Plan Review Stops For Permit 02061166 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-01-23 |
Time |
06:16 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-01-23 |
Time |
06:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-08-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-08-26 |
Time |
17:54 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2002-08-26 |
Time |
17:54 |
Sent To |
R |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-07-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-06-29 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-07-03 |
Time |
06:47 |
Sent To |
R |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-08-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-08-28 |
Time |
12:02 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2002-08-28 |
Time |
11:56 |
Sent To |
R |
|
Notes |
2002-08-28 00:00:00 | PROVISO: | | | | WHERE MULTIPLE AIR HANDLING SYSTEMS | | SHARE A COMMON SUPPLY OR RETURN AIR | | DUCTS OR PLENUMS WITH A COMBINED | | CAPACITY GREATER THAN 2,000 CFM, FAN | | SHUTDOWN IS REQUIRED IN ACCORDANCE WITH | | 2001FBC(M) 606.2.1 OR 606.4. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-06-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-06-29 |
Time |
10:12 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2002-06-29 |
Time |
10:12 |
Sent To |
E |
|
Notes |
2002-06-29 00:00:00 | PASS/PRIVISO | | 1) NEED FRESH AIR CALCULATIONS FOR | | ROUGH INSPECTION | | 2) NEED EVAP.COIAL MODEL NUMBER FOR | | FINAL INSPECTION | | 3) NEED FAN SHUTDOWN FOR FINAL | | INSPECTION SECTION 606.2.2 FBC.2001 | | PLAN REVIEW BY HAROLD MOSER | | (561)659-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-01-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-22 |
Time |
15:53 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-01-22 |
Time |
15:53 |
Sent To |
|
|
Notes |
2003-01-22 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2003-01-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-18 |
Time |
06:20 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-01-18 |
Time |
05:48 |
Sent To |
|
|
Notes |
2003-01-18 00:00:00 | DENIED | | REFERENCE: FBC-2001 | | | | 1) REVISION IS MISSING AUTOMATIC CLOTHES | | WASHER. THIS FIXTURE IS REQUIRED PER | | TABLE 403.1 | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-08-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-08-27 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-08-27 |
Time |
15:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-06-22 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2002-06-22 |
Time |
10:12 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-06-22 |
Time |
10:12 |
Sent To |
|
|
Notes |
2002-06-22 00:00:00 | DENIED; | | 1.AUTOMATIC CLOTHES WASHER MISSING FROM | | PLUMBING RISER. | | 2.PAGE S-1 FOOTER PLAN SHOWS 3' VENT IN | | BLOCK WALL AT (ACW). WILL NOT FIT. FBC | | 2001 REQUIRES 1 2" VENT THRU ROOF. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT 8369 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2002-08-26 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-08-28 |
Time |
12:17 |
Rev Time |
4.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-08-26 00:00:00 | ************BUILDING PROVISO************ | | | | 1)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - ARCHED TOP FIXED GLASS WINDOWS AS | | SHOWN ON ARCHITECTURAL DRAWINGS | | | | 2) PROVIDE A SOIL BEARING CAPACITY TEST | | REPORT SIGNED AND SEALED BY ENGINEER, | | PRIOR TO FIRST INSPECTION. | | | | 3) PROVIDE MANUFACTURER'S SPECIFICATIONS | | AND UL LISTING FOR GLASS BLOCK WHICH | | INDICATES A ONE HOUR FIRE RATING. | | | | 4) PROVIDE (2) PRODUCT APPROVALS, KEY | | PLANS AND INSTALLATION SCHEDULES | | INDICATING THE SPECIFIC TYPES OF ANCHORS | | TO BE USED FOR STORM PANELS. A SEPARATE | | PERMIT WITH ADDITIONAL FEES IS REQUIRED. | | | | 5) PLEASE INDICATE THE INTERNAL PRESSURE | | COEFFICIENT ON THE PLANS FOR FUTURE | | SUBMITTALS. IT IS + OR - .18 FOR | | ENCLOSED STRUCTURES. | | | | 6) PLEASE CORRECT THE ROOF SHEATHING | | NAIL SPACING LISTED ON SHEETS GN-1, S-2 | | AND S-3 OF THE PLANS FOR FUTURE | | SUBMITTALS. IT IS 6"O.C.INTERMEDIATE AND | | 6"O.C.EDGES IN ZONES 1&2 AND 6"O.C. | | INTERMEDIATE AND 4"O.C. EDGES IN ZONE 3. | | SEE CITY AMENDMENTS TO FBC TABLE 2306.1. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2002-08-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-07-15 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2002-08-05 |
Time |
12:06 |
Sent To |
|
|
Notes |
2002-08-05 00:00:00 | CHECKLIST: | | SEE COMMENTS ON PERMIT #02061148 FOR | | 6533 COMPASS ROSE CT (LOT 12). |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-06-20 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-06-20 |
Time |
12:33 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|