Plan Review Details - Permit 02051077
Plan Review Stops For Permit 02051077
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-07-17 Cont ID  
Sent By jwitmer Date 2002-07-17 Time 11:31 Rev Time 1.00
Received By jwitmer Date 2002-07-17 Time 11:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-06-11 Cont ID  
Sent By kstevens Date 2002-06-07 Time 18:50 Rev Time 0.00
Received By btrobaug Date 2002-06-11 Time 07:11 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-10 Cont ID  
Sent By kstevens Date 2002-06-07 Time 18:54 Rev Time 0.25
Received By ndenmark Date 2002-06-10 Time 06:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-07-16 Cont ID  
Sent By pschmitz Date 2002-07-16 Time 11:37 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-07-16 00:00:00PLUMBING PLAN REVIEW,REVISION,APPR.PES

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-06-07 Cont ID  
Sent By kstevens Date 2002-06-07 Time 18:50 Rev Time 0.00
Received By kstevens Date 2002-06-07 Time 18:49 Sent To M
Notes
2002-06-07 00:00:00DENIED
 REFERENCE: FBC-2001
  
 1) TRAP FROM SHOWER NOT VENTED PROPERLY.
 MAXIMUM DISTANCE OF FIXTURE TRAP FROM
 VENT IS 6 FEET. TABLE 906.1
 2) PLEASE SUBMIT RISER DIAGRAM THAT
 MEETS CODE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-09-09 Cont ID  
Sent By lmartine Date 2002-09-09 Time 15:59 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2002-09-09 00:00:00PASSED REVIEW FOR JIM WITMER

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-06-11 Cont ID  
Sent By btrobaug Date 2002-06-11 Time 07:37 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-06-11 00:00:00 
  
 BUILDING PLAN REVIEW
 PERMIT: 02051077
 ADD: 217 GREENWOOD DR
 CONT: REGIONAL CONSTRUCTION
 TEL: (954)545-1419
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
 A)WINDOWS
 B)STORM SHUTTERS
 C)ROOF ASSEMBLIES
  
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 2) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.
  
 ANY QUESTIONS PLEASE CALL,
 JIM WITMER
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8412

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-21 Cont ID  
Sent By sgraham Date 2002-05-21 Time 12:37 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***