Plan Review Details - Permit 02041956
Plan Review Stops For Permit 02041956
Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-02-18 Cont ID  
Sent By btrobaug Date 2003-02-18 Time 16:58 Rev Time 0.50
Received By btrobaug Date 2003-02-18 Time 16:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-10-03 Cont ID  
Sent By btrobaug Date 2002-10-03 Time 14:48 Rev Time 0.25
Received By btrobaug Date 2002-10-03 Time 14:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-09-10 Cont ID  
Sent By btrobaug Date 2002-09-10 Time 11:00 Rev Time 0.50
Received By btrobaug Date 2002-09-10 Time 10:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-09 Cont ID  
Sent By btrobaug Date 2002-08-09 Time 17:27 Rev Time 0.00
Received By jwitmer Date 2002-08-10 Time 14:56 Sent To R
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-05-20 Cont ID  
Sent By btrobaug Date 2002-05-20 Time 09:57 Rev Time 0.00
Received By btrobaug Date 2002-05-20 Time 09:53 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 17:57 Rev Time 0.00
Received By dpalmer Date 2003-02-06 Time 17:57 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-21 Cont ID  
Sent By btrobaug Date 2002-11-21 Time 18:02 Rev Time 0.00
Received By btrobaug Date 2002-11-21 Time 18:02 Sent To M
Notes
2002-11-21 00:00:00IN BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-02-14 Cont ID  
Sent By pkrauss Date 2003-02-14 Time 16:21 Rev Time 0.25
Received By pkrauss Date 2003-02-14 Time 16:20 Sent To  
Notes
2003-02-14 00:00:00MECHANICAL PERMIT 02081243
 REVISED ENERGY CALCS - 12 SEER

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-07-20 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 17:57 Rev Time 0.33
Received By hmoser Date 2002-07-20 Time 11:42 Sent To  
Notes
2002-07-20 00:00:00PASS/PROVISO
 1) NEED MODEL NUMBER OF EVAPORITOR COIL
 2) NEED PROGRAMMABLE T.STAT FOR FINAL
 PLAN REVIEW BY HAROLD MOSER 7/20/02

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-05-16 Cont ID  
Sent By hmoser Date 2002-05-16 Time 15:28 Rev Time 0.33
Received By hmoser Date 2002-05-16 Time 15:28 Sent To  
Notes
2002-05-16 00:00:00PLAN DENIED
 NO ENERGY CALCS OR MANUAL J
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-05-11 Cont ID  
Sent By jleech Date 2002-05-11 Time 08:51 Rev Time 0.33
Received By jleech Date 2002-05-11 Time 08:51 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-09-08 Cont ID  
Sent By jwitmer Date 2002-09-08 Time 16:28 Rev Time 0.15
Received By jwitmer Date 2002-09-08 Time 16:28 Sent To  
Notes
2002-09-08 00:00:00REVISION POT SHELVES 8/31/02

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-08-10 Cont ID  
Sent By jwitmer Date 2002-08-10 Time 14:56 Rev Time 1.00
Received By jwitmer Date 2002-08-10 Time 14:56 Sent To  
Notes
2002-08-10 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02041956
 ADD: LOT#47 SEC#5 RENAISSANCE
 "LIBERTY ISLES"
 CONT: HOME DYNAMICS
 TEL: (954)520- 1698
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PLEASE PROVIDE THE ORIGINAL PERMIT
 APPLICTION.
  
 2) PROVIDE COPIES OF BOTH BZ RECEIPTS,
 THE ORIGINAL & THE UPPED CALCULATED
 VALUE PLUS RADON.
  
 3) PROVIDE A RECORDED COPY OF NOTICE
 OF COMMENCMENT.
  
