Plan Review Details - Permit 02051645
Plan Review Stops For Permit 02051645
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-08 Cont ID  
Sent By dpalmer Date 2002-08-08 Time 06:43 Rev Time 0.00
Received By dpalmer Date 2002-08-08 Time 06:43 Sent To  
Notes
2002-08-08 00:00:00******** NOTE******
  
 STILL REDLINED.
 OCP/WIRE/BRKRS NEED TO CORRELATE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-12 Cont ID  
Sent By pkrauss Date 2002-06-12 Time 15:59 Rev Time 0.00
Received By dpalmer Date 2002-06-12 Time 19:25 Sent To B
Notes
2002-06-12 00:00:00REDLINED ON PLANS FOR OCP/WIRE FOR AHU`S

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-01 Cont ID  
Sent By btrobaug Date 2002-11-01 Time 14:12 Rev Time 0.00
Received By btrobaug Date 2002-11-01 Time 14:12 Sent To R
Notes
2002-11-01 00:00:00TO JULIO./WRT

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-11 Cont ID  
Sent By rregueir Date 2002-12-11 Time 18:19 Rev Time 0.50
Received By rregueir Date 2002-12-11 Time 18:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-09 Cont ID  
Sent By pkrauss Date 2002-08-09 Time 13:55 Rev Time 0.20
Received By pkrauss Date 2002-08-09 Time 13:55 Sent To  
Notes
2002-08-09 00:00:00RESTAMP
 MECH PERMIT 02051674

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-12 Cont ID  
Sent By pkrauss Date 2002-06-12 Time 15:58 Rev Time 0.40
Received By pkrauss Date 2002-06-12 Time 15:57 Sent To E
Notes
2002-06-12 00:00:00PROVISO:MECHANICAL PERMIT 02051674
  
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS
 WITH NOTIFICATION TO ALARM/STOBE OR AREA
 SMOKE DETECTORS. 2001 FBC(M) 606.4.1
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-08 Cont ID  
Sent By jleech Date 2002-06-08 Time 09:16 Rev Time 0.33
Received By jleech Date 2002-06-08 Time 09:16 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2003-01-27 Cont ID  
Sent By jgomez Date 2003-01-27 Time 10:40 Rev Time 1.50
Received By jgomez Date 2003-01-27 Time 10:40 Sent To  
Notes
2003-01-27 00:00:00CHECKLIST FOR PROVISO SUBMITTAL:
 1-ENGINEERING CALCULATIONS SHOW THAT
 WOOD COLUMNS (P1) ARE NOT STRUCTURALLY
 ADEQUATE. SHEET S-1 SHOWS WOOD COLUMN
 P1 AT DEN AREA. CLARIFY AND REVISE AS
 REQUIRED AND PROVIDE CERTIFICATION
 THAT STEEL COLUMN WAS INSTALLED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 2-PROVIDE SOIL TEST REPORT. THERE'S NONE
 SUBMITTED FOR THE CITY FILES.
 3-STORM SHUTTERS: A)PROVIDE COMPLETE
 SBCCI PRODUCT APPROVAL REPORT #2229.
 B)CLEARLY MARK ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
 C)CHECK DESIGN PRESSURES SPECIFIED ON
 PLANS AND THOSE SPECIFIED ON INSTALLA-
 TION SCHEDULE.
 D)PROVIDE INSTALLATION SCHEDULE AND KEY
 PLAN THAT MATCH ACTUAL PLANS SUBMITTED
  
