Plan Review Details - Permit 02061158
Plan Review Stops For Permit 02061158
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-28 Cont ID  
Sent By dpalmer Date 2002-06-28 Time 06:15 Rev Time 0.00
Received By dpalmer Date 2002-06-28 Time 06:15 Sent To B
Notes
2002-06-28 00:00:00************** NOTE**************
  
 1)NOTE: PLEASE NOTE PLANS ARE REDLINED
 FOR MANY MISSING ITEMS.
  
 210-52
 210-52H
 210-52D
 110-26
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-27 Cont ID  
Sent By hmoser Date 2002-06-27 Time 18:31 Rev Time 0.50
Received By hmoser Date 2002-06-27 Time 18:31 Sent To  
Notes
2002-06-27 00:00:00PASS/PRIVISO
 1) VARIFY TYPE OF VENTILATION USED FOR
 FRESH AIR.NATURAL SECTION 402 OR
 MECHANICAL SECTION 403 FBC.2001
 2) NEED CALCULATIONS FOR TYPE OF
 VENTILATION USED
 3) NEED FAN SHUTDOWN FOR FINAL
 INSPECTION SECTION 606.2.2 FBC 2001
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-12-23 Cont ID  
Sent By kstevens Date 2002-12-23 Time 13:59 Rev Time 0.25
Received By kstevens Date 2002-12-23 Time 13:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-12-21 Cont ID  
Sent By kstevens Date 2002-12-21 Time 07:55 Rev Time 0.50
Received By kstevens Date 2002-12-21 Time 07:55 Sent To  
Notes
2002-12-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) BATH #3 TUB NOT VENTED. VENT SHALL BE
 BETWEEN W/C AND TUB.
 2) ALL CHANGES ON SIGNED AND SEALED
 REVISIONS SHALL BE DATED AND INITIALED
 BY THE ARCHITECT OF RECORD.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-22 Cont ID  
Sent By jleech Date 2002-06-22 Time 09:25 Rev Time 0.33
Received By jleech Date 2002-06-22 Time 09:25 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-07-19 Cont ID  
Sent By lhatten Date 2002-07-19 Time 09:08 Rev Time 2.50
Received By lhatten Date 2002-07-18 Time 09:07 Sent To  
Notes
2002-07-19 00:00:00REVIEW & STAMPED PLANS 07/18/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-20 Cont ID  
Sent By sgraham Date 2002-06-20 Time 12:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***