Plan Review Stops For Permit 02071609 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2003-03-18 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2003-03-18 |
Time |
16:11 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2003-01-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-01-16 |
Time |
08:58 |
Rev Time |
1.25 |
Received By |
jwitmer |
Date |
2003-01-16 |
Time |
08:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2002-12-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-12-26 |
Time |
14:41 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-11-05 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-11-05 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2002-11-04 |
Time |
16:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-08-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-08-14 |
Time |
18:29 |
Rev Time |
1.25 |
Received By |
jwitmer |
Date |
2002-08-14 |
Time |
18:29 |
Sent To |
|
|
Notes |
2002-08-14 00:00:00 | BUILDING PLAN REVIEW | | PERMIT:02071609 | | ADD:1400 NORTHPOINT | | CONT: LTI DEVELOPMENT | | TEL: (561)478-1841 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1) INDICATE BUILDING TYPE, PROTECTED OR | | NON-PROTECTED, FIRE SPRINKLERED? TABLE | | 500 / OCCUPANCY VS SQ FT? | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 3) SHEET A-1.1 1 HR DIMISSING WALL DE- | | TAIL, DRYWALL NOR TRACK GO ALL THE WAY | | TO THE ROOF DECK. 705.6 | | | | 4) 705.7.1 FIRE RESISTANT JOINT SYSTEMS | | THE JOINT LEFT BETWEEN THE WALL AND | | THE FLOOR/CEILING ASSEMBLY OR CEILING/ | | ROOF ASSEMBLY SHALL BE PROTECTED BY AN | | APPROVED FIRE RESISTANT JOINT SYSTEM | | DESIGNED TO RESIST THE PASSAGE OF FIRE | | FOR A TIME PERIOD NOT LESS THAN REQUIRED | | FOR THE WALL. | | | | 5) TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY | | | | 6) 1005.2 DEAD END POCKETS. EXIT ACCESS | | SHALL BE SO ARRANGED THAT DEAD END POC- | | KETS OR HALLWAYS IN EXCESS OF 20 FT LONG | | SHALL NOT OCCUR. | | | | 7) PROVIDE ADDITIONAL INFORMATION ON | | ELECTRIC LOCKING MECHANISMS, 1012.6.1. | | PROVIDE MANUFACTURERS SPEC. | | | | 8) PROVIDE ROOM USAGE, PLEASE INDICATE | | ON FLOOR PLAN. | | | | 9)11-4.1.3(3) GROUND & FLOOR SURFACES | | ALONG ACCESSIBLE ROUTES & IN ACCESSIBLE | | ROOMS & SPACES SHALL COMPLY WITH | | 11-4.5. SEE ADDAAG A4.5.1 (GUIDELINE) | | A STATIC COEFFICIENT OF FRICTION OF 0.6 | | IS RECOMENDED FOR ACCESSIBLE ROUTES | | AND 0.8 FOR RAMPS. | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | DESCRIPTION OF THE REVISION MADE, IDEN- | | TIFYING THE SHEET OR SPECIFICATION PAGE | | WHERE THE CHANGES CAN BE FOUND, WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | FOR YOUR ANTICIPATED COOPERATION. | | JIM WITMER | | PLAN REVIEW | | TEL: (561)659-8096 EX.8412 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2003-03-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-21 |
Time |
10:06 |
Rev Time |
1.25 |
Received By |
dpalmer |
Date |
2003-03-21 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2003-03-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-18 |
Time |
10:43 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-03-18 |
Time |
10:43 |
Sent To |
|
|
Notes |
2003-03-18 00:00:00 | *************** UNSAT ****************** | | | | 1)NOTE: PLEASE SHOW AND NOTE REVISIONS | | ON ALL SHEETS. PLEASE SHOW AND LABEL | | ALL W/ CLOUDS OR TRIANGLES. | | PLEASE ALSO REVISE PANEL SCHEDULES TO | | CORRELATE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-01-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-07 |
