Plan Review Details - Permit 02061166
Plan Review Stops For Permit 02061166
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-01-23 Cont ID  
Sent By dpalmer Date 2003-01-23 Time 06:16 Rev Time 0.25
Received By dpalmer Date 2003-01-23 Time 06:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-26 Cont ID  
Sent By btrobaug Date 2002-08-26 Time 17:54 Rev Time 0.50
Received By btrobaug Date 2002-08-26 Time 17:54 Sent To R
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-15 Cont ID  
Sent By hmoser Date 2002-06-29 Time 10:24 Rev Time 0.00
Received By btrobaug Date 2002-07-03 Time 06:47 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-28 Cont ID  
Sent By pkrauss Date 2002-08-28 Time 12:02 Rev Time 0.35
Received By pkrauss Date 2002-08-28 Time 11:56 Sent To R
Notes
2002-08-28 00:00:00PROVISO:
  
 WHERE MULTIPLE AIR HANDLING SYSTEMS
 SHARE A COMMON SUPPLY OR RETURN AIR
 DUCTS OR PLENUMS WITH A COMBINED
 CAPACITY GREATER THAN 2,000 CFM, FAN
 SHUTDOWN IS REQUIRED IN ACCORDANCE WITH
 2001FBC(M) 606.2.1 OR 606.4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-29 Cont ID  
Sent By hmoser Date 2002-06-29 Time 10:12 Rev Time 0.50
Received By hmoser Date 2002-06-29 Time 10:12 Sent To E
Notes
2002-06-29 00:00:00PASS/PRIVISO
 1) NEED FRESH AIR CALCULATIONS FOR
 ROUGH INSPECTION
 2) NEED EVAP.COIAL MODEL NUMBER FOR
 FINAL INSPECTION
 3) NEED FAN SHUTDOWN FOR FINAL
 INSPECTION SECTION 606.2.2 FBC.2001
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-01-22 Cont ID  
Sent By kstevens Date 2003-01-22 Time 15:53 Rev Time 0.33
Received By kstevens Date 2003-01-22 Time 15:53 Sent To  
Notes
2003-01-22 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-01-18 Cont ID  
Sent By kstevens Date 2003-01-18 Time 06:20 Rev Time 0.50
Received By kstevens Date 2003-01-18 Time 05:48 Sent To  
Notes
2003-01-18 00:00:00DENIED
 REFERENCE: FBC-2001
  
 1) REVISION IS MISSING AUTOMATIC CLOTHES
 WASHER. THIS FIXTURE IS REQUIRED PER
 TABLE 403.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-08-27 Cont ID  
Sent By kstevens Date 2002-08-27 Time 15:25 Rev Time 0.00
Received By kstevens Date 2002-08-27 Time 15:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-22 Cont ID  
Sent By jleech Date 2002-06-22 Time 10:12 Rev Time 0.33
Received By jleech Date 2002-06-22 Time 10:12 Sent To  
Notes
2002-06-22 00:00:00DENIED;
 1.AUTOMATIC CLOTHES WASHER MISSING FROM
 PLUMBING RISER.
 2.PAGE S-1 FOOTER PLAN SHOWS 3' VENT IN
 BLOCK WALL AT (ACW). WILL NOT FIT. FBC
 2001 REQUIRES 1 2" VENT THRU ROOF.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT 8369

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-26 Cont ID  
Sent By pkrauss Date 2002-08-28 Time 12:17 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-26 00:00:00************BUILDING PROVISO************
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - ARCHED TOP FIXED GLASS WINDOWS AS
 SHOWN ON ARCHITECTURAL DRAWINGS
  
 2) PROVIDE A SOIL BEARING CAPACITY TEST
 REPORT SIGNED AND SEALED BY ENGINEER,
 PRIOR TO FIRST INSPECTION.
  
 3) PROVIDE MANUFACTURER'S SPECIFICATIONS
 AND UL LISTING FOR GLASS BLOCK WHICH
 INDICATES A ONE HOUR FIRE RATING.
  
 4) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS. A SEPARATE
 PERMIT WITH ADDITIONAL FEES IS REQUIRED.
  
 5) PLEASE INDICATE THE INTERNAL PRESSURE
 COEFFICIENT ON THE PLANS FOR FUTURE
 SUBMITTALS. IT IS + OR - .18 FOR
 ENCLOSED STRUCTURES.
  
 6) PLEASE CORRECT THE ROOF SHEATHING
 NAIL SPACING LISTED ON SHEETS GN-1, S-2
 AND S-3 OF THE PLANS FOR FUTURE
 SUBMITTALS. IT IS 6"O.C.INTERMEDIATE AND
 6"O.C.EDGES IN ZONES 1&2 AND 6"O.C.
 INTERMEDIATE AND 4"O.C. EDGES IN ZONE 3.
 SEE CITY AMENDMENTS TO FBC TABLE 2306.1.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-08-05 Cont ID  
Sent By btrobaug Date 2002-07-15 Time 13:41 Rev Time 0.00
Received By jgomez Date 2002-08-05 Time 12:06 Sent To  
Notes
2002-08-05 00:00:00CHECKLIST:
 SEE COMMENTS ON PERMIT #02061148 FOR
 6533 COMPASS ROSE CT (LOT 12).

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-20 Cont ID  
Sent By sgraham Date 2002-06-20 Time 12:33 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***