Plan Review Details - Permit 02040977
Plan Review Stops For Permit 02040977
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-01-08 Cont ID  
Sent By lhatten Date 2003-01-08 Time 08:24 Rev Time 1.00
Received By lhatten Date 2003-01-07 Time 08:22 Sent To  
Notes
2003-01-08 00:00:00REVIEW & RESTAMPED PLANS 01/07/2003
 TIME FOR DOCUMENTATION OF THIS ACTIVITY

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-06-19 Cont ID  
Sent By lhatten Date 2002-06-19 Time 18:49 Rev Time 2.50
Received By lhatten Date 2002-06-18 Time 18:48 Sent To  
Notes
2002-06-19 00:00:00REVIEW & STAMPED PLANS06/18/2002

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-05-29 Cont ID  
Sent By drunnels Date 2002-05-29 Time 09:55 Rev Time 0.50
Received By drunnels Date   Time   Sent To  
Notes
2002-05-29 00:00:001. GENERAL NOTES STATES SLAB 3000 PSI &
 BEAM/COLUMN 4000 PSI, DETAILS SHOW SLAB
 2500 PSI & BEAM/COLUMN 3000 PSI
 2. MEAN ROOF HEIGHTS ON DESIGN PARAMETER
 DO NOT MATCH TRUSS SHEETS
  
 PER LOU HATTEN

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 10:35 Rev Time 0.25
Received By dpalmer Date 2002-12-23 Time 10:34 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-07 Cont ID  
Sent By dpalmer Date 2002-06-07 Time 15:27 Rev Time 0.00
Received By dpalmer Date 2002-06-07 Time 15:19 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-06-07 Cont ID  
Sent By drunnels Date 2002-05-29 Time 09:58 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2002-05-08 00:00:00****************** UNSAT *************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50. SIZE PER 250-66
  
 3) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 MISSING BED RM
  
 4)NOTE: PLEASE NOTE MISSING OUTLET FOR
 A/C EQUIPMENT. PER 210-63 AND/OR SECTION
 306 OF THE MECHANICAL CODE.
  
 5))NOTE: PLEASE LIST THE REQ`D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE. PER 210-12
  
 6)NOTE: PLEASE NOTE THAT PER LOCAL
 AMENDMENTS , ALL SERVICE ENTRANCE
 CONDUCTORS SHALL BE IN A RACEWAY AS
 SPECIFIED IN 230-43 OF THE LOCAL CODE.
 PLEASE ALSO NOTE NO ALUM CONDUCTORS OF
 ANY KIND SMALLER THAN #2 AND NONE FOR
 GROUNDING OR BONDING. 310-2
  
 7)NOTE: PLEASE NOTE THAT ELECTRICAL
 NOTES MENTIONS TO PLACE SD`S ON KITCHEN
 AND BATH CIRCUITS? PLEASE CLARIFY.
 LIGHTING?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 10:34 Rev Time 0.00
Received By dpalmer Date 2002-12-23 Time 10:34 Sent