Plan Review Stops For Permit 02041630 |
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2002-08-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-08-06 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-08-06 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2002-07-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-07-23 |
Time |
06:46 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-07-23 |
Time |
06:46 |
Sent To |
B |
|
Notes |
2002-07-23 00:00:00 | ****************** UNSAT ************** | | | | ********** NOTE ************ | | 3RD TIME UNSAT, PLEASE SEE ATTACHED | | SHEET FOR FS.553.802B. PLANS BEING SENT | | BACK FOR THE SAME COMMENTS. | | PLEASE SEE ATTACHED SHEETS FOR PREVIOUS | | TWO REVIEWS AND COMMENTS. | | | | 1)NOTE: PLEASE NOTE AN EQUIPMENT GROUND- | | -ING CONDUCTOR IS STILL BEING SHOWN | | BETWEEN METER AND MAIN?? THIS IS PARA- | | LLELING THE NEUTRAL WHICH IS NOT | | PERMITTED. PLEASE NOTE THAT THE NEUTRAL | | IS BONDED WITH THE GRND SCREW AT THE | | FIRST MEANS OF DISC. | | | | 2)NOTE: PLEASE NOTE THAT THE TWO SMALL | | APPLIANCE CIRCUITS REQ`D PER 210-52B | | 210-11-C-1 ARE STILL NOT SHOWN IN LOAD | | CALCULATIONS?? PLEASE NOTE MICROWAVE IS | | SHOWN ON LOAD CALCS BUT NOT PANEL | | SCHEDULE? | | | | 3)NOTE: PLEASE VERIFY LOAD SHOWN FOR | | RANGE AT 5KW? | | | | 4)NOTE: PLEASE NOTE SD IS SHOWN IN BATH, | | SD`S ARE NOT PERMITTED IN BATHS PER | | NFPA-72, 2-5.2.1.6 | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW AND | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 | | | | | | BILL TROBAUGH | | X-8392 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2002-07-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-07-09 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-07-09 |
Time |
06:37 |
Sent To |
FIRE |
|
Notes |
2002-07-09 00:00:00 | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE NOTE THE FOLLOWING | | DISCREPANCIES,CORRECT PLANS AND | | RESUBMIT FOR REVIEW: | | | | 1} RISER STILL HAS THE EQUIPMENT GROUND | | FROM THE METER TO THE DISCONNECT.PLEASE | | REMOVE. | | | | 2} THE SMALL APPLIANCE CIRCUITS NEED TO | | BE INCLUDED IN THE LOAD CALCULATIONS AS | | INDICATED ON THE PREVIOUS REVIEW. | | | | 3} SHEET E-1.0 HAS AN ARCHITECTURAL | | TITLE BLOCK BUT IS NOT SEALED PER | | 61G1-16.001 FAC. | | | | | | IF THERE ARE ANY QUESTION PLEASE CALL: | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | 561/659-8096 EXT. 8392 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-05-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-05-15 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2002-05-15 |
Time |
15:07 |
Sent To |
R |
|
Notes |
2002-05-15 00:00:00 | ~~~~~~~~~~~~~~~~~UNSAT!~~~~~~~~~~~~~~~~~ | | PLEASE NOTE THE FOLLOWING | | DISCREPANCIES,CORRECT PLANS AND | | RESUBMIT FOR REVIEW. | | | | 1} THE RISER DIAGRAM INDICATES THE | | EQUIPMENT GROUND BEING RAN FROM THE | | METER TO THE DISCONNECT.PLEASE REMOVE | | SAME TO AVOID A PARALLEL GROUND/NEUTRAL | | PATH. | | | | 2} INCLUDE SMALL APPLIANCE CIRCUITS IN | | LOAD CALC. PER 220-30. | | | | 3} PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CIRCUITS ON PANEL | | SCHEDULE. PER 210-12 | | | | 4} LIST KITCHEN CIRCUITS ON PANEL | | SCHEDULE. | | | | 5} A/C #1 AHU @ 10K,BREAKER AND BRANCH | | CIRCUIT CONDUCTORS ARE UNDERSIZED. | | | | 6} THE WASHER IS LISTED AT 3000W IN THE | | LOAD CALCS AND SHOWN ON A 20 AMP BREAKER | | WITH #12 WIRE ON THE PANEL SCHEDULE, | | PLEASE CLARIFY. | | | | 7} OVEN SHOWN ON PANEL SCHEDULE, BUT NOT | | IN LOAD CALCS,PLEASE CLARIFY. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/659-8096 EXT. 8392 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2002-07-16 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2002-07-16 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-07-16 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2002-06-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-07-10 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2002-06-13 |
