Plan Review Details - Permit 02071111
Plan Review Stops For Permit 02071111 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-30 |
Time |
13:11 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-30 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-07-31 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-07-31 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-07-31 |
Time |
08:31 |
Sent To |
R |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-10-31 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-10-31 |
Time |
09:51 |
Sent To |
P |
|
Notes |
2002-10-31 00:00:00 | TO P IN BOX./WRT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-07-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-07-29 |
Time |
19:09 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2002-07-29 |
Time |
19:09 |
Sent To |
|
|
Notes |
2002-07-29 00:00:00 | PASS/PRIVISO | | 1) NEED LETTER FROM MANUFACTURE STATING | | AIRHANDLER WILL NOT PRODUCE 2000 CFM. | | IN ANY CONDITION.FOR FINAL | | 2) NEED FRESH AIR CALCULATIONS FOR | | ROUGH INSPECTION | | 3) NEED PROGRAMMABLE THERMOSTAT FOR | | FINAL | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT 8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-11-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-11-12 |
Time |
10:21 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2002-11-12 |
Time |
10:21 |
Sent To |
|
|
Notes |
2002-11-12 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-07-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
09:51 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-07-23 |
Time |
20:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2002-08-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-07-31 |
Time |
10:22 |
Rev Time |
3.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-08-15 00:00:00 | | | BUILDING PLAN REVIEW | | PERMIT: 02071111 | | ADD: 2645 SANDY CAY | | CONT: TAZ CONSTRUCTION | | TEL: (954)340-1744 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | ******PROVISO***** | | | | PROVIDE MISSING PRODUCT REPORTS BEFORE | | FRAMING INSPECTION: | | A) SWING DOORS | | B) GLASS BLOCK | | C) ROOFING ASSEMBLIES | | CONNECTION DETAIL 15 OF SHEET A5, ON A | | SINGLE MEMBER TRUSS THE VALUES GIVEN | | FOR THE TA-14R OF 1520 @ EACH STRAP | | EQUAL 3040 , A DERATING OF 20% IS RECOME | | NDED BY USP OR A VALUE OF 2432 PLUS 785 | | FOR THE MSH218 OR A TOTAL ALLOWABLE LOAD | | OF 3217, THIS IS LIGHT VS THE 3833 | | MAXIMUM UPLIFT. | | | | THE USE OF A 2 MEMBER MSH418 FACE MOUNT | | WITH (2) TA-14R WITH REDUCTION ADEQUATE- | | LY MEETS THE REQUIRED RESISTANCE FOR | | UPLIFT. | | BUILDING PLAN REVIEW | | JIM WITMER |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-07-19 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-07-19 |
Time |
14:59 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|