Plan Review Stops For Permit 02060778 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-02-03 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-02-03 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-02-03 |
Time |
12:11 |
Sent To |
|
|
Notes |
2003-02-03 00:00:00 | REVISION DATED 1/27/03 REF A-1. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-09-05 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-09-05 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2002-09-05 |
Time |
14:34 |
Sent To |
|
|
Notes |
2002-09-05 00:00:00 | ARCHITECTS REVISION DATE 8/26/02 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-07-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-07-15 |
Time |
14:09 |
Rev Time |
1.75 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-07-15 00:00:00 | | | | | BUILDING PLAN REVIEW | | PERMIT: 02060778 | | ADD: 250 AUSTRALIAN AVE / 1504 | | CONT: BURKHARDT CONSTRUCTION | | TEL: 659-1400 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | ITIONS, EXIT ENCLOSURES, AND FIRE | | RATED WALLS REQUIRED TO HAVE PROTECTED | | OPENINGS SHALL BE EFFECTIVELY AND | | PERMANETLY IDENTIFIED WITH SIGNS OR | | STENCILING IN A MANNER ACCEPTABLE TO THE | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | CEILING CEILING AND IN CONCEALED SPACES. | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | PROTECT ALL OPENINGS". | | | | 2) SHEET A-1 NOTE, MAILROOM # 26 | | NEW LOCKING HDWR,TO COMPLY 1020.3(1) | | "THIS EXIT TO REMAIN UNLOCKED WHEN THIS | | BUILDING IS OCCUPIED". | | | | 3) SHEET A-2 DOOR SCHEDULE NOTE# 2, | | PROVIDE SOLENOID ACTIVATED LATCH, PUSH | | BOTTON TO BE LOCATED AT RECEPTION DESK? | | ADDITONAL INFO. | | | | 4) TABLE 803.3 MINIMUM INTERIOR FINISH | | CLASSIFICATION; PROVIDE INFORMATION | | BASED ON INTERIOR FINISH REQUIREMENTS | | BASED ON OCCUPANCY | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | ON THE APPLICATION, PLANS, OR ATTACHED | | SEPARATELY. WHEN RESUBMITTING PLANS | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | DESCRIPTION OF THE REVISION MADE, IDEN- | | TIFYING THE SHEET OR SPECIFICATION PAGE | | WHERE THE CHANGES CAN BE FOUND, WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | FOR YOUR ANTICIPATED COOPERATION. | | JIM WITMER | | PLAN REVIEW | | TEL: (561)659-8096 EX.8412 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-02-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-02-04 |
Time |
14:10 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-02-04 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-06-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-06-27 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-06-27 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-08-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-08-29 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-08-29 |
Time |
15:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-07-16 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-07-16 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-07-16 |
Time |
12:31 |
Sent To |
|
|
Notes |
2002-07-16 00:00:00 | 1) DOOR SCHEDULE INDICATES THAT A | | SOLENOID WILL BE CONNECTED TO THE | | DOOR LATCH. ONLY DELAYED EGRESS OR | | ACCESS CONTROLLED EGRESS WILL BE | | ALLOWED ON REQUIRED EXIT DOORS. PLEASE | | SEE NFPA 101, 2000 EDITION, CHAPTER 7. | | | | 2) EXIT DOOR LOCKS SHALL NOT REQUIRE | | THE USE OF ANY KEYS, TOOLS, OR | | SPECIAL KNOWLEDGE TO OPERATE. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-01-30 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2003-01-30 |
Time |
14:46 |
Sent To |
|
|
Notes |
2003-01-30 00:00:00 | COM BOARD #2./WRT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-02-07 |
Time |
13:51 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-02-07 |
Time |
13:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-06-22 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-06-22 |
Time |
10:54 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2002-06-22 |
Time |
10:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-02-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-02-05 |
Time |
16:00 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2003-02-05 |
Time |
16:00 |
Sent To |
|
|
Notes |
2003-02-05 00:00:00 | REVISION OK - DELETE NEW SINK - ADD | | WATER LINE TO COFFEE MAKER - ICE MAKER | | PROVISO: WATER HAMMER ARRESTOR REQUIRED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-09-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-09-05 |
Time |
18:36 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-09-05 |
Time |
18:36 |
Sent To |
|
|
Notes |
2002-09-05 00:00:00 | PASSED/PROVISO | | | | FIELD INSPECTOR SHALL VERIFY NSF APPRO- | | VAL FOR FILTER AND LISTING FOR INSTA-HOT |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2002-06-28 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-06-28 |
Time |
18:09 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-06-28 |
Time |
18:09 |
Sent To |
|
|
Notes |
2002-06-28 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FBC-2001 PLUMBING | | | | 1) A DRINKING FOUNTAIN AND SERVICE SINK | | ARE REQUIRED PER TABLE 403.1. PLEASE IN- | | DICATE IF THESE ARE PROVIDED. | | 2) SHT A-1 PROVIDE MANUFACTURE INFORMAT- | | ION FOR INSTA HOT AND WATER FILTER UNDER | | KITCHEN SINK. INSTA HOT MUST SHOW LIST- | | ING FROM AN APPROVED TESTING AGENCY, AND | | THE WATER FILTER MUST BE NSF APPROVED. | | 3) SHT P-1 WATER RISER DIAGRAM. SHOW | | WATER HAMMER ARRESTOR NEAR FIXTURE IN | | AN "EFFICTIVE RANGE" NOT AT TOP OF DROP | | AS SHOWN. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|