Time |
14:26 |
Sent To |
|
|
Notes |
2002-06-13 00:00:00 | 1) PLEASE CLEARLY INDICATE LOCATIONS | | OF FIRE HYDRANTS FOR THE DEVELOPMENT. | | | | 2) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | | 3) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | TO,DURING AND AFTER CONSTRUCTION. | | | | 4) ANY ROADS MORE THAN 150 FEET ARE | | REQUIRED TO HAVE APPROVED TURN-AROUNDS | | AT 50 FEET OF CENTERLINE. | | | | 5) ELECTRIC POWERED SMOKE DETECTORS | | ARE REQUIRED. | | | | 6) TENANT SEPARATIONS ARE REQUIRED. | | | | 7) PLEASE CLEARLY IDENTIFY ALL EGRESS | | WINDOWS. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-12-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-12-18 |
Time |
16:28 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2002-12-18 |
Time |
16:28 |
Sent To |
|
|
Notes |
2002-12-18 00:00:00 | MECH PERMIT 02041634 | | REVISED ENERGY CALCS |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2002-05-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-05-11 |
Time |
11:40 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2002-05-11 |
Time |
11:40 |
Sent To |
|
|
Notes |
2002-05-11 00:00:00 | PROVISO | | SHOW TYPE OF VENTILATION USED. | | NEED CALCULATIONS FOR TYPE OF | | VANTILATION USED | | HAROLD MOSER [561]659-8096 EXE 8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-12-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-12-18 |
Time |
08:00 |
Rev Time |
0.10 |
Received By |
kstevens |
Date |
2002-12-18 |
Time |
07:59 |
Sent To |
|
|
Notes |
2002-12-18 00:00:00 | SUBMITTAL LETTER - DELETE REQUIREMENT TO | | INSULATE HOT WATER PIPE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-05-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2002-05-08 |
Time |
18:22 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-05-08 |
Time |
18:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2002-07-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-07-25 |
Time |
13:52 |
Rev Time |
1.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-07-25 00:00:00 | ************BUILDING PROVISO************ | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 2) PLEASE REVISE THE ORIGINAL MYLAR TO | | CORRECT THE INFORMATION FOR THE SPACING | | OF SUPPORTS FOR THE WELDED WIRE MESH. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2002-07-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-07-10 |
Time |
11:35 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
FIRE |
|
Notes |
2002-07-10 00:00:00 | BUILDING DENIED | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 2) THE NEGATIVE WINDLOAD PRESSURE GIVEN | | ON THE PLANS (-118.40 PSF ) FOR THE 1/2 | | 33SH BATHROOM WINDOW,EXCEEDS THE MAXIMUM | | NEGATIVE DESIGN PRESSURE LISTED IN THE | | KDI WINDOW COMPARATIVE ANALYSIS CHART | | FOR THAT SIZE WINDOW (-109 PSF). | | PLEASE CORRECT. | | | | 3) THE MAXIMUM SPACING FOR WELDED WIRE | | MESH SUPPORTS SHALL NOT EXCEED 3 FEET OR | | MANUFACTURERS' SPECIFICATIONS PER FBC | | SECTION 1909.3 (2). PLEASE REVISE THE | | NOTES ON SHEETS S1 AND S4 TO REFLECT | | THIS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2002-06-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2002-07-09 |
Time |
14:33 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-06-04 00:00:00 | BUILDING DENIED | | | | SAME COMMENTS AS PERMIT # 02041683. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-06-05 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-06-05 |
Time |
08:40 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|