Plan Review Stops For Permit 02080109 |
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-02-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-02-26 |
Time |
08:35 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-02-26 |
Time |
08:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2002-12-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-26 |
Time |
13:25 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-26 |
Time |
13:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-08-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-08-27 |
Time |
17:54 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2002-08-27 |
Time |
17:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-08-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-08-15 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-08-19 |
Time |
07:10 |
Sent To |
B |
|
Notes |
2002-08-19 00:00:00 | ****************** UNSAT ************* | | | | 1)NOTE: PLEASE NOTE THAT NO MAIN IS | | SHOWN FOR SERVICE. PLEASE NOTE MLO SHOWN | | ON PANEL? 225-31 | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-09 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-09 |
Time |
16:44 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-04 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-11-01 |
Time |
10:28 |
Sent To |
R |
|
Notes |
2002-11-04 00:00:00 | TO LOU HATTEN./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-10-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-10-31 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-10-30 |
Time |
07:22 |
Sent To |
B |
|
Notes |
2002-10-31 00:00:00 | TO LOU HATTEN`S DESK. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-01-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-10 |
Time |
11:02 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-01-10 |
Time |
10:52 |
Sent To |
|
|
Notes |
2003-01-10 00:00:00 | MECH PERMIT 02080172 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-08-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-09 |
Time |
16:44 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2002-08-15 |
Time |
07:52 |
Sent To |
E |
|
Notes |
2002-08-15 00:00:00 | PROVISO:MECHANICAL PERMIT 02080172 | | | | 2001 FBC(M) 402.2 - NATURAL VENTILATION | | FOR OUTSIDE AIR REQUIRMENT. SHOW | | COMPLIANCE FOR THE MINIMUM OPENABLE AREA | | TO THE OUTDOORS. (4 PERCENT OF THE FLOOR | | AREA BEING VENTILATED) OR TABLE 403.3 | | FOR MECHANICAL VENTILATION. | | | | WHERE MULTIPLE AIR-HANDLING SYSTEMS | | SHARE COMMON SUPPLY OR RETURN AIR DUCTS | | OR PLENUMS WITH A COMBINED DESIGN | | CAPACITY GREATER THAN 2,000 CFM, THE | | RETURN AIR & SUPPLY SYSTEM SHALL BE | | PROVIDED WITH SMOKE DETECTORS IN | | ACCORDANCE WITH SECTION 602.1 OR UPON | | ACTIVATION, THE SMOKE DETECTORS SHALL | | SHUT DOWN THE AIR DISTRUBUTION SYSTEM | | 2001 FBC(M) 606.2.2 & 606.4 | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-08-13 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2002-08-13 |
Time |
19:01 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-08-13 |
Time |
19:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2002-08-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-04 |
Time |
10:29 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2002-08-19 |
Time |
18:45 |
Sent To |
|
|
Notes |
2002-08-22 00:00:00 | REVIEW & STAMPED PLANS08/19/2002 | | CALC. FEES & PRINT CARDS08/22/2002 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-08-08 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-08-08 |
Time |
14:07 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|