Time |
18:06 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-01-07 |
Time |
18:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2002-11-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-11-26 |
Time |
07:04 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2002-11-26 |
Time |
07:00 |
Sent To |
|
|
Notes |
2002-11-26 00:00:00 | *************** UNSAT ************* | | | | 1)NOTE: PLEASE NOTE, NOTE FROM FIRST | | TWO REVIEWS WERE NOT MET. | | PLEASE NOTE, NO EQUIPMENT GROUNDING | | METHOD IS SHOWN BETWEEN MAINS/PANELS, | | TRANSFORMERS???? 250-24,250-30,250-122 | | ETC. | | | | 2) PLEASE TAKE OUT OLD SHEETS AND INSERT | | NEW SHEETS FOR TWO COMPLTE SETS FOR | | REVIEW. PLEASE NOTE, ONE OLD SET MAY BE | | SUBMITTED FOR REFERENCE IF NEEDED. | | | | 3)NOTE: PLEASE SEE ATTACHED LETTER PER | | FS. 553.80(2)(B) WITH RESPECT TO DESIGN | | PROFESSIONAL. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. ONCE AGAIN, IF THERE ARE ANY | | QUESTIONS, PLEASE CALL. IF A MEETING | | WOULD BE REQ`D TO GO OVER PLANS, PLEASE | | CALL. | | | | DEWEY PALMER | | ELECTRICAL PAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2002-10-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-10-31 |
Time |
11:08 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2002-10-31 |
Time |
11:07 |
Sent To |
|
|
Notes |
2002-10-31 00:00:00 | ************* UNSAT **************** | | | | 1)NOTE: PLEASE NOTE/CLARFIY MISSING | | EQUIPMENT GROUNDIGN CONDUCTORS BETWEEN | | PANELS/MAINS/TRANSFORMERS ETC. 250-142 | | 250-122,250-30 | | | | 2)NOTE: PLEASE NOTE PANEL "B" IS NOT | | SHOWN AS BEING FED FROM ANYWHERE? | | PLEASE SHOW. | | | | 3)NOTE: PLEASE NOTE NO MAIN ON LOAD SIDE | | OF TRANSFORMER INTO PANEL "A". LIGHTING | | AND APPL PANELBOARD.384-16, | | | | 4)NOTE: PLEASE SHOW WHERE GRND IS BEING | | ATTACHED FOR TRANSFORMER. 250-30 | | AND FOR MAIN DISC. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-08-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2002-08-02 |
Time |
16:26 |
Rev Time |
1.00 |
Received By |
jleahy |
Date |
2002-08-02 |
Time |
16:22 |
Sent To |
|
|
Notes |
2002-08-02 00:00:00 | CONDUIT TO TRANSFORMER HAS TWO SETS OF | | WIRES SHOWN 4-#3 AND 4-#8 ???????????? | | | | FOURTH WIRE IS IT A NEUTRAL OR A GROUND? | | | | PANELS ON THE SECONDARY OF THE TRANSFORM | | HAVE NO MAINS SEE 384-16 E!!!!!!!!!!!!!A |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2003-03-27 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-03-27 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-03-27 |
Time |
16:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2003-01-08 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-01-08 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-01-08 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-11-14 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-11-14 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-11-14 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-08-02 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-08-02 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-08-02 |
Time |
17:11 |
Sent To |
|
|
Notes |
