Plan Review Details - Permit 02041671
Plan Review Stops For Permit 02041671
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-07-09 Cont ID  
Sent By dpalmer Date 2002-07-09 Time 15:11 Rev Time 0.00
Received By dpalmer Date 2002-07-09 Time 15:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-05-15 Cont ID  
Sent By dpalmer Date 2002-05-15 Time 06:13 Rev Time 0.00
Received By dpalmer Date 2002-05-15 Time 06:13 Sent To B
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-07-16 Cont ID  
Sent By mcarsill Date 2002-07-16 Time 10:59 Rev Time 0.00
Received By mcarsill Date 2002-07-16 Time 10:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-06-14 Cont ID  
Sent By rmcdouga Date 2002-07-09 Time 10:34 Rev Time 0.00
Received By mcarsill Date 2002-06-14 Time 08:55 Sent To  
Notes
2002-06-14 00:00:001) PLANS DO NOT INDICATE LOCATIONS OF
 FIRE HYDRANT LOCATIONS.
  
 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
  
 3) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED.
  
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
  
 5) PLEASE CLEARLY INDICATE LOCATIONS
 OF ALL EGRESS WINDOWS.
  
 6) TENANT SEPARATIONS ARE TO COMPLY
 WITH APPLICABLE CODES.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-19 Cont ID  
Sent By pkrauss Date 2002-12-19 Time 11:21 Rev Time 0.20
Received By pkrauss Date 2002-12-19 Time 11:21 Sent To  
Notes
2002-12-19 00:00:00MECH PERMIT02080775
 REVISED ENERGY CALCS

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-07-06 Cont ID  
Sent By hmoser Date 2002-07-06 Time 09:13 Rev Time 0.50
Received By hmoser Date 2002-07-06 Time 09:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-05-11 Cont ID  
Sent By hmoser Date 2002-05-11 Time 08:09 Rev Time 0.33
Received By hmoser Date 2002-05-11 Time 08:09 Sent To  
Notes
2002-05-11 00:00:00PLAN DENIED
 #1 CFM.DON'T MATCH TOTAL CFM.ON PLAN
 #2 NO RETURN AIR DUCT SIZE
 #3 COMPLY WITH FRESH AIR REQUIREMENTS
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-12-18 Cont ID  
Sent By kstevens Date 2002-12-18 Time 08:34 Rev Time 0.10
Received By kstevens Date 2002-12-18 Time 08:34 Sent To  
Notes
2002-12-18 00:00:00SUBMITTAL LETTER - DELETE REQUIREMENT TO
 INSULATE HOT WATER PIPES.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-05-06 Cont ID  
Sent By jleech Date 2002-05-06 Time 20:13 Rev Time 0.33
Received By jleech Date 2002-05-06 Time 20:13 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-07-09 Cont ID  
Sent By rmcdouga Date 2002-07-09 Time 10:32 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To FIRE
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-06-10 Cont ID  
Sent By rmcdouga Date 2002-06-10 Time 18:06 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-06-10 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) THE AREA OF THE WALL OPENINGS AT THE
 FRONT ELEVATION EXCEEDS THE PERCENTAGE
 ALLOWED BY TABLE 600. THE CALCULATIONS
 ARE INCORRECT. THE PERCENTAGE ALLOWED IS
 20% FROM OVER 3 FEET TO 10 FEET AND IS
 40% FROM OVER 10 FEET TO 20 FEET. PLEASE
 CORRECT.
  
 3) THE 2001 FBC SECTION 1606.1.7
 REQUIRES THE FOLLOWING INFORMATION TO BE
 SHOWN ON THE CONSTRUCTION DRAWINGS:
 - BASIC WIND SPEED, MPH.
 - WIND IMPORTANCE FACTOR(1) AND BUILDING
 CATEGORY.
 - WIND EXPOSURE- IF MORE THAN ONE WIND
 EXPOSURE IS USED THE WIND EXPOSURE AND
 APPLICABLE WIND DIRECTION SHALL BE
 INDICATED.
 - THE APPLICABLE INTERNAL PRESSURE
 COEFFICIENT
 - COMPONENTS AND CLADDING. THE DESIGN
 WIND PRESSURES IN TERMS OF PSF, TO BE
 USED FOR THE DESIGN OF EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED
 DESIGN PROFESSIONAL.
 PLEASE UPDATE THE DESIGN INFORMATION ON
 S1.
  
 4) INDICATE THE POSITIVE AND NEGATIVE
 WINDLOAD PRESSURES FOR THE SKYLIGHT AND
 THE 25 SH WINDOW IN THE GARAGE.
  
 5) REVISE NOTE #2 ON A1 TO REFERENCE THE
 FLORIDA BUILDING CODE.
  
 6) REVISE THE BUCK DETAIL #2 ON A4 TO
 COMPLY WITH FBC SEC. 1707.4.4.2.
  
 7) PLEASE UPDATE THE FOLLOWING NOTES ON
 S4 TO REFERENCE THE 2001 FBC:
 - #3 & #4 UNDER GENERAL NOTES
 - #9 UNDER GENERAL NOTES TO ASCE 7-98 &
 140 MPH (3 SEC. GUST)
 - #1 UNDER SAFEGUARDS
 - #1 UNDER REINFORCED CONCRETE
 - #2 UNDER TRUSSES
 - #5 UNDER ROOF SHEATHING
  
 8) PLEASE REVISE NOTE #7, THE CORRECT
 REFERENCE IS ASTM A 185. THE WELDED WIRE
 FABRIC IS REQUIRED TO BE SUPPORTED PER
 FBC SEC. 1909.3.
  
 9) THE NEGATIVE PRESSURE FOR THE 1/2- 36
 SH KDI WINDOWS IN THE DEN AND LIVING
 ROOM EXCEED THE VALUE IN THE SBCCI
 PRODUCT EVALUATION REPORT. THE
 COMPARATIVE ANALYSIS REPORT SUBMITTED IS
 NOT VALID UNLESS IT IS AN ORIGINAL
 SIGNED AND SEALED COPY.
  
 10) PLEASE SUBMIT KEY PLANS AND
 INSTALLATION SCHEDULE FOR THIS MODEL.
  
 11) THE PRODUCT APPROVAL FOR ENTEGRA
 ROOF TILE IS EXPIRED.
  
 12) PROVIDE THE CORRECT GARAGE DOOR
 DRAWING. THE ONE ATTACHED TO THE PRODUCT
 APPROVAL IS FOR A 9 FOOT DOOR.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-05 Cont ID  
Sent By sgraham Date 2002-06-05 Time 09:40 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***