Plan Review Details - Permit 02071111
Plan Review Stops For Permit 02071111
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-30 Cont ID  
Sent By dpalmer Date 2002-12-30 Time 13:11 Rev Time 0.25
Received By dpalmer Date 2002-12-30 Time 13:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-31 Cont ID  
Sent By btrobaug Date 2002-07-31 Time 10:22 Rev Time 0.00
Received By btrobaug Date 2002-07-31 Time 08:31 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-31 Cont ID  
Sent By btrobaug Date 2002-10-31 Time 09:51 Rev Time 0.00
Received By btrobaug Date 2002-10-31 Time 09:51 Sent To P
Notes
2002-10-31 00:00:00TO P IN BOX./WRT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-07-29 Cont ID  
Sent By hmoser Date 2002-07-29 Time 19:09 Rev Time 0.50
Received By hmoser Date 2002-07-29 Time 19:09 Sent To  
Notes
2002-07-29 00:00:00PASS/PRIVISO
 1) NEED LETTER FROM MANUFACTURE STATING
 AIRHANDLER WILL NOT PRODUCE 2000 CFM.
 IN ANY CONDITION.FOR FINAL
 2) NEED FRESH AIR CALCULATIONS FOR
 ROUGH INSPECTION
 3) NEED PROGRAMMABLE THERMOSTAT FOR
 FINAL
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-11-12 Cont ID  
Sent By kstevens Date 2002-11-12 Time 10:21 Rev Time 0.50
Received By kstevens Date 2002-11-12 Time 10:21 Sent To  
Notes
2002-11-12 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-07-23 Cont ID  
Sent By btrobaug Date 2002-10-31 Time 09:51 Rev Time 0.33
Received By jleech Date 2002-07-23 Time 20:13 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-08-15 Cont ID  
Sent By btrobaug Date 2002-07-31 Time 10:22 Rev Time 3.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-08-15 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02071111
 ADD: 2645 SANDY CAY
 CONT: TAZ CONSTRUCTION
 TEL: (954)340-1744
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ******PROVISO*****
  
 PROVIDE MISSING PRODUCT REPORTS BEFORE
 FRAMING INSPECTION:
 A) SWING DOORS
 B) GLASS BLOCK
 C) ROOFING ASSEMBLIES
 CONNECTION DETAIL 15 OF SHEET A5, ON A
 SINGLE MEMBER TRUSS THE VALUES GIVEN
 FOR THE TA-14R OF 1520 @ EACH STRAP
 EQUAL 3040 , A DERATING OF 20% IS RECOME
 NDED BY USP OR A VALUE OF 2432 PLUS 785
 FOR THE MSH218 OR A TOTAL ALLOWABLE LOAD
 OF 3217, THIS IS LIGHT VS THE 3833
 MAXIMUM UPLIFT.
  
 THE USE OF A 2 MEMBER MSH418 FACE MOUNT
 WITH (2) TA-14R WITH REDUCTION ADEQUATE-
 LY MEETS THE REQUIRED RESISTANCE FOR
 UPLIFT.
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop Z ZONING
Rev No 1 Status P Date 2002-07-19 Cont ID  
Sent By sgraham Date 2002-07-19 Time 14:59 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***