Plan Review Details - Permit 02050210
Plan Review Stops For Permit 02050210
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-05-28 Cont ID  
Sent By btrobaug Date 2002-05-28 Time 17:27 Rev Time 0.00
Received By btrobaug Date 2002-05-28 Time 17:19 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-08 Cont ID  
Sent By hmoser Date 2002-06-08 Time 07:11 Rev Time 0.50
Received By hmoser Date 2002-06-08 Time 07:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-05-27 Cont ID  
Sent By hmoser Date 2002-05-27 Time 12:27 Rev Time 0.50
Received By hmoser Date 2002-05-27 Time 12:27 Sent To  
Notes
2002-05-27 00:00:00PLAN DENIED
 1) MANUAL J DO NOT MATCH PLANS(CFM.)
 2) VARIFY TYPE OF VENTILATION USED FOR
 FRESH AIR NATURAL 402 OR MECHANICAL
 403
 3) NEED FAN SHUTDOWN AT FINAL INSPECTION
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-05-25 Cont ID  
Sent By kstevens Date 2002-05-25 Time 05:25 Rev Time 0.00
Received By kstevens Date 2002-05-25 Time 05:25 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-19 Cont ID  
Sent By rmcdouga Date 2002-08-19 Time 08:49 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-19 00:00:00REVISION FOR DOOR BUCKS OK 8-19-02

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-06-05 Cont ID  
Sent By btrobaug Date 2002-05-28 Time 17:28 Rev Time 2.50
Received By jgomez Date 2002-06-05 Time 16:45 Sent To  
Notes
2002-06-05 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-REVISE STRUCTURAL BUCK DETAIL TO
 COMPLY WITH REQUIREMENTS OF SECTION
 1707.4.4.2 FBC 2001 (BUCK SHALL EXTEND
 BEYOND THE INTERIOR FACE OF THE WINDOW
 OR DOOR FRAME).

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-16 Cont ID  
Sent By sgraham Date 2002-05-16 Time 09:28 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***