Plan Review Details - Permit 02080203
Plan Review Stops For Permit 02080203
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-19 Cont ID  
Sent By btrobaug Date 2002-08-19 Time 10:01 Rev Time 0.00
Received By btrobaug Date 2002-08-19 Time 09:53 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-21 Cont ID  
Sent By btrobaug Date 2002-11-21 Time 15:12 Rev Time 0.00
Received By btrobaug Date 2002-11-21 Time 15:12 Sent To R
Notes
2002-11-21 00:00:00TO ROB M./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-17 Cont ID  
Sent By hmoser Date 2002-08-17 Time 10:14 Rev Time 0.33
Received By hmoser Date 2002-08-17 Time 10:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-17 Cont ID  
Sent By jleech Date 2002-08-17 Time 08:52 Rev Time 0.33
Received By jleech Date 2002-08-17 Time 08:52 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-10-03 Cont ID  
Sent By btrobaug Date 2002-11-21 Time 15:12 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-10-03 00:00:00SUBMITTALS FOR CIRCLE TOP FIXED GLASS
 WINDOW AND REVISED TRUSS DRAWING ARE
 NOT ACCEPTABLE.
  
 1) THE PRODUCT APPROVALS THAT WERE
 SUBMITTED ARE FOR CIRCLE TOP FIXED GLASS
 WINDOWS. THE PLAN SHOWS AN ARCHED TOP
 FIXED GLASS WINDOW.
  
 2) THE REVISED TRUSS DRAWINGS ARE NOT
 ACCEPTABLE. THE REVISIONS TO THE TRUSS
 DRAWINGS MUST BE DONE BY THE TRUSS
 ENGINEER, YEKTA KAVASOGLU. PLEASE SUBMIT
 A SIGNED AND SEALED TRUSS DRAWINGS AND
 TRUSS LAYOUT WHICH HAVE BEEN REVIEWED
 AND APPROVED BY THE DESIGNER OF RECORD
 FOR THE STRUCTURE.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-08-27 Cont ID  
Sent By btrobaug Date 2002-08-19 Time 10:01 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-27 00:00:00************BUILDING PROVISO************
  
 1) STRUCTURE IS LOCATED IN AN 'AO' FLOOD
 ZONE AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 2) NO UPLIFT OR CONNECTORS ARE INDICATED
 ON THE ROOF FRAMING PLAN ON SHEET 3A.
 THE ANCHOR SCHEDULE SPECIFIES CONNECTORS
 TO BE USED UNLESS OTHERWISE NOTED ON THE
 FRAMING PLAN. IF THE REACTION VALUES
 GIVEN ON THE TRUSS DRAWINGS EXCEED THE
 CONNECTOR VALUES LISTED IN THE SCHEDULE,
 A REVISED ROOF FRAMING PLAN WILL BE
 REQUIRED.
  
 3)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - ARCHED TOP FIXED GLASS WINDOW AS SHOWN
 ON REAR ELEVATION.
 - STORM PANELS(THE KEY PLAN AND INSTALL-
 ATION SCHEDULE DID NOT HAVE A PRODUCT
 APPROVAL WITH THEM)

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-08 Cont ID  
Sent By sgraham Date 2002-08-08 Time 15:20 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***