Plan Review Details - Permit 02061161
Plan Review Stops For Permit 02061161
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-03 Cont ID  
Sent By btrobaug Date 2002-07-03 Time 17:45 Rev Time 0.00
Received By btrobaug Date 2002-07-03 Time 17:35 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-02-12 Cont ID  
Sent By rregueir Date 2003-02-12 Time 19:22 Rev Time 0.50
Received By rregueir Date 2003-02-12 Time 19:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-07-02 Cont ID  
Sent By hmoser Date 2002-07-02 Time 18:28 Rev Time 0.50
Received By hmoser Date 2002-07-02 Time 18:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-25 Cont ID  
Sent By jleech Date 2002-06-25 Time 17:22 Rev Time 0.33
Received By jleech Date 2002-06-25 Time 17:22 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-09-27 Cont ID  
Sent By jgomez Date 2002-09-27 Time 10:51 Rev Time 3.00
Received By jgomez Date 2002-09-27 Time 10:51 Sent To  
Notes
2002-09-27 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-SHEET A-5: REVISE HEIGHT OF HANDRAIL.
 SEE SEC. 1007.5.1 FBC 2001.
 3-SHEET A-6: A)SPECIFY FIREBLOCKING AT
 SECTION A/A-6. SEC. 2305.1.4 FBC 2001.
 B)PROVIDE GENERAL SPECS FOR REQUIRED
 FIREBLOCKING AT ALL CONCEALED SPACES
 AS REQUIRED BY SEC. 2305.1.4 FBC 2001.
 C)GARAGE BUCK DETAIL: SPECIFY LENGTH OF
 ANCHOR BOLT AND SIZE OF WASHER. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC.
 4-SHEET A-7: A)REVISE STAIR KEY NOTE #1.
 HANDRAIL TO BE BET. 34" AND 36". SEE
 SEC. 1007.5.1 FBC 2001.
 B)NOTE #9: CLARIFY SIZE OF LEDGER. SEE
 STRUCTURAL DRAWINGS.
 5-SHEET S-1: REVISE LINTEL SCHEDULE TO
 MATCH PLANS. CHECK LINTEL NUMBER AND
 SIZE OF OPENINGS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 B)SPECIFY HOW LONG ARE THE ANCHOR BOLTS
 FOR WOOD COLUMNS BOTTOM CONNECTORS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 C)CLARIFY REINFORCING FOR FOOTING F5530.
 SEE FOOTING SCHEDULE. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 6-SHEET S-2: A)REVISE TRUSS CONNECTOR
 SCHEDULE TO MATCH USP PUBLISHED VALUES
 PROVIDE ENGINEER'G CALCS FOR DIFFERENT
 VALUES. SEC. 104.2.1.2 CITY AMENDMENTS
 B)SPECIFY FIRECUT REQUIREMENTS ON THE
 STRUCTURAL WALL SECTIONS. SEC. 2305.4
 C)TYPICAL CONCRETE MASONRY WALL DETAIL:
 CLARIFY SIZE OF REINFORCEMENT FOR BB.
 1#7 OR 1#5. SEE BEAM SCHEDULE.
 D)SPECIFY CONNECTORS FOR GIRDER TRUSS AT
 GARAGE ROOF.
 E)SECTION 1 AND SECTION 2 HAVE DIFFERENT
 SPECS. CLARIFY/REVISE AS REQUIRED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 7-SHEET S-3: A)REVISE TRUSS CONNECTOR
 SCHEDULE. SEE COMMENT A ABOVE.
 B)ROOF SHEATHING & NAILING NOTE AND
 DIAPHRAGM SCHEDULE SPECS DON'T MATCH.
 REVISE/CLARIFY AS REQUIRED.
 C)CONNECTORS SPECIFIED FOR SOME GIRDER
 TRUSSES DON'T RESIST CALCULATED UPLIFT
 LOADS. REVISE AS REQUIRED. SEC. 104.2.
 1.2 CITY AMENDMENTS TO FBC 2001.
 8-PROVIDE STRUCTURAL DETAIL AT RECESSED
 WINDOWS TO ALLOW FOR STORM SHUTTERS
 INSTALLATION. SEE PRODUCT APPROVAL FOR
 LIMITAIONS AND ADDITIONAL ENGINEERING
 REQUIRED. SEC. 104.2.1.2 CITY AMEND.
 9-IDENTIFY ROOF NAILING ZONES IN ROOF
 FRAMING PLANS. SEE TABLE 2306.1 CITY
 AMENDMENTS TO FBC 2001.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-08-12 Cont ID  
Sent By btrobaug Date 2002-07-03 Time 17:45 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-12 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 PROVIDE A SOIL BEARING REPORT.
  