2002-08-02 00:00:00 | 1) PLEASE INDICATE ON THE PLANS WHERE | | THE TENANT DEMISING WALLS ARE LOCATED. | | | | 2) PLANS DO INDICATE INTERIOR FINISH | | CLASSIFICATION INFORMATION FOR WALLS | | AND CEILINGS. | | | | 3) IT APPEARS THAT NOT ENOUGH | | ILLUMINATED EXIT SIGNS OR EMERGENCY | | LIGHTING EQUIPMENT ARE PRESENT WITHIN | | THE SPACE. | | | | 4) SOME DEAD-ENDS EXIST THAT MAY EXCEED | | BUILDING CODE REQUIREMENTS. | | | | 5) ROOMS SHOULD BE LABELED ON THE | | FLOOR PLAN. | | | | 6) NO MENTION OF FIRE SPRINKLERS, FIRE | | ALARM OR FIRE EXTINGUISHER EQUIPMENT | | WITHIN THE TENANT SPACE. PLEASE ADVISE | | AND REVISE AS NECESSARY. | | | | 7) PLEASE PROVIDE OCCUPANT LOAD | | CALCULATIONS. | | | | 8) PLEASE PROVIDE MORE INFORMATION ON | | ELECTRONIC LATCHES. SECURITY DEVICES | | SHALL NOT INTERFERE WITH ANY EXITING. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-03-20 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-03-20 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-03-20 |
Time |
11:13 |
Sent To |
|
|
Notes |
2003-03-20 00:00:00 | TO COMM BOARD #41 | | ELECTRICAL REVISIONS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-03-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-03-10 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-03-10 |
Time |
12:33 |
Sent To |
|
|
Notes |
2003-03-10 00:00:00 | TO COMM BOARD #29 ALL TRADES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-01-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-06 |
Time |
17:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2003-01-02 |
Time |
17:51 |
Sent To |
|
|
Notes |
2003-01-07 00:00:00 | TO COMM BOARD #19. | | | | CHECKED OFF FOR BLDG,ELEC FIRE AND PLUMB | | SEE NEW SHEETS REVISEING FLAME SPREAD | | INFO AND FLOOR PLAN. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-11-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-11-25 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-11-25 |
Time |
18:03 |
Sent To |
|
|
Notes |
2002-11-25 00:00:00 | TO | | COMM BOARD # 31./WRT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2003-03-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-03-18 |
Time |
11:24 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2003-03-18 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2003-01-16 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-16 |
Time |
12:53 |
Rev Time |
0.10 |
Received By |
pkrauss |
Date |
2003-01-16 |
Time |
12:53 |
Sent To |
|
|
Notes |
2003-01-16 00:00:00 | APPROVED MECHANICAL PERMIT 02101430 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2002-12-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-12-23 |
Time |
09:22 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2002-12-23 |
Time |
09:22 |
Sent To |
|
|
Notes |
2002-12-23 00:00:00 | PROVISO: | | | | AS PER 2001 FBC 1511.7, ROOF MOUNTED | | MECHANICAL UNITS SHALL BE MOUNTED ON | | CURBS RAISED A MINIMUM OF 8" ABOVE THE | | ROOF SURFACE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2002-10-30 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-10-30 |
Time |
11:41 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2002-10-30 |
Time |
11:16 |
Sent To |
|
|
Notes |
2002-10-30 00:00:00 | DENIED: | | | | 1.PLEASE PROVIDE EQUIPMENT SCHEDULE | | ON PLAN. | | | | 2.PROVIDE OUTSIDE AIR CALCULATIONS | | AS PER 2001 FBC(M) TABLE 403.3 OR | | ASHRAE 62-89. | | | | 3.PLEASE INDICATE DUCT SMOKE DETECTORS | | AS PER 2001 FBC(M) 606.2.1 & 606.2.2 | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-08-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-08-13 |
Time |
