Plan Review Details - Permit 02060673
Plan Review Stops For Permit 02060673
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-07-22 Cont ID  
Sent By jwitmer Date 2002-07-22 Time 11:56 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-07-01 Cont ID  
Sent By dpalmer Date 2002-07-01 Time 07:02 Rev Time 0.00
Received By dpalmer Date 2002-07-01 Time 07:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-06-28 Cont ID  
Sent By mcarsill Date 2002-06-28 Time 11:29 Rev Time 0.00
Received By mcarsill Date 2002-06-28 Time 11:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-25 Cont ID  
Sent By pkrauss Date 2002-06-25 Time 13:23 Rev Time 0.40
Received By pkrauss Date 2002-06-25 Time 13:22 Sent To  
Notes
2002-06-25 00:00:00PROVISO:MECHANICAL PERMIT 02060852
 UNIT - BR
  
 2001 FBC(M) 402.2 - NATURAL VENTILATION
 FOR OUTSIDE AIR REQUIRMENT. SHOW
 COMPLIANCE FOR THE MINIMUM OPENABLE AREA
 TO THE OUTDOORS. (4 PERCENT OF THE FLOOR
 AREA BEING VENTILATED) OR TABLE 403.3
 FOR MECHANICAL VENTILATION.
  
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 APPLIANCES SHALL NOT BE INSTALLED IN A
 LOCATION WHERE SUBJECT TO MECHANICAL
 DAMAGE UNLESS PROTECTED BY APPROVED
 BARRIERS.2001 FBC(M) 303.4
  
 OVERFLOW PROTECTION REQUIRED AS PER
 2001 FBC(M) 307.2.3.
  
 THE MAXIMUM DEVELOPED LENGTH FOR THE
 DRYER VENT SHALL NOT EXCEED 25 FT WITH
 A 5 FT REDUCTION FOR EACH 90 DEGREE
 BEND & A 2 1/2 REDUCTION FOR EACH 45
 DEGREE BEND.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-22 Cont ID  
Sent By jleech Date 2002-06-22 Time 08:03 Rev Time 0.00
Received By jleech Date 2002-06-22 Time 08:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-07-22 Cont ID  
Sent By jwitmer Date 2002-07-22 Time 12:08 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-07-22 00:00:00OK PER DR 6/20/02


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved