Plan Review Details - Permit 02060268
Plan Review Stops For Permit 02060268
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-08-05 Cont ID  
Sent By jwitmer Date 2003-08-05 Time 07:59 Rev Time 0.13
Received By jwitmer Date 2003-08-05 Time 07:58 Sent To  
Notes
2003-08-05 00:00:00PRODUCT APPROVAL " DADE COUNTY"
 SERIES "8000" MULTI-TRACK CORNER, POCKET
 AND BY-PASS SLIDING GLASS DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-06-27 Cont ID  
Sent By alange Date 2003-07-31 Time 13:59 Rev Time 0.33
Received By jwitmer Date 2003-06-27 Time 07:00 Sent To  
Notes
2003-06-27 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02060268 LOT 7 EAGLE ISLE
 02101337 LOT 10 BAY POINTE
 03020682 LOT 19 BAY POINTE
 03011211 LOT 22 BAY POINTE
 02061029 LOT 31 BAYPOINTE
 CONT: AR CUSTOM HOMES
 TEL: (561)718-4176
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 RE: SITE SPECIFIC APPROVALS/
 PEER REVIEW
  
 ACTION: DENIED
  
 1)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD. AS SET FORTH BY BUILDING OFFI
 CIAL NEIL MELICK IN " IMPLEMENTATION
 STANDARD FOR HURRICANE MISSLE IMPACT
 PROTECTION, SECTIONS 103.6, 1606.4,
 1707.4 AND 3401.2.4.
  
 ALL DOCUMENTATION SUBMITTED FOR EACH
 PERMIT HAS TO BE A "STAND ALONE PERMIT",
 SO AT EVERY SITE, SITE SPECIFIC OR "PEER
 REVIEW" HAS TO HAVE SEALED ENGINEERING
 DOCUMENTS,THE DOCUMENT FROM SCHAEFER,PE,
 THIS DOCUMENT HAS TO HAVE THE LOTS OR
 ADDRESSES LISTED! SITE SPECIFIC!!
  
 THE OTHER ISSUE IS THE TEST REPORT FROM
 CERTIFIED TESTING LABS ALSO A DOCUMENT
 FROM A ENGINEER FOR PUBLIC RECORD,
 REQUIRES SINED AND SEALED DRAWINGS, NOT
 A COPY OF SIGNATURE NOR OF SEAL!
  
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 IF THE SUPPORTING DOCUMENTS SUBMITTED
 FOLLOW GETTING THE PROPER SITE SPECIFIC
 INFORMATION AND ORIGINAL SIGNATURE AND
 SEALED DOCUMENTATION THE CITY WILL
 ACCEPT THESE DOCUMENTS IF THE ABOVE
 STATED GUIDELINES ARE FOLLOWED. THE CITY
 WILL ACCEPT (1) COMPLETE SIGNED & SEALED
 DOCUMENT (PER PERMIT) FOR THE OFFICIAL
 FILE DOCUMENT, THE JOBSITE COPY MAY BE
 A PHOTO COPY, PLEASE SHADE THE SEAL
 BEFORE REPRODUCING.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)805-6715

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-12-30 Cont ID  
Sent By jwitmer Date 2002-12-30 Time 15:54 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-12-30 00:00:00REVISION: ROOFING RAINPROOF 40-
 RAINPROOF 60OK

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-21 Cont ID  
Sent By dpalmer Date 2002-08-21 Time 18:22 Rev Time 0.75
Received By dpalmer Date 2002-08-21 Time 18:22 Sent To  
Notes
2002-08-21 00:00:00************* NOTE/PROVISO/REVISION****
  
 1)NOTE: PLEASE NOTE SERVICE ENTRANCE
 CONDUCTORS SHOWN AS 3-#10`S. PLEASE SEE
 310-15/ 310-16 FOR CORRECT SIZING.
  
 PLEASE REVISE RISER DIAGRAM AND ANY
 OTHER CHANGES ON PLANS BEFORE FINAL.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-06-18 Cont ID  
Sent By dpalmer Date 2002-06-19 Time 05:38 Rev Time 0.00
Received By dpalmer Date 2002-06-18 Time 19:56 Sent To B
Notes
2002-06-18 00:00:00**************** UNSAT *****************
  
 1)NOTE: PLEASE NOTE THAT RISER DIAGRAM,
 PANEL SCHEDULE,LOAD CALCULATIONS, DO NOT
 CORRELATE. 180A , 200A, 300A??? SHOWN IN
 DIFFERENT LOCATIONS??
  
