Plan Review Details - Permit 02051528
Plan Review Stops For Permit 02051528
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-10 Cont ID  
Sent By dpalmer Date 2002-06-10 Time 16:51 Rev Time 0.00
Received By dpalmer Date 2002-06-10 Time 16:51 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-20 Cont ID  
Sent By ndenmark Date 2002-08-20 Time 15:25 Rev Time 0.25
Received By ndenmark Date 2002-08-20 Time 15:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-08 Cont ID  
Sent By hmoser Date 2002-06-08 Time 11:05 Rev Time 0.50
Received By hmoser Date 2002-06-08 Time 11:05 Sent To  
Notes
2002-06-08 00:00:00PASS/PRIVISO
 1) NEED REVISED PLAN AT FINAL
 2) VARIFY TYPE OF VENTILATION USED FOR
 FRESH AIR NATURAL SECTION 402 FBC.OR
 MECHANICAL SECTION 403 FBC.
 3) NEED CALCULATIONS FOR TYPE OF
 VENTILATION USED
 4) NEED FAN SHUTDOWN FOR FINAL
 INSPECTION SECTION 606.2.1 FBC.
 5) CONDENSATE DRAIN MUST TERMINATE 12IN
 FROM BUILDING SECTION 1503.4.4
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-04 Cont ID  
Sent By jleech Date 2002-06-04 Time 18:15 Rev Time 0.33
Received By jleech Date 2002-06-04 Time 18:15 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-06-19 Cont ID  
Sent By rmcdouga Date 2002-06-19 Time 12:56 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-06-19 00:00:00************BUILDING PROVISO************
  
 1) PROVIDE (2) COPIES OF UPDATED SOIL
 REPORTS WHICH REFERENCE THE 2001 FLORIDA
 BUILDING CODE.
  
 2) THE WELDED WIRE MESH IN THE CONCRETE
 PAD IS REQUIRED TO BE SUPPORTED PER FBC
 SEC. 1909.3.
  
 3) THE WINDOW IN BATHROOM #2 WHICH IS
 WITHIN 3 FEET OF THE TUB IS REQUIRED TO
 BE SAFETY GLAZING PER FBC SEC. 2405.2(2)
  
 4) THE GLASS BLOCK IN AT THE MASTER BATH
 TUB IS REQUIRED TO HAVE A MINIMUM
 UNIFORM FACE THICKNESS OF .25".
  
 NOTE: PLEASE INDICATE THE ABOVE
 INFORMATION ON THE PLANS FOR FUTURE
 SUBMITTALS.
  
 5)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - WINDOWS (#2 & #4) ARCHED TOP FIXED
 GLASS WINDOWS
 - GLASS BLOCK
  
 NOTE: TRUSS DRAWINGS ARE NO LONGER
 REQUIRED TO BE SUBMITTED FOR PLAN REVIEW
 THEY WILL BE REQUIRED TO BE ON THE JOB
 SITE AT TRUSS INSPECTION. A SIGNED AND
 SEALED SET FOR PUBLIC RECORD IS REQUIRED

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-31 Cont ID  
Sent By sgraham Date 2002-05-31 Time 14:57 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***