 3) THE SOIL STATEMENT ON SHEET S1 STATES
 THAT A SEALED LETTER FROM THE ENGINEER
 OF RECORD WILL BE SUBMITTED ATTESTING
 THAT THE SITE HAS BEEN OBSERVED AND THE
 FOUNDATION CONDITIONS ARE SIMILAR TO
 THOSE UPON WHICH THE THE DESIGN HAS BEEN
 BASED.
  
 4) THE BONUS ROOM IS REQUIRED TO BE
 PERMANETLY MARKED ON THE PLANS THAT IT
 IS NOT TO BE USED FOR SLEEPING PURPOSES
 AND THE ROOM CAN NOT HAVE A CLOSET.
 OPENINGS FROM A GARAGE DIRECTLY INTO A
 ROOM USED FOR SLEEPING PURPOSES IS NOT
 PERMITTED PER 2001 FBC SEC.411.2.8.
  
 5) THE WINDOW (H) IN THE FIRST FLOOR
 BATHROOM IS REQUIRED TO HAVE TEMPERED
 GLASS PER FBC 2405.2.1 (2).
  
 6) INDICATE ON THE PLANS THAT THE BONUS
 ROOM WALLS ARE INSULATED.
  
 7) PLEASE CHANGE NOTE 6 UNDER GENERAL
 NOTES ON SHEET A2 TO REFERENCE THE 2001
 FLORIDA PLUMBING CODE.
  
 8) THE CONDITIONED AREA LISTED ON THE
 ENERGY CALCULATIONS DIFFERS FROM THE
 A/C AREA GIVEN ON THE PLANS. PLEASE
 CORRECT.
  
 9) SHEET S-2 INDICATES A P3 COLUMN BELOW
 THE FLOOR TRUSSES,HOWEVER, NOTHING IS
 SHOWN AT THIS LOCATION ON THE FOUNDATION
 PLAN ON S-1. PLEASE CLARIFY. SHEET A-1
 INDICATES A STRUCTURAL COLUMN,#33 IN THE
 KEY NOTES AT THIS LOCATION.
  
 10) FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
 PLEASE INDICATE ON PLANS.
  
 11) 2305.2.2 FLOOR/CEILING ASSEMBLIES
 SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL-
 ING ASSEMBLIES SEPERATING USEABLE SPACE
 INTO 2 OR MORE APPROXIMATE AREAS WITH NO
 AREA GREATER THAN 500 SQ FT. DRAFTSTOP-
 PING SHALL BE PROVIDED PARALLEL TO THE
 MAIN FRAMING MEMBERS. PLEASE INDICATE
 THE LOCATIONS AND MATERIALS THAT WILL BE
 USED ON THE PLANS.
  
 12) SECTIONS #1 AND #3 ON S-2 SHOW A
 CONCRETE TIE BEAM WITH FOUR REINFORCING
 BARS. THE REST OF THE PLANS INDICATE
 SINGLE BEAM BLOCK WITH ONE BAR. PLEASE
 CLARIFY.
  
 13) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - DOUBLE ENTRY DOORS (THE ONES SUBMITTED
 ARE ILLEGIBLE)
 - SINGLE HUNG WINDOWS (THE COVER SHEET
 DOES NOT MATCH THE REST OF THE PAGES,
 WHICH ARE EXPIRED)
 - MULLIONS (EXPIRED)
  
 14) STORM PANELS: NO INSTALLATION
 SCHEDULE WAS SUBMITTED. THE KEY PLAN IS
 FOR A GARAGE LEFT MODEL AND THIS IS A
 GARAGE RIGHT MODEL. THE OPENING SIZES
 ON THE PLANS DIFFER FROM THOSE ON THE
 KEY PLAN. PLEASE CORRECT.
  
 15) THE NAILS AND SPACING LISTED FOR THE
 FLOOR ON SECTION 2 ON SHEET S-2 DOES NOT
 CORRESPOND WITH THE FLOOR DIAPHRAGM
 NAILING SPECIFIED IN THE SCHEDULE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-20 Cont ID  
Sent By sgraham Date 2002-06-20 Time 12:34 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***