Plan Review Details - Permit 02051354
Plan Review Stops For Permit 02051354
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-07-03 Cont ID  
Sent By lsmith Date 2002-07-03 Time 10:56 Rev Time 1.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-06-11 Cont ID  
Sent By btrobaug Date 2002-06-10 Time 12:42 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2002-06-11 00:00:00*****************FAILED*************
  
 OWNER OF PROPERTY IS ENGLE HOMES.HOUSE
 IS NOT COMPLETED.NO C/O FOR HOUSE YET.

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2002-07-24 Cont ID  
Sent By dpalmer Date 2002-07-24 Time 09:31 Rev Time 0.00
Received By dpalmer Date 2002-07-24 Time 09:30 Sent To  
Notes
2002-07-24 00:00:00REVIEW FOR ELEC TRIC PULLED BY POOL
 CONT DUE TO NO ELEC PLANS. SEE DV PALMER
 OR BILL TROBAUGH.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-07-23 Cont ID  
Sent By dpalmer Date 2002-07-23 Time 16:42 Rev Time 0.00
Received By dpalmer Date 2002-07-23 Time 16:42 Sent To  
Notes
2002-07-23 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASE NOTE, STILL NO ELECTRICAL
 INFORMATION/WIRING DIAGRAM SUBMITTED FOR
 POOL ELEC.
 IT IS NOTED THAT A POOL HEATER IS NOT
 GOING TO BE INSTALLED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEYPALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-06-10 Cont ID  
Sent By kstevens Date 2002-06-08 Time 08:27 Rev Time 0.00
Received By btrobaug Date 2002-06-10 Time 12:32 Sent To B
Notes
2002-06-10 00:00:00UNSAT
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE AN ELECTRICAL WIRING
 SCHEMATIC FOR REVIEW,AND A LOAD
 CALCULATION IF THERE IS TO BE A POOL
 HEATER INSTALLED (ELECTRIC).
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT. 8392

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-07-20 Cont ID  
Sent By kstevens Date 2002-07-20 Time 18:36 Rev Time 0.00
Received By kstevens Date 2002-07-20 Time 18:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-08 Cont ID  
Sent By kstevens Date 2002-06-08 Time 08:17 Rev Time 0.00
Received By kstevens Date 2002-06-08 Time 08:17 Sent To E
Notes
2002-06-08 00:00:00DENIED
 REFERENCE FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 3) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 4) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-23 Cont ID  
Sent By sgraham Date 2002-05-23 Time 11:44 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***