REMEMBER
 TO UPDATE SEMCO FASTENER.
 C)WHERE IS COLUMN P3 SPECIFIED ON 2ND FL
 FRAMING PLAN.
 D)DRAWING SHALL BE NAMED 2ND FL. FRAMING
 PLAN, NOT GROUND FLOOR FRAMING PLAN.
 29-SHEET S-2: A)UPDATE SECTION 5. REVISE
 SEMCO CONNECTORS.
 B)REVISE SEMCO CONNECTOR SPECIFIED ON
 C)PROVIDE SECTION/DETAIL SHOWING HOW
 IS BEAM 2B-1 ANCHORED TO THE COLUMNS
 AT THE ENDS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 **SAME FOR BEAM AT MORNING ROOM.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-06 Cont ID  
Sent By sgraham Date 2002-08-06 Time 11:50 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***