Plan Review Details - Permit 02051643
Plan Review Stops For Permit 02051643
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-08 Cont ID  
Sent By dpalmer Date 2002-08-08 Time 06:15 Rev Time 0.00
Received By dpalmer Date 2002-08-08 Time 06:15 Sent To P
Notes
2002-08-08 00:00:00*****
  
 ADDRESSED REDLINED FROM FIRST REVIEW.
 RESTAMPED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-12 Cont ID  
Sent By pkrauss Date 2002-06-12 Time 15:56 Rev Time 0.00
Received By dpalmer Date 2002-06-12 Time 19:34 Sent To B
Notes
2002-06-12 00:00:00REDLINED PLANS FOR OCP/WIRE FOR AHU`S

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-01 Cont ID  
Sent By btrobaug Date 2002-11-01 Time 14:11 Rev Time 0.00
Received By btrobaug Date 2002-11-01 Time 14:10 Sent To R
Notes
2002-11-01 00:00:00TO JULIO./WRT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-09 Cont ID  
Sent By pkrauss Date 2002-08-09 Time 13:48 Rev Time 0.20
Received By pkrauss Date 2002-08-09 Time 13:46 Sent To  
Notes
2002-08-09 00:00:00RESTAMP MECH PERMIT 02051685

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-12 Cont ID  
Sent By pkrauss Date 2002-06-12 Time 15:04 Rev Time 0.40
Received By pkrauss Date 2002-06-12 Time 14:51 Sent To E
Notes
2002-06-12 00:00:00MECHANICAL PERMIT 02051685
  
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS
 WITH NOTIFICATION TO ALARM/STOBE OR AREA
 SMOKE DETECTORS. 2001 FBC(M) 606.4.1
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-08 Cont ID  
Sent By dpalmer Date 2002-08-08 Time 06:28 Rev Time 0.33
Received By jleech Date 2002-06-08 Time 09:18 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-05 Cont ID  
Sent By btrobaug Date 2002-11-01 Time 14:11 Rev Time 0.00
Received By jgomez Date 2002-08-05 Time 18:18 Sent To  
Notes
2002-08-05 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE SOIL TEST REPORT SIGNED AND
 SEALED BY THE ENGINEER.
 2-STORM SHUTTERS:
 A)DRAWINGS DON'T MATCH PRODUCT APPROVAL.
 B)DRAWINGS ARE NOT LEGIBLE.
 C)REVISE INSTALLATION SCHEDULE AND KEY
 PLAN TO MATCH ACTUAL PLANS SUBMITTED
 FOR PERMIT. VERIFY SIZES, ETC.
  
 3-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS PRODUCT APPROVAL & DWGS
 ARE NOT LEGIBLE (NOTE: BE AWARE THAT
 THIS PRODUCT WILL EXPIRE 8-31-02. KEEP
 IN MIND FOR FUTURE SUBMITTALS).
 B)GARAGE SIDE SWING DOOR, WHEN HAVING
 THE OPTION FOR IT OR CROSS OUT OPTION.
 C)SINGLE HUNG WINDOWS PRODUCT APPROVAL
 REPORT FIRST PAGE DOESN'T MATCH THE
 REST OF TEH REPORT AND THE DRAWINGS.
 RESUBMIT CORRECT REPORT AND DRAWINGS.
  
 4-SPECIFY FIREBLOCKING MATERIAL, SIZE
 AND LOCATION AT STAIRS. (MISSING TOP
 OF STAIRS AND FIREBLOCKING SIZE WASN'T
 SPECIFIED). SEC. 2304.1.4.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-06-20 Cont ID  
Sent By jgomez Date 2002-06-20 Time 18:51 Rev Time 3.50
Received By jgomez Date 2002-06-20 Time 18:51 Sent To  
Notes
2002-06-20 00:00:00CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
 2-CLARIFY 24SH WINDOW SPECIFIED. TYP.
 24SH WINDOW IS 37"X48". IS THIS AN
 SPECIAL ORDER?. NEED TO PROVIDE 24"MIN
 CLEAR HEIGHT OPENING & 5.7 S.F. MIN.
 CLEAR OPENING. SEC 1005.4.4 FBC 2001.
 3-REVISE ENERGY CALCULATIONS A/C AREA TO
 MATCH PLANS.
 4-SPECIFY FIRECUTS AT MASONRY WALL AS
 REQ'D BY SEC. 2305.4 FBC 2001.
 5-PROVIDE SPECIFICATIONS FOR SOIL AND
 FOOTING PROTECTION WHEN IMPACTED BY
 WATER FROM ROOF VALLEYS. SEC. 1804.1.6
 6-PROVIDE SOIL TEST REPORT.
 7-PROVIDE DESIGN OF JOINTS AT CONCRETE
 SLAB. SEC. 1909.3 FBC 2001 (OR SPECIFY
 WWM SUPPORTS. SEE EXCEPTION ON 1909.3)
 8-STORM SHUTTERS:
 A)PROVIDE COMPLETE INSTALLATION SCHEDULE
 AND KEY PLAN.
 B)CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS & ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE & STRUCTURE TO BE ATTACHED TO.
 9-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS AS SHOWN ON PLANS.
 B)COMPLETE DADE COUNTY PRODUCT APPROVAL
 FOR "PAN AMERICAN" WINDOW MULLIONS.
 USING PAN AMERICAN WINDOWS, NOT LAWSON
 C)GARAGE DOOR SIDE DOOR. SEE PLANS.
 10-PROVIDE UPDATED ORIGINAL LETTER OF
 MASONRY TO BE USED. LETTER TO BE
 ADDRESSED TO THE CITY OF W.P.B.,
 IDENTIFY SPECIFIC PROJECT & CONTRACTOR
 11-SPECIFY FIREBLOCKING MATERIAL AND
 LOCATION AT STAIRS. SEC. 2305.1.4 FBC.
 12-SPECIFY DRAFSTOPPING LOCATION AND
 MATERIAL @ 2ND FL. FRAMING PLAN AS
 REQ'D BY SEC. 2305.2.2 FBC 2001.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-31 Cont ID  
Sent By sgraham Date 2002-05-31 Time 14:56 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***