Plan Review Details - Permit 02061148
Plan Review Stops For Permit 02061148
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-01-23 Cont ID  
Sent By dpalmer Date 2003-01-23 Time 06:13 Rev Time 0.25
Received By dpalmer Date 2003-01-23 Time 06:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-26 Cont ID  
Sent By btrobaug Date 2002-08-26 Time 06:50 Rev Time 0.00
Received By btrobaug Date 2002-08-23 Time 16:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-03 Cont ID  
Sent By hmoser Date 2002-06-29 Time 11:33 Rev Time 0.00
Received By btrobaug Date 2002-07-03 Time 16:15 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-26 Cont ID  
Sent By pkrauss Date 2002-08-26 Time 08:22 Rev Time 0.35
Received By pkrauss Date 2002-08-26 Time 08:16 Sent To  
Notes
2002-08-26 00:00:00RESTAMP

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-29 Cont ID  
Sent By hmoser Date 2002-06-29 Time 11:27 Rev Time 0.50
Received By hmoser Date 2002-06-29 Time 11:27 Sent To E
Notes
2002-06-29 00:00:00PASS/PRIVISO
 1) NEED FRESH AIR CALCULATIONS FOR
 ROUGH INSPECTION
 2) NEED EVAP.COIAL MODEL NUMBER FOR
 FINAL INSPECTION
 3) NEED FAN SHUTDOWN FOR FINAL
 INSPECTION SECTION 606.2.2 FBC.2001
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 5 Status P Date 2003-01-22 Cont ID  
Sent By kstevens Date 2003-01-22 Time 15:52 Rev Time 0.33
Received By kstevens Date 2003-01-22 Time 15:51 Sent To  
Notes
2003-01-22 00:00:00REVISION OK -SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-01-18 Cont ID  
Sent By kstevens Date 2003-01-18 Time 05:38 Rev Time 0.33
Received By kstevens Date 2003-01-18 Time 05:38 Sent To  
Notes
2003-01-18 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-01-18 Cont ID  
Sent By kstevens Date 2003-01-18 Time 05:27 Rev Time 0.50
Received By kstevens Date 2003-01-18 Time 05:27 Sent To  
Notes
2003-01-18 00:00:00DENIED
 REFERENCE: FBC-2001
  
 1) REVISION IS MISSING AUTOMATIC CLOTHES
 WASHER. THIS FIXTURE IS REQUIRED PER
 TABLE 403.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-08-27 Cont ID  
Sent By kstevens Date 2002-08-27 Time 14:46 Rev Time 0.00
Received By kstevens Date 2002-08-27 Time 14:46 Sent To  
Notes
2002-08-27 00:00:00REVERSE SANT RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-22 Cont ID  
Sent By jleech Date 2002-06-22 Time 09:54 Rev Time 0.33
Received By jleech Date 2002-06-22 Time 09:54 Sent To  
Notes
2002-06-22 00:00:00DENIED;L
 1.AUTOMATIC CLOTHES WASHER MISSING FROM
 PLUMBING RISER DIAGRAM.
 2.PAGE S-1 FOOTER PLAN. SHOWS SHOWS A 3"
 VENT THRU ROOF AT (ACW) 3" STACKS PIPE
 IS TO LARGE TO FIT IN A BLOCK WALL.
 FBC 2001 ONLY REQUIES 1 2" VENT THRU
 THE ROOF.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8369

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2002-09-09 Cont ID  
Sent By rmcdouga Date 2002-09-09 Time 11:25 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-09-09 00:00:00PROVISO SUBMITTALS:
 SUBMITTAL FOR THE FIRE RATED GLASS BLOCK
 IS O.K.
 ALL OF THE INFORMATION REQUIRED FOR THE
 STORM PANELS WAS NOT SUBMITTED AT THE
 TIME THE PERMIT FOR THE STRUCTURE WAS
 ISSUED. THEREFORE, AS STATED IN ITEM #3
 OF THE PROVISO, A SEPARATE PERMIT WITH
 ADDITIONAL FEES WILL BE REQUIRED. PLEASE
 SUBMIT THE REQUIRED INFORMATION AT THAT
 TIME. (PRODUCT APPROVALS,INSTALLATION
 SCHEDULE AND KEY PLAN)

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-23 Cont ID  
Sent By rmcdouga Date 2002-08-23 Time 11:36 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-23 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - ARCHED TOP FIXED GLASS WINDOWS.
  