 4)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 5) ZERO LOT LINE "TABLE 600 ISSUE/
 GLASS BLOCK: MUST BE ONE HOUR RATED,
 PROVIDE PRODUCT INFORMATION INDICATING
 A FULL HOUR. NOT 45 MINUTE, THIS IS NOT
 AN OPENING PROTECTIVE, ZERO LOT LINE RE-
 QUIRES A FULL 1 HOUR RATING, PLEASE
 PROVIDE THIS INFORMATION BEFORE WINDOW
 BUCK INSPECTION.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-06-10 Cont ID  
Sent By btrobaug Date 2002-08-09 Time 17:27 Rev Time 3.00
Received By jwitmer Date 2002-06-10 Time 09:02 Sent To  
Notes
2002-06-10 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02041956
 ADD: LOT# 47 SEC.# 5 RENASSANCE
 CONT: HOME DYNAMICS CONST CORP
 TEL: (954)275-8569
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
  
 2)1804.1.3 THE BOTTOM OF THE FOUNDA-
 TION SHALL EXTEND NO LESS THAN 12"
 BELOW FINISH GRADE. SHEET A-4, TYPICAL
 WALL SEC NOTE 1821.1.1 IS FOR "HIGH WIND
 AREAS".
  
 3) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 THE REPORT SUBMITTED INDICATES ON PAGE
 9 "THE INFORMATION PROVIDED IN THIS
 REPORT IS NOT SUFFICIENT FOR A FINAL
 DESIGN OF THE FOUNDATION SYSTEM.
  
 4) SHEET A-1 BOTTOM RIGHT OF CENTER,
 DISSCREPAANCY, PLANS CONFORM TO 2001 FBC
 / ASCE 5-95, SHOULD READ 7-98.
  
 5) PLANS INDICATE CHANGES IN BLACK INK,
 QUESTIONABLE AS TO WHOS CHANGES THESE
 ARE, PRESSURE ZONES ARE ALSO ADDED WITH
 OUT ARCHITECTS INITIALS OR ACCOMPANYING
 SIGNED / SEALED LETTER.
  
 6) COPY OF ASSOCIATIONS COVENENT, ROOF
 LINE IS OVER ZERO-LOT LINE?
  
 7) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.MISSING REPORTS:
 A) ROOFING REPORT; PROVIDE CURRENT
 ROOFING ASSEMBLY REPORT.
 B) GARAGE DOOR, HIGHLIGHT WHICH MODEL
 C) FRONT ENTRY DOOR.
 D) GLASS BLOCK, TO BE 1 HOUR RATED!!!
 THE GLASS BLOCK IS LOCATED IN THE ZERO-
 LOT LINE SIDE WHICH REQUIRES A HOUR RAT-
 ING WITH NO OPENINGS.
 E) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 8)1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 9)1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
 SHEET A-4 DETAILS INDICATE A DIFFERENT
 METHOD OF ATTACHMENT THAN SPECIFIED BY
 THE PRODUCT APPROVAL CHECK ALL REPORTS
 VS DETAILS!
  
 10)FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
  
 11) SHEET A-2 ROOF FRAMING PLAN, DOES
 NOT PROVIDE THE MAGNITUDE OF FORCES THAT
 ARE TO BE RESISTED, VERTICAL, HORIZONTAL
 OR GRAVITY.
  
 12) TRUSS ANCHOR SCHEDULE NOT INCLUDED,
 INDICATE MANUFACTURER, AND MODEL, DELETE
 ALL NOTES OF SEMCO AND HUGHES, THESE
 MANUFACTURERS ARE NO LONGER IN BUSINESS.
  
 13) SHEET A-4 NO INDICATION AS TO WHAT
 TYPE OF LATH IS TO BE USED FOR THE
 STUCCO SOFFIT, FBC 2405.2.2:
 2504.2.2 INSTALLATION OF EXTERIOR
 LATHING AND FRAMING SHALL COMPLY WITH
 ASTM C-1063. IF RIB LATH IS TO BE USED
 ON HORIZONTAL WOOD FRAMING 2" STAPLES OR
 NAILS SHALL BE USED @ EVERY RIB.
  
 14) SHEET A-1 LOWER LEFT OF PAGE NOTE
 " TYPE III / UNPROTECTED" CORRECT.
  
 15)BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.
  
 16)PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 ANY QUESTIONS PLEASE CALL,
 JIM WITMER
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8412

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-03 Cont ID  
Sent By sgraham Date 2002-05-03 Time 14:11 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***