Plan Review Details - Permit 02061385
Plan Review Stops For Permit 02061385
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-09-04 Cont ID  
Sent By jwitmer Date 2002-09-04 Time 15:39 Rev Time 1.50
Received By jwitmer Date 2002-09-04 Time 15:39 Sent To  
Notes
2002-09-04 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02061385
 ADD: 2301 CENTREPARK WEST
 CONT: LEIGHTON MCGINN
 TEL: (561)863-4455
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ******PROVISO******
  
 1)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING MULLION
 REPORT. PROVIDE BY BUCK INSPECTION.
  
 3)1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 4)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE. MULLIONS
 THAT ARE TO BE PART OF A LARGE MISSLE
 SYSTEM ARE REQUIRED TO BE CLIPPED.
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-07-23 Cont ID  
Sent By jwitmer Date 2002-07-23 Time 17:04 Rev Time 3.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-07-23 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02061385
 ADD: 2301 CENTREPARK W DRIVE
 CONT: LEIGHTON MCGINN CO
 TEL: (561)863-4455
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 PROVIDE 2 CURRENT COPIES OF SIGNED &
 SEALED SURVEYS WITH PROPOSED IMPROVEMENT
 TO BE COMPLETED.
  
 PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION, CITY CODE REQUIRES
 AN ADDITIONAL A-9 FLOODZONE BASE 13'+
 6" CITY CODE, MINIMUM 13'6", FINISH
 FLOOR & A/C PADS.
  
 11-4.1.3(1) AT LEAST ONE ACCESSIBLE
 ROUTTE COMPLYING WITH 11-4.3 SHALL
 CONNECT ACCESSIBLE BUILDING OR FACILITY
 ENETRANCES WITH ALL ACCESSIBLE SPACES
 AND ELEMENTS WITHIN THE BUILDING OR
 FACILITY.
  
 11-4.1.3(3) GROUND & FLOOR SURFACES
 ALONG ACCESSIBLE ROUTES & IN ACCESSIBLE
 ROOMS & SPACES SHALL COMPLY WITH
 11-4.5. SEE ADDAAG A4.5.1 (GUIDELINE)
 A STATIC COEFFICIENT OF FRICTION OF 0.6
 IS RECOMENDED FOR ACCESSIBLE ROUTES
 AND 0.8 FOR RAMPS.
  
 1503.4.4 PROTECTION AGAINST DECAY &
 TURMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 1511.7 ROOF MOUNTED MECHANICAL UNIT
 S SHALL BE MOUNTED ON CURBS RAISED A
 MINIMUM OF 8 INCHES ABOVE THE ROOF SUR-
 FACE, OR WHERE ROOFING MATERIALS EXTEND
 BENEATH THE UNIT, ON RAISED EQUIPMENT
 SUPPORTS PROVIDING A MINIMUM CLEARENCE
 HEIGTH IN ACCORDANCE WITH TABLE 1511.7.
  
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.MISSING REPORTS:
 A)WINDOWS
 B)MULLIONS
 C)DOORS, EXTERIOR
 D)ROOFING ASSEMBLIES
  
 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
  
 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
  
 FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
  
 2504.2.2 INSTALLATION OF EXTERIOR
 LATHING AND FRAMING SHALL COMPLY WITH
 ASTM C-1063.
  
 SHEET A-3 DETAIL #3 FAN ROOF MOUNT
 DETAIL NO FASTENING INFO?
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLANS DO NOT INDI-
 CATE WITH STAMP FEES WERE PAID, RECEIPT
 FROM COUNTY IN PACKAGE?