07:47 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2002-08-13 |
Time |
07:47 |
Sent To |
|
|
Notes |
2002-08-13 00:00:00 | DENIED: | | | | 1. THE "SYSTEM SIZING SUMMARY" INDICATES | | SYSTEMS 1A, 2 & 3.PLAN INDICATES | | SYSTEMS 1A & B, 2A, B, & C, AND 3. | | PLEASE PROVIDE SCHEDULE FOR THE RTU | | EQUIPMENT. | | | | 2. PLEASE PROVIDE OUTSIDE AIR CALCS AS | | PER 2001 FBC(M) TABLE 403.3 OR ASHRAE | | 62-89. | | | | 3. RETURN AIR DUCTS & GRILLES ARE NOT | | SIZED. | | | | 4. AREA SERVED BY RTU #3 APPEARS TO HAVE | | A RETURN AIR PLENUM. PLEASE NOTE | | AS PER 2001 FBC(M) 602.2.1, MATERIALS | | EXPOSED WITHIN PLENUMS SHALL BE NON- | | COMBUSTIBLE OR SHALL HAVE A FLAME | | SPREAD INDEX IF NOT MORE THAN 25 & A | | SMOKE-DEVELOPED INDEX OF NOT MORE | | THAN 50 WHEN TESTED IN ACCORDANCE | | WITH ASTM E 84. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-24 |
Time |
11:04 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-03-24 |
Time |
11:04 |
Sent To |
|
|
Notes |
2003-03-24 00:00:00 | REVISION OK - REMOVED F.S. AND W/HEATER | | INCREASED SIZE OF OTHER W/HEATER |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2003-03-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-03-22 |
Time |
07:19 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-03-22 |
Time |
07:19 |
Sent To |
|
|
Notes |
2003-03-22 00:00:00 | REVISION DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) SHT 3.1 FLOOR SINK NOT VENTED. SEE | | PROVISO WHEN PERMIT ISSUED. | | 2) SHT 3.2 SANITARY RISER DIAGRAM, NO | | FLOOR SINK SHOWN. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
N |
Date |
2003-01-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-11 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-01-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-11 |
Time |
15:37 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-01-11 |
Time |
15:36 |
Sent To |
|
|
Notes |
2003-01-11 00:00:00 | PASSED/PROVISO | | | | SHT'S 3.1 & 3.2, REVISION REQUIRED FOR | | FLOOR SINK NOT SHOWN FOR ROOM 106. SEE | | RED LINE CORRECTIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2002-12-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-12-16 |
Time |
18:44 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2002-12-16 |
Time |
18:44 |
Sent To |
|
|
Notes |
2002-12-16 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 11 | | | | 1) FROM PREVIOUS REVIEW: | | COVER SHEET INDICATES WAREHOUSE AND | | SHOWROOM. PLEASE SHOW SQUARE FOOTAGE FOR | | OFFICE, WAREHOUSE, AND SHOWROOM INDIVID- | | UALLY. PLEASE INDICATE PRODUCT THAT WILL | | BE ON SALES ROOM FLOOR AND WAREHOUSE. | | 2) FROM PREVIOUS REVIEW: | | PLEASE SUBMIT CALCULATIONS FOR MINIMUM | | FACILITIES PER TABLE 403.1, AND TABLE | | 1003.1 (BLDG. CODE). SHOW NUMBER OF PER- | | SONS REQUIRED FOR EACH OCCUPANCY. | | 3) FROM PREVIOUS REVIEW: | | PLEASE SUBMIT DETAILS FOR SHOWERS IN RMS | | #104, 105, & 126. SEE SECTION 11-4.21 | | SHOWER STALLS. SHOW COMPLIANCE FOR ALL | | SUBSECTIONS, 4.21.2 SIZE/CLEARANCES, | | 4.21.3 SEAT, 4.21.4 GRAB BARS, 4.21.5 | | CONTROLS, 4.21.6 SHOWER UNIT, 4.21.7 | | CURBS. FIGURES 35(A) OR (B), & FIGURE | | 57(A) OR (B). - IF BATHING FACILITIES | | ARE PROVIDED ON A SITE, THEN EACH SUCH | | PUBLIC OR COMMON USE BATHING FACILITY | | SHALL COMPLY WITH 11-4.23. SECTION | | 11-4.1.2(6). | | 4) SHT 3.2 OF 11, SANITARY RISER DIAGRAM | | FLOOR SINK NOT VENTED, AND SINK IN ROOM | | #106 IS NOT SHOWN ON RISER DIAGRAM. | | 5) MANUF. INFO. REQUIRED FOR INSTA HOT | | BEING USED. REQUIRES A LISTING. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-11-06 |
