Plan Review Details - Permit 02051132
Plan Review Stops For Permit 02051132
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-06 Cont ID  
Sent By btrobaug Date 2002-06-06 Time 12:19 Rev Time 0.00
Received By btrobaug Date 2002-06-06 Time 11:47 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-09-09 Cont ID  
Sent By pkrauss Date 2002-09-09 Time 14:22 Rev Time 0.25
Received By pkrauss Date 2002-09-09 Time 14:15 Sent To  
Notes
2002-09-09 00:00:00MECH PERMTI 02051142

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-05 Cont ID  
Sent By pkrauss Date 2002-06-05 Time 14:37 Rev Time 0.35
Received By pkrauss Date 2002-06-05 Time 14:36 Sent To  
Notes
2002-06-05 00:00:00PROVISO:MECHANICAL PERMIT 02051142
  
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTORS
 WITH NOTIFICATION TO ALARM/STOBE OR AREA
 SMOKE DETECTORS. 2001 FBC(M) 606.4.1
  
 CONDENSATE SHALL DISCHARGE A MINIMUM OF
 12" AWAY FROM THE BUILDING STRUCTURE AS
 PER 2001 FBC 1503.4.4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-06-01 Cont ID  
Sent By jleech Date 2002-06-01 Time 10:57 Rev Time 0.33
Received By jleech Date 2002-06-01 Time 10:57 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-14 Cont ID  
Sent By rmcdouga Date 2002-08-14 Time 10:19 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-14 00:00:00PRODUCT APPROVALS FOR ROOF AND ARCH TOP
 WINDOW AS REQUIRED IN BUILDING PROVISO
 WERE SUBMITTED 8-14-02.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-06-18 Cont ID  
Sent By btrobaug Date 2002-06-06 Time 12:19 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-06-18 00:00:00************BUILDING PROVISO************
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - ROOF COVERING
 - ARCH TOP FIXED GLASS WINDOW
  
 2) STRUCTURE IS LOCATED IN AN "AO" FLOOD
 ZONE AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 NOTE: TRUSS DRAWINGS ARE NO LONGER
 REQUIRED TO BE SUBMITTED FOR PLAN REVIEW
 THE FIELD INSPECTOR WILL REVIEW THEM AT
 TRUSS INSPECTION AND BRING IN A SIGNED
 AND SEALED SET FOR THE FILE.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-23 Cont ID  
Sent By sgraham Date 2002-05-23 Time 11:40 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***