 4-SINGLE HUNG WINDOWS PRODUCT APPROVAL
 IS EXPIRED.
 5-ENTRY DOOR PRODUCT APPROVAL NEED FRONT
 PAGE TO HAVE DADE COUNTY LOGO AND THE
 DRAWINGS STAMPED WITH THE RENEWAL # AS
 REQUIRED BY DADE COUNTY.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-06 Cont ID  
Sent By btrobaug Date 2002-11-01 Time 14:12 Rev Time 0.00
Received By jgomez Date 2002-08-06 Time 15:07 Sent To  
Notes
2002-08-06 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE SOIL TEST REPORT SIGNED AND
 SEALED BY THE ENGINEER.
 2-STORM SHUTTERS:
 A)DRAWINGS DON'T MATCH PRODUCT APPROVAL.
 B)DRAWINGS ARE NOT LEGIBLE.
 C)VERIFY IF OPENINGS ARE THE SAME AS
 SHOWN ON THE SUBMITTED PLANS.
 3-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS PRODUCT APPROVAL & DWGS
 ARE NOT LEGIBLE (NOTE: BE AWARE THAT
 THIS PRODUCT WILL EXPIRE 8-31-02. KEEP
 IN MIND FOR FUTURE SUBMITTALS.
 B)SINGLE HUNG WINDOWS PRODUCT APPROVAL
 REPORT FIRST PAGE DOESN'T MATCH THE
 REST OF THE REPORT AND DRAWINGS.
 RESUB. CORRECT REPORT AND DRAWINGS.
 4-SPECIFY FIREBLOCKING MATERIAL AND
 LOCATION AT STAIRS (MISSING SIZE AND
 THER IS NOT FIREBLOCKING SHOWN ON TOP
 OF STAIRS. SEE SEC. 2305.1.4 FBC 2001.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-06-21 Cont ID  
Sent By jgomez Date 2002-06-21 Time 17:57 Rev Time 3.50
Received By jgomez Date 2002-06-21 Time 17:57 Sent To  
Notes
2002-06-21 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-DIRECT ENTRY FROM GARAGE TO BONUS BED-
 ROOM IS NOT ALLOWED BY SEC. 411.2.8
 FBC 2001.
 3-24SH WINDOW SIZE TYP. DON'T PROVIDE
 THE MIN 24" CLEAR HEIGHT & 5.7 S.F.
 CLEAR OPENING REQ'D BY SEC. 1005.4.4
 FBC 2001. IS THIS CUSTOM MADE WINDOW?
 4-REVISE A/C AREA IN ENERGY CALCULATIONS
 TO MATCH ARCHITECTURAL PLANS.
 5-SPECIFY FIRECUTS AT MASONRY WALL AS
 REQ'D BY SEC. 2305.4 FBC 2001.
 6-PROVIDE SPECS TO PROTECT SOIL & FOOT'G
 FROM WATER FALLING FROM ROOF VALLEYS.
 SEC. 1804.1.6 FBC 2001.
 7-PROVIDE SOIL TEST REPORT.
 8-PROVIDE DESIGN OF JOINTS @ CONC. SLAB.
 SEC. 1909.3 FBC 2001 (OR SPECIFY WWM
 SUPPORTS. SEE EXCEPTION ON SEC. 1909.3
 9-STORM SHUTTERS:
 A)PROVIDE COMPLETE INSTALLATION SCHEDULE
 AND KEY PLAN. SEE ATTACHED CITY SAMPLE
 B)CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS & ANCHOR TYPE AND
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
 10-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS AS SHOWN ON PLANS.
 B)COMPLETE DADE COUNTY PRODUCT APPROVAL
 FOR "PAN AMERICAN" WINDOW MULLIONS
 SINCE WINDOWS ARE FROM PAN AMERICAN.
 11-PROVIDE UPDATED ORIGINAL LETTER FOR
 MASONRY TO BE USED. LETTER ADDRESSED
 TO CITY OF WPB. IDENTIFY PROJECT AND
 CONTRACTOR.
 12-SPECIFY FIREBLOCKING MATERIAL AND
 LOCATION AT STAIRS. SEC. 2305.1.4 FBC.
 13-SPECIFY DRAFSTOPPING MATERIAL AND
 LOCATION @ 2ND FL FRAMING PLAN AS
 REQ'D BY SEC. 2305.2.2 FBC 2001.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-31 Cont ID  
Sent By sgraham Date 2002-05-31 Time 14:55 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***