Time |
08:41 |
Rev Time |
2.50 |
Received By |
kstevens |
Date |
2002-11-06 |
Time |
08:40 |
Sent To |
|
|
Notes |
2002-11-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FBC-2001 PLUMBING | | | | 1) COVER SHEET INDICATES WAREHOUSE AND | | SHOWROOM. PLEASE SHOW SQUARE FOOTAGE FOR | | OFFICE, WAREHOUSE, AND SHOWROOM INDIVID- | | UALLY. PLEASE INDICATE PRODUCT THAT WILL | | BE ON SALES ROOM FLOOR AND WAREHOUSE. | | 2) RPZ BACKFLOW IS REQUIRED ON WATER | | SERVICE TO BLDG. | | 3) PLEASE SUBMIT CALCULATIONS FOR MINIM- | | UM FACILITIES PER TABLE 403.1, AND TABLE | | 1003.1 (BLDG CODE). SHOW NUMBER OF PER- | | SONS REQUIRED FOR EACH OCCUPANCY. | | 4) WHAT WILL BULL PEN BE USED FOR? | | 5) PLEASE SUBMIT DETAILS FOR SHOWERS IN | | #104, 105, & 126. SEE SECTION 11-4.21 | | SHOWER STALLS. SHOW COMPLIANCE FOR ALL | | SUBSECTIONS, 4.21.2 SIZE/CLEARANCES, | | 4.21.3 SEAT, 4.21.4 GRAB BARS, 4.21.5 | | CONTROLS, 4.21.6 SHOWER UNIT, 4.21.7 | | CURBS. FIGURS 35(A) OR (B), & FIGURE | | 57(A) OR (B) | | 6) SHTS 3.1 OF 11 AND 3.2 OF 11, P/T | | FROM WATER HEATERS SHALL DRAIN TO A | | FLOOR SINK. FLOOR DRAIN ARE NOT AN APPRO | | VED INDIRECT WASTE RECEPTOR. | | 7) SHT 3.2 OF 11, SANITARY AND WATER | | RISER DIAGRAMS DO NOT REFLECT THE FLOOR | | PLAN. URNALS ARE ON WALL BEHIND MOP SINK | | NOT ON THE OTHER SIDE OF ROOM. W/C'S AND | | LAVS. MISSING OFF BOTH RISERS. WATER | | HAMMER ARRESTOR LOCATION SHALL BE NEAR | | THE FIXTURE IN AN "EFFECTIVE RANGE NOT | | AT THE TOP OF RISER IN CEILING PER PDI- | | WH 201 AND MANUFACTURE INSTALLATION IN- | | STRUCTIONS. WATER HAMMER ARRESTORS ARE | | REQUIRED PER 604.9. AIR CHAMBERS ARE NOT | | APPROVED. | | 8) SHT 3.2 OF 11 WATER RISER DIAGRAM, | | WATER PIPING TO WATER HEATER BY MOP SINK | | NOT SHOWN ON RISER. | | 9) THERMAL EXPANSION CONTROL REQUIRED | | PER 607.3 AND 607.3.2. PLEASE GIVE DE- | | TAIL. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-08-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-08-12 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-08-12 |
Time |
15:18 |
Sent To |
|
|
Notes |
2002-08-12 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FBC-2001 PLUMBING | | | | 1) SHT A-1 ROOM 106 PRIVATE BATHROOM, | | PLEASE SHOW DETAILS FOR SHOWER. BACKING | | REQUIRED FOR GRAB BARS, AND SEAT FOR | | SHOWER. CURB TO BE MAX 1/2", CONTROLS | | SHALL BE WITHIN 38" TO 48" OFF FLOOR, | | SHOW WHICH WALL CONTROL AND SHOWER HEAD | | ARE ON. LAV SHALL HAVE A REMOVABLE VANI- | | TY OR BE CENTERED (2') ON THE 48"X30" | | CLEAR FLOOR SPACE. (PARALLEL APPROACH) | | PLEASE PROVIDE DETAILS FOR ADAPTABLE | | BATHROOM. 11-4.21 & ALL SUBSECTIONS | | 2) SHT A-1 BOTTLED WATER COOLER SHALL | | COMPLY WITH ARI-1010. PLEASE PROVIDE | | MANUF. INFORMATION. | | 3) SHT A-6.1 SANITARY RISER DIAG. FIX- | | TURES IN ROOM #114 (HDCP W/C, JANITOR | | SINK, URNALS, ECT SHALL NOT DRAIN INTO | | THE VENT FOR THE W/C IN THE FIRST STALL. | | PLEASE DRAIN THESE FIXTURES DOWNSTREAM | | OF THE VENT FOR THAT W/C. ALSO CHANGE | | SHT A-5 FLOOR PLAN. | | 4) SHT A-6.1 WATER RISER DIAGRAM, WATER | | HAMMER ARRESTORS SHALL BE LOCATED NEAR | | FIXTURES IN AN "EFFECTIVE RANGE" NOT AT | | THE TOP OF DROPS AS SHOWN. PDI-WH 201 | | AND MANUF. INSTALL. INSTRUCTIONS. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|