 2)NOTE: PLEASE NOTE THAT THERE ARE FOUR
 SMALL APPL CIRCUITS SHOWN IN LOAD CALCS
 AND ONLY TWO ON PANEL SCHEDULE?
  
 3)NOTE: PLEASE NOTE LOAD FOR AHU HEAT IS
 SHOWN AT 10KW AND HAS AN OCP OF 50A?
 PLEASE SEE SIZING OF OCP PER 424-3-B
  
 4)NOTE: PLEASE NOTE LAYOUT FOR HOUSE
 DOES NOT CORRELATE WITH MECH PLAN?
 WHICH ONE? PLEASE SHOW COND UNITS AND
 AHU`S ON ELECTRICAL PLAN WITH REQ`D DISC
 `S PER 440-11.
  
 5)NOTE: PLEASE NOTE DEPENDING ON WHAT
 SIZE OF OCP IS FINALLY SHOWN , PLEASE
 SIZE SERVICE ENTRANCE CONDUCTORS. PLEASE
 ALSO NOTE/CLARIFY (4) CONDUCTORS FROM
 METER TO PANEL FOR SINGLE PHASE SERVICE.
 PLEASE CLARIFY.
  
 6)NOTE: PLEASE SHOW AND SIZE GROUNDING
 ELECTRODE CONDUCTOR PER 250-66.
  
 7)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 8) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 MISSING ONLY A COUPLE.
  
 9)NOTE: PLEASE NOTE MISSING SD OUTSIDE
 BR#2.
  
 10)NOTE:PLEASE CLARIFY IF A 42 CIRCUIT
 PANEL IS 200A OR 225A??
  
 11)NOTE: PLEASE NOTE MIN KVA FOR LAUNDRY
 CIRCUIT SHALL BE 1500W. PLEASE REVISE
  
 12)NOTE: PLEASE NOTE POOL EQUIPMENT IS
 SHOWN AT 4500W AND SHOWN ON PANEL SCHED-
 -ULE AS 20A AND #12AWG?? PLEASE CLARIFY.
  
 13)NOTE: PLEASE NOTE, NOTE BELOW PANEL
 SCH, MENTIONS, USE "TW" FOR LARGER THAN
 #8?? PLEASE SEE NEC IN MANY LOCATIONS
 FOR USE OF "TW" PLEASE ALSO NOTE SIZING
 OF CONDUCTORS PER 60 DEGREE RATINGS PER
 310-16. MOST OF WIRING USED TODAY IS
 NOT TW.
  
 14)NOTE: PLEASE CLARIFY SQ FT OF HOUSE,
 LOAD CALCS SHOW 6775 AND COVER SHEET
 SHOWS 6034?
  
 15)NOTE: PLEASE NOTE ELECTRICAL PLAN
 SHOWN FOR SECOND FLOOR IS NOT CLEAR WITH
 ALL BLDG SPECS PRINTED OVER. PLEASE ALSO
 NOTE PRINTING SEEMS TO HAVE MISSED PART.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE NAY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-31 Cont ID  
Sent By alange Date 2003-07-31 Time 13:59 Rev Time 0.00
Received By alange Date 2003-07-31 Time 13:59 Sent To B
Notes
2003-07-31 00:00:00TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 12:04 Rev Time 0.00
Received By dpalmer Date 2002-12-19 Time 12:04 Sent To B
Notes
2002-12-19 00:00:00SUBMITTAL TO JIM WITMER

