Plan Review Details - Permit 02060991
Plan Review Stops For Permit 02060991
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-26 Cont ID  
Sent By rmcdouga Date 2002-07-26 Time 16:07 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-07-26 00:00:00OK PER D.PALMER 6-28-02

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-27 Cont ID  
Sent By hmoser Date 2002-06-27 Time 17:15 Rev Time 0.50
Received By hmoser Date 2002-06-27 Time 17:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-22 Cont ID  
Sent By jleech Date 2002-06-22 Time 06:19 Rev Time 0.33
Received By jleech Date 2002-06-22 Time 06:18 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-20 Cont ID  
Sent By rmcdouga Date 2002-08-20 Time 09:07 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-20 00:00:00************BUILDING PROVISO************
  
 1) SUBMIT DETAILED DRAWING OF ONE HOUR
 RATED ASSEMBLY FOR THE GABLE END ABOVE
 THE GARAGE LOCATED ON THE ZERO LOT LINE.
 DRAWING MUST BE SIGNED AND SEALED BY THE
 DESIGNER OF RECORD.
  
 2) SUBMIT A DETAILED DRAWING OF THE
 STEEL PLACEMENT FOR THE CANTILEVERED
 BEAMS AT THE COVERED REAR PORCH.
 INDICATE THE DISTANCE THE STEEL AND
 HOOPS ARE TO EXTEND BACK INTO THE 8 X 12
 TIEBEAM ABOVE THE MASONRY WALLS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-07-29 Cont ID  
Sent By rmcdouga Date 2002-07-29 Time 14:17 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-07-29 00:00:00BUILDING DENIED
  
 1)FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
 PLEASE INDICATE ON PLANS.
  
 2)2305.2.2 FLOOR/CEILING ASSEMBLIES
 SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL/
 ING ASSEMBLIES SEPERATING USEABLE SPACE
 INTO 2 OR MORE APPROXIMATE AREAS WITH NO
 AREA GREATER THAN 500 SQ FT. DRAFTSTOP-
 PING SHALL BE PROVIDED PARALLEL TO THE
 MAIN FRAMING MEMBERS. PLEASE INDICATE
 ON THE PLANS.
  
 3) THE ENERGY CALCULATIONS LISTS FOUR
 BEDROOMS AND THE PLANS INDICATE THREE
 BEDROOMS. PLEASE CORRECT.
  
 4) EXTERIOR WALLS AND THE GABLE ENDS OF
 ROOFS WITHIN FIVE FEET OF PROPERTY LINES
 MUST BE DESIGNED FOR FIRE RESISTANCE
 BASED UPON BOTH INTERIOR AND EXTERIOR
 FIRE EXPOSURE. 2001 FBC TABLE 600
 INDICATE HOW THE ONE HOUR RATING WILL BE
 ACHIEVED AT THE GABLE WALL ON THE ZERO
 LOT LINE.
  
 5) PROVIDE CLARIFICATION AT CANTILEVER
 BEAMS. THE PLANS DO NOT INDICATE WHERE
 THE WALL ON THE RIGHT SIDE ENDS AND THE
 CANT. BEAM BEGINS. THE FOUNDATION, WALL
 AND VERTICAL REINFORCEMENT ON SHEETS
 1,2,& 3B FOR THE RIGHT WALL AT THE
 COVERED PORCH DOES NOT MATCH ELEVATIONS.
 PLEASE CORRECT.
  
 6) THE POSITIVE WINDLOAD PRESSURE LISTED
 FOR THE GARAGE DOOR (+39.8 PSF) EXCEEDS
 THE POSTIVE DESIGN PRESSURE (+ 37 PSF)
 FOR THE OVERHEAD GARAGE DOOR. PLEASE
 SUBMIT AN APPROPRIATE PRODUCT APPROVAL.
  
 7) THE INFORMATION IN THE WIND PRESSURE
 SCHEDULE FOR THE WINDOWS AND DOORS
 CONTAINS INCORRECT INFORMATION. PLEASE
 CORRECT.
  
 8) THE STORM PANEL SCHEDULE AND KEY PLAN
 DIFFERS FROM THE PLANS AT THE SECOND
 FLOOR WINDOWS ABOVE THE LIVING/DINING
 AREA.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-20 Cont ID  
Sent By jwitmer Date 2002-06-18 Time 16:34 Rev Time 0.25
Received By sgraham Date 2002-06-18 Time 16:35 Sent To Z
Notes
***NONE***