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-10 Cont ID  
Sent By dpalmer Date 2002-07-10 Time 07:07 Rev Time 0.00
Received By dpalmer Date 2002-07-09 Time 16:47 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2002-07-18 Cont ID  
Sent By mamini Date 2002-07-18 Time 08:10 Rev Time 1.00
Received By mamini Date 2002-07-18 Time 08:09 Sent To  
Notes
2002-07-18 00:00:00N/A :
 1. SEE PERMIT # 02071110 FOR CIVIL/SITE
 WORK REVIEW AND PERMITTING.
 IF ANY QUESTION PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2002-07-01 Cont ID  
Sent By mamini Date 2002-07-01 Time 10:13 Rev Time 5.00
Received By mamini Date 2002-07-01 Time 10:13 Sent To  
Notes
2002-07-01 00:00:00FAILED:
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR CIVIL/SITE
 WORKS WILL BE REQUIRED.
 2. ALL OFF-STREET PARKING MUST BE
 PAINTED WITH DOUBLE 4" WHITE FOR REGULAR
 PARKING STALLS.
 3. POLLUTION / EROSION PLAN MUST BE
 INSTALLED IN FIELD PRIOR TO ANY EARTH/
 SITE WORKS.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-09-05 Cont ID  
Sent By mcarsill Date 2002-09-05 Time 09:29 Rev Time 0.00
Received By mcarsill Date 2002-09-05 Time 09:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-07-10 Cont ID  
Sent By mcarsill Date 2002-07-03 Time 09:27 Rev Time 0.00
Received By mcarsill Date 2002-07-03 Time 09:27 Sent To  
Notes
2002-07-03 00:00:001) SITE PLAN MUST SHOW ANY NEW OR
 EXISTING FIRE HYDRANT LOCATIONS.
  
 2) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE SPRINKLER SYSTEM INSTALLATION.
 THE FIRE DEPARTMENT SPRINKLER CONNECTION
 MUST BE WITHIN 150 FEET FROM A FIRE
 HYDRANT.
  
 3) ELECTRONIC SWITCHES, CHAIN AND LOCK
 REQUIRED ON BACKFLOW DEVICE.
  
 4) TENANT SEPARATION WALLS ARE TO MEET
 FLORIDA BUILDING CODE REQUIREMENTS.
  
 5) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM SYSTEM. FIRE ALARM SYSTEM
 TO BE CLASS A OR FULLY ADDRESSABLE.
  
 6) DUCT SMOKE DETECTORS ARE REQUIRED
 ON ALL AIR HANDLING UNITS 2000 CFM OR
 ABOVE.
  
 7) SEPARATE PLANS AND PERMITS WILL BE
 REQUIRED FOR EACH TENANT FIT-UP
 PLANNED FOR THE BUILDING.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-26 Cont ID  
Sent By pkrauss Date 2002-08-26 Time 09:08 Rev Time 0.35
Received By pkrauss Date 2002-08-26 Time 09:00 Sent To  
Notes
2002-08-26 00:00:00SEE PROVISO BY NANCY DENMARK DATED
 7-2-02.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-07-02 Cont ID  
Sent By ndenmark Date 2002-07-02 Time 06:23 Rev Time 0.33
Received By ndenmark Date 2002-07-02 Time 06:23 Sent To  
Notes
2002-07-02 00:00:00PROVISO:
 SHELL BUILDING ONLY
  
 CONDENSING UNIT ROOF STANDS HEIGHT WILL
 BE DETERMINED BY WIDTH OF EQUIPMENT TO
 BE ATTACHED, SEE M0-1.
  
 MAINTAIN 10' MINIMUM SEPARATION BETWEEN
 GRAVITY INTAKE HOODS AND PLUMBING STACKS

Review Stop P PLUMBING
Rev No 2 Status N Date 2002-08-23 Cont ID  
Sent By kstevens Date 2002-08-23 Time 18:08 Rev Time 0.00
Received By kstevens Date 2002-08-23 Time 18:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-07-11 Cont ID  
Sent By kstevens Date 2002-07-11 Time 08:46 Rev Time 0.00
Received By kstevens Date 2002-07-11 Time 08:46 Sent To  
Notes
2002-07-11 00:00:00PASSED/PROVISO
  
 AIR HAMMER ARRESTORS SHALL BE LOCATED
 NEAR FIXTURE NOT AT TOP OF DROP

Review Stop Z ZONING
Rev No 2 Status P Date 2002-08-16 Cont ID  
Sent By sgraham Date 2002-08-16 Time 14:10 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-06-25 Cont ID  
Sent By sgraham Date 2002-06-25 Time 08:51 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-06-25 00:00:001. SITE PLAN DOES NOT MATCH APPROVED
 SITE PLAN.
 2. NEED MINOR AMENDMENT FOR 2ND SIGN
 3.RE-CALUCATED PROJECT DATA