Plan Review Details - Permit 02051360
Plan Review Stops For Permit 02051360
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-07-23 Cont ID  
Sent By lsmith Date 2002-07-23 Time 16:02 Rev Time 0.25
Received By lsmith Date   Time   Sent To  
Notes
2002-07-23 00:00:00CALLED ISSAC, ENGINEER.
 PROVISO:NEED DRAWING SHOWING EQUIPMENT
 PAD DETAIL & TYPE OF ANCHORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-06-21 Cont ID  
Sent By btrobaug Date 2002-06-11 Time 07:48 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-11 Cont ID  
Sent By kstevens Date 2002-06-10 Time 18:21 Rev Time 0.00
Received By btrobaug Date 2002-06-11 Time 07:40 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-07-25 Cont ID  
Sent By kstevens Date 2002-07-25 Time 11:20 Rev Time 0.00
Received By kstevens Date 2002-07-25 Time 11:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-10 Cont ID  
Sent By kstevens Date 2002-06-10 Time 18:20 Rev Time 0.00
Received By kstevens Date 2002-06-10 Time 18:20 Sent To E
Notes
2002-06-10 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92. AND NSPI-5
 3) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 4) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 5) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 6) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-24 Cont ID  
Sent By sgraham Date 2002-05-24 Time 14:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***