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-17 Cont ID  
Sent By hmoser Date 2002-06-17 Time 19:48 Rev Time 0.50
Received By hmoser Date 2002-06-17 Time 19:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-08-28 Cont ID  
Sent By kstevens Date 2002-08-28 Time 12:59 Rev Time 0.00
Received By kstevens Date 2002-08-28 Time 12:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-13 Cont ID  
Sent By jleech Date 2002-06-13 Time 18:24 Rev Time 0.50
Received By jleech Date 2002-06-13 Time 18:24 Sent To  
Notes
2002-06-13 00:00:00DENIED;
 PAGE 4-C PLUMBING RISER.
 1.BIDET NOT VENTED.
 2.SECOND FLOOR KITCHEN SINK BRANCH IS
 NOT TO CODE AS DRAWN.
 3.DRAINS IN UTILITY ROOM AND ICE MAKER,
 ARE THEY FLOOR DRAINS? IF SO WHAT SIZE
 AND MUST HAVE TRAP PRIMERS OR BE DEEP
 SEAL TRAPS.
 4SIZE ALL VENTS
 5.TOTAL FIXTURE COUNT IS 38.5FUS, IF 3"
 SEWER IS RUN A NOT IS REQUIRED, SLOPE
 MUST BE 1/4' PER FOOT.
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-09-03 Cont ID  
Sent By jwitmer Date 2002-09-03 Time 12:58 Rev Time 2.25
Received By jwitmer Date 2002-09-03 Time 11:39 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-07-02 Cont ID  
Sent By jwitmer Date 2002-07-02 Time 15:07 Rev Time 2.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-07-02 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02060268
 ADD: 7113 EAGLE TERRACE
 CONT: A R CUSTOM HOMES INC
 TEL: (561)721-2270
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)-2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR. SECOND FLOOR BONUS ROOM
 REQUIRES AN EMERGENCY EGRESS WINDOW.
 THE CASEMENT WINDOW DOESN'T MAKE THE 20"
 CLEAR HORIZONTAL MEASUREMENT. SEE PAGE
 11 OF 12 PRODUCT APPROVAL FOR DIMINSION
 OF EXTRUDED FRAME. THE SECOND FLOOR
 ELEMENT SHALL ALSO REQUIRE A CLEAR OPEN-
 ING OF 5.7 SQ FT.
  
 2) PROVIDE ENGINEERING FOR BUTT GLASS
 ASSEMBLIES PER 2001 FBC 2406.2. SHEET 5B
 INDICATES UNDER"WIND PRESSURE ANALYSIS"
 BUTT GLASS SEE SHEET S-2 FOR RATIONAL
 ANALYSIS. MISSING STRUCTURAL SHEETS!!!
 A) LIVING ROOM
 B) MORNING ROOM
 C) MASTER BATH SHOWER
  
 3) DISCREPANCIES, SHEET A-5 INDICATES
 THE USE OF BUTT GLAZING IN THE LIVING
 ROOM AND MORNING ROOM A HEIGTH OF 144"'
 WHILE SHEET A-6 INDICATES THE USE OF A
 HORIZONTAL MULLION @ 10'-0" FOR BOTH
 CASES?
  
 4)2305.2.2 FLOOR/CEILING ASSEMBLIES
 SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL/
 ING ASSEMBLIES SEPERATING USEABLE SPACE
 INTO 2 OR MORE APPROXIMATE AREAS WITH NO
 AREA GREATER THAN 500 SQ FT. DRAFTSTOP-
 PING SHALL BE PROVIDED PARALLEL TO THE
 MAIN FRAMING MEMBERS.
  
 5) SHEET A-5A BONUS RM # 2 MISSING SMOKE
 DETECTOR IN ROOM.
  
 6)- FL BL CODE 905.2.1 SMOKE DETECTORS,
 WHERE MORE THAN 1 SMOKE DETECTOR IS
 REQUIRED TO BE INSTALLED WITHIN DWELLING
 UNITS, THE DETECTORS SHALL BE WIRED IN
 SUCH A MANNER THAT THE ACTIVATION OF ONE
 ALARM WILL ACTIVATE ALL THE ALARMS IN
 THE INDIVIDUAL UNIT.
  
 7) FL ENERGY CODE MISSING INSULATION
 UNDER THE 2ND STORY FLOOR, ALSO NOT INCL
 UDED ON ENERGY SHEET.
  
 8) SHEET 6-C TRUSS LAYOUT MISSING THE
 MAGNITUDE OF LOADS TO BE RESISTED,
 VERTICAL, HORIZONTAL & LATERAL.
  
 9) 2806.1.2 FACTORY BUILT FIREPLACES
 SHALL BE TESTED IN ACCORDANCE WITH AND
 MEET THE REQUIREMENTS OF UL 127. PROVIDE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-07 Cont ID  
Sent By sgraham Date 2002-06-07 Time 14:16 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***