Plan Review Stops For Permit 02050441 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-01-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-01-03 |
Time |
13:46 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2003-01-03 |
Time |
13:46 |
Sent To |
|
|
Notes |
2003-01-03 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 02050441 | | ADD: 3001 OKEECHOBEE BLVD | | CONT: POPPER & ASSOC | | TEL: (561)719-7133 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | REVISION : #2 12-03-02 | | ******BUILDING PROVISO****** | | 11-4.1.3(1) AT LEAST ONE ACCESSIBLE | | ROUTE COMPLYING WITH 11-4.3 SHALL | | CONNECT ACCESSIBLE BUILDING OR FACILITY | | ENETRANCES WITH ALL ACCESSIBLE SPACES | | AND ELEMENTS WITHIN THE BUILDING OR | | FACILITY. | | BUILDING PLAN REVIEW | | JIM WITMER |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2002-05-22 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2002-05-22 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-12-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-24 |
Time |
05:32 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-24 |
Time |
05:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2002-05-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-05-21 |
Time |
20:29 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-05-21 |
Time |
20:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2002-06-19 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2002-06-19 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-01-02 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-01-02 |
Time |
18:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2002-06-18 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-06-18 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-06-18 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-12-04 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-12-04 |
Time |
15:51 |
Sent To |
|
|
Notes |
2002-12-04 00:00:00 | TO COMM BOARD #64./WRT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2002-12-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-12-18 |
Time |
14:55 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2002-12-18 |
Time |
14:46 |
Sent To |
|
|
Notes |
2002-12-18 00:00:00 | PROVISO: MECHANICAL PERMIT 02050442 | | | | PLEASE NOTE AS PER 2001 FBC(M) 306.5, | | WHERE EQUIPMENT REQUIRING ACCESS ARE | | INSTALLED ON ROOFS AT A HEIGHT EXCEEDING | | 16 FT, SUCH ACCESS SHALL BE PROVIDED BY | | A PERMANENT APPROVED MEANS OF ACCESS. | | SUCH ACCESS SHALL NOT REQUIRE CLIMBING | | OVER OBSTRUCTIONS GREATER THAN 30". | | | | CONDENSER UNIT STANDS LOCATED OF THE | | ROOF SHALL COMPLY WITH 2001 FBC(M) | | 1511.7. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-06-25 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-06-25 |
Time |
09:29 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2002-06-25 |
Time |
09:24 |
Sent To |
|
|
Notes |
2002-06-25 00:00:00 | MECHANICAL PERMIT 02050442 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-06-03 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2002-06-03 |
Time |
14:00 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2002-06-03 |
Time |
14:00 |
Sent To |
|
|
Notes |
2002-06-03 00:00:00 | DENIED | | | | 1. EXHAUST AIR EQUALS 1000 CFM AND | | OUTSIDE AIR EQUALS 240 CFM WHICH HAS | | THIS BUILDING APPARENTLY 760 CFM | | NEGATIVE. PROVIDE INFORMATION ON WHERE | | ADDITIONAL OUTSIDE AIR IS FROM TO AVOID | | NEGATIVE PRESSURE ON BUILDING. | | | | 2. FAN SHUT DOWN BY DUCT SMOKE DETECTOR | | REQUIRED FOR AHU, WITH NOTIFICATION BY | | BUILDING ALARM SYSTEM. | | | | 3. NOTE: AHU LOCATION SHALL BE IN | | RESPECT TO BUILDING CONSTRUCTION TO | | ALLOW FOR SERVICE AND REPLACEMENT OF | | EQUIPMENT WITHOUT RESTRICTION OR | | REMOVAL OF BUILDING COMPONENTS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-12-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-12-27 |
Time |
14:16 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2002-12-27 |
Time |
14:16 |
Sent To |
|
|
Notes |
2002-12-27 00:00:00 | PASSED/PROVISO | | | | DEMO SUBJECT TO FIELD INSPECTOR'S | | APPROVAL WITH RESPECT TO JOB CONDITIONS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-06-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-06-04 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2002-06-04 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2002-06-19 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2002-06-19 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|