Plan Review Details - Permit 02050431
Plan Review Stops For Permit 02050431
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By hpiskura Date 2002-09-04 Time 15:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-05-24 Cont ID  
Sent By hpiskura Date 2002-05-24 Time 11:42 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-08-28 Cont ID  
Sent By dpalmer Date 2002-08-28 Time 19:39 Rev Time 0.25
Received By dpalmer Date 2002-08-28 Time 19:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-25 Cont ID  
Sent By dpalmer Date 2002-06-25 Time 17:55 Rev Time 0.00
Received By dpalmer Date 2002-06-25 Time 17:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-05-21 Cont ID  
Sent By dpalmer Date 2002-05-21 Time 18:49 Rev Time 0.00
Received By dpalmer Date 2002-05-21 Time 18:49 Sent To  
Notes
2002-05-21 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE NOTE CIRCUITS ON RISER
 FOR NEW 9,11,13,15 ARE COMING FROM A
 277/480 PANEL?? RECEPTS? 277V?
 PLEASE CLARIFY.
  
 2 )NOTE: PLEASE NOTE THAT THE LOAD
 CALCULATIONS NEED TO BE SHOWN. SQ FT/
 RECEPT LOADS ETC. PER 220-3,220-10,
 220-11, 220-13. (215-5)
  
 3) NOTE: PLEASE SHOW ALL CONTINUOUS AT
 125%. (LIGHTING ETC)
 215-2,215-3,230-42
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-09-05 Cont ID  
Sent By mcarsill Date 2002-09-05 Time 11:23 Rev Time 0.00
Received By mcarsill Date 2002-09-05 Time 11:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-06-19 Cont ID  
Sent By mcarsill Date 2002-06-19 Time 10:56 Rev Time 0.00
Received By mcarsill Date 2002-06-19 Time 10:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-09-12 Cont ID  
Sent By pkrauss Date 2002-09-12 Time 08:38 Rev Time 0.35
Received By pkrauss Date 2002-09-12 Time 08:14 Sent To  
Notes
2002-09-12 00:00:00MECHANICAL PERMIT 02050432

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-05-31 Cont ID  
Sent By pkrauss Date 2002-05-31 Time 14:17 Rev Time 0.40
Received By pkrauss Date 2002-05-31 Time 14:17 Sent To  
Notes
2002-05-31 00:00:00MECHANICAL PERMIT 02050432

Review Stop P PLUMBING
Rev No 2 Status N Date 2002-09-23 Cont ID  
Sent By kstevens Date 2002-09-23 Time 08:47 Rev Time 0.00
Received By kstevens Date 2002-09-23 Time 08:47 Sent To  
Notes
2002-09-23 00:00:00NO PLUMBING ON REVISION - DELEATED SINK
 D.F. IN COMMON AREA.

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-09-09 Cont ID  
Sent By kstevens Date 2002-09-09 Time 17:23 Rev Time 0.00
Received By kstevens Date 2002-09-09 Time 17:23 Sent To  
Notes
2002-09-09 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) SANITARY AND WATER RISER REQUIRED FOR
 SINK.
 2) SINK SHALL COMPLY WITH 11-4.24 AND
 ALL SUBSECTIONS. (HEIGHT-CLEAR FLOOR
 SPACE-ECT)
 3) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. (ALSO SEE SEC 410.1)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377