Plan Review Details - Permit 02080187
Plan Review Stops For Permit 02080187
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-08-19 Cont ID  
Sent By btrobaug Date 2002-08-19 Time 10:47 Rev Time 0.00
Received By btrobaug Date 2002-08-19 Time 10:28 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-21 Cont ID  
Sent By btrobaug Date 2002-11-21 Time 15:21 Rev Time 0.00
Received By btrobaug Date 2002-11-21 Time 15:21 Sent To R
Notes
2002-11-21 00:00:00TO ROB M./WRT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-08-17 Cont ID  
Sent By hmoser Date 2002-08-17 Time 10:40 Rev Time 0.33
Received By hmoser Date 2002-08-17 Time 10:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-08-17 Cont ID  
Sent By jleech Date 2002-08-17 Time 08:07 Rev Time 0.33
Received By jleech Date 2002-08-17 Time 08:07 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-10-02 Cont ID  
Sent By btrobaug Date 2002-11-21 Time 15:21 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-10-02 00:00:00SUBMITTAL MADE ON 10-1-02 IS DENIED.
  
 1) THE PRODUCT APPROVALS THAT WERE
 SUBMITTED ARE FOR CIRCLE TOP FIXED GLASS
 WINDOWS. THE PLAN SHOWS AN ARCHED TOP
 FIXED GLASS WINDOW.
  
 2) THE REVISED TRUSS DRAWINGS ARE NOT
 ACCEPTABLE. THE REVISIONS TO THE TRUSS
 DRAWINGS MUST BE DONE BY THE ENGINEER
 FOR THE TRUSS COMPANY WHICH IS YEKTA
 KAVASOGLU. PLEASE SUBMIT A SIGNED AND
 SEALED TRUSS LAYOUT THAT HAS BEEN
 REVIEWED AND APPROVED BY THE DESIGNER OF
 RECORD FOR THE STRUCTURE WHICH IS STEVE
 WALSH.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-08-27 Cont ID  
Sent By btrobaug Date 2002-08-19 Time 10:47 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-27 00:00:00************BUILDING PROVISO************
  
 1) STRUCTURE IS LOCATED IN AN 'AO' FLOOD
 ZONE, AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 2)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR ARCHED TOP FIXED GLASS
 WINDOW AS SHOWN ON THE REAR ELEVATION.
  
 3) NO UPLIFT VALUES OR CONNECTORS ARE
 INDICATED ON THE ROOF FRAMING PLAN ON
 SHEET 3. THE NOTE ON THE ANCHOR SCHEDULE
 SPECIFIES THE ANCHORS TO BE USED UNLESS
 OTHERWISE NOTED ON FRAMING PLAN. IF THE
 VALUES GIVEN ON THE TRUSS DRAWINGS
 EXCEED THOSE LISTED IN THE ANCHOR
 SCHEDULE A REVISED FRAMING PLAN WILL BE
 REQUIRED TO BE SUBMITTED FOR REVIEW.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-08-08 Cont ID  
Sent By sgraham Date 2002-08-08 Time 14:17 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***