 2) PROVIDE (2) COPIES OF MANFACTURER'S
 SPECIFICATIONS AND UL LISTING NUMBER FOR
 A ONE HOUR FIRE RATED GLASS BLOCK
 ASSEMBLY.
  
 3) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS. A SEPARATE
 PERMIT WITH ADDITIONAL FEES WILL BE
 REQUIRED.
  
 4) PLEASE REVISE THE PLANS FOR FUTURE
 SUBMITTALS TO INCLUDE THE FOLLOWING
 INFORMATION:
 - INDICATE THE APPROPRIATE INTERNAL
 PRESSURE COEFFICENT.(+ OR - .18 FOR
 ENCLOSED STRUCTURES)
 - SPECIFY THE FIREBLOCKING MATERIAL THAT
 WILL BE USED AT THE TOP AND BOTTOM OF
 THE STAIR RUN.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-08-05 Cont ID  
Sent By btrobaug Date 2002-07-03 Time 16:28 Rev Time 0.00
Received By jgomez Date 2002-08-01 Time 15:46 Sent To  
Notes
2002-08-01 00:00:00CHECKLIST:
 1-PROVIDE SOIL TEST REPORT SIGNED AND
 SEALED BY ENGINEER.
 2-PROVIDE UPDATED/CORRECTED SURVEY.
 3-PROVIDE DETAIL/SPECS FOR CEILING INS-
 TALLATION AT ENTRY AND REAR PORCHES.
 SEE ASTM C-1063 FOR MINIMUM FASTENERS
 TO BE USED.
 4-PROVIDE ATTIC ACCESS AT MASTER BEDROOM
 WING AND AT 2ND FLOOR. SEC 2309.6 FBC
 5-CLARIFY SIZE OF EGRESS WINDOWS AT 2ND
 FLOOR. SH24 AND SH34 ARE TYP. 48" HIGH
 AND THEY WILL NOT PROVIDE THE MIN. 24"
 CLEAR HEIGHT REQUIRED BY SEC. 1005.4.4
 FBC 2001. ALSO, NEED 5.7SF MIN. CLEAR
 OPENING (SH24 DOESN'T MAKE IT). ARE
 THEY CUSTOM MADE WINDOWS FOR EGRESS?
 6-SPECIFY FIREBLOCKING MATERIAL AND
 LOCATION AT STAIRS. SEC. 2305.1 FBC
 7-SPECIFY DRAFSTOPPING LOCATION AND
 MATERIAL AT 2ND FLOOR FRAMING PLAN.
 SEC. 2305.2.2 FBC 2001.
 8-PROVIDE 2X STRUCTURAL JAMB BUCK DETAIL
 FOR SLIDING GLASS DOORS. SEE PRODUCT
 APPROVAL AND PLANS-SHEET A-1.
 9-SPECIFY CEILING FAN SIZE AND LOCATION
 (SEE ELEC. PLAN). THEY SHALL BE IN
 PLACE FOR INSPECTION IF CREDIT FOR
 THEM IS TAKEN IN THE ENERGY CALCS.
 SEE TABLE 6-6 CHAPTER 13 FBC FOR SIZES
 10-LEFT ELEVATION DOESN'T MATCH FLOOR
 PLAN. REVISE AS REAUIRED.
 11-PROVIDE DETAILS/SPECS FOR ALL TOP
 CONNECTIONS OF STEEL AND WOOD COLS.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC
 12-REVISE DETAIL D/S-2. IT'S A WOOD COL.
 NOT STEEL.
 13-SPECIFY UPLIFT CONNECTOR FOR ROOF
 TRUSSES RESTING ON 2X LEDGER AT REAR
 PORCH AREA. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 14-STORM SHUTTERS INFORMATION IS MISSING
 KEY PLAN & COMPLETE INSTALLATION SCHED
 SUBMIT COMPLETE INFORMATION UNDER A
 SEPARATE PERMIT.
 15-PROVIDE PRODUCT APPROVAL FOR:
 A)FIXED WINDOWS WITH ARCHED TOP AS SHOWN
 ON ARCHITECTURAL PLANS.
 B)GLASS BLOCK WITH SPECS FOR ONE HOUR
 FIRE RATED ASSEMBLY REQUIRED BY TABLE
 600 FBC 2001.
 C)ENTRY DOORS WITH LEGIBLE DRAWINGS.
  
 16-ARCHITECT TO SEE PLANS FOR ADDITIONAL
 COMMENTS AND UPDATE/REVISE AS REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-20 Cont ID  
Sent By sgraham Date 2002-06-20 Time 12:30 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***