Plan Review Details - Permit 02041740
Plan Review Stops For Permit 02041740
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-06-18 Cont ID  
Sent By jwitmer Date 2002-06-18 Time 10:14 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-05-28 Cont ID  
Sent By btrobaug Date 2002-05-28 Time 07:08 Rev Time 0.00
Received By btrobaug Date 2002-05-28 Time 06:45 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-08-20 Cont ID  
Sent By ndenmark Date 2002-08-20 Time 15:09 Rev Time 0.25
Received By ndenmark Date 2002-08-20 Time 15:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-05-23 Cont ID  
Sent By hmoser Date 2002-05-23 Time 18:23 Rev Time 0.50
Received By hmoser Date 2002-05-23 Time 18:23 Sent To  
Notes
2002-05-23 00:00:00PROVISO
 #1 VERIFY TYPE OF VEVTILATION USED FOR
 FRESH AIR NATURAL 402 OR
 MECHANICAL 403
 #2 NEED CALCULATIONS FOR TYPE OF
 VENTILATION USED
 #3REFER TO SECTION 403 NO WINDOW
 EXCEPTION [BATHROOM]
 #4 CONDENSATE DRAIN MUST TERMINATE 12IN.
 FROM BUILDING
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-07-24 Cont ID  
Sent By kstevens Date 2002-07-24 Time 12:07 Rev Time 0.00
Received By kstevens Date 2002-07-24 Time 12:07 Sent To  
Notes
2002-07-24 00:00:00REVISION OK - SANT RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-05-23 Cont ID  
Sent By kstevens Date 2002-05-23 Time 17:43 Rev Time 0.00
Received By kstevens Date 2002-05-23 Time 17:43 Sent To  
Notes
2002-05-23 00:00:00PASSED/PROVISO
  
 SUBMIT SANITARY RISER DIAGRAM THAT RE-
 FLECTS FLOOR PLAN.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-06-18 Cont ID  
Sent By jwitmer Date 2002-06-18 Time 10:14 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-06-04 Cont ID  
Sent By btrobaug Date 2002-05-28 Time 07:08 Rev Time 2.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-06-04 00:00:00BUILDING PLAN REVIEW
 PERMIT:02041740
 ADD: 9574 LANTERN BAY CIR
 CONT: ENGLE HOMES
 TEL: 968-5671
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 *******BUILDING- FAILED*********
 FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
  
 2) PROVIDE PRODUCT TESTING REPORT FOR
 THE ROOFING ASSEMBLY BEFORE ROOF FRAMING
 INSPECTION.
  
 3) THE DESIGN PARAMETERS & ASSUMPTIONS
 ARE DESIGNED TO THE 1997 STANDARD BUILD-
 ING CODE NOT THE 2001 FLORIDA BUIULDING
 CODE.
  
 ANY QUESTIONS PLEASE CALL,
 JIM WITMER
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8412
 (561) 659-8096 EXT. 8412

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-15 Cont ID  
Sent By sgraham Date 2002-05-15 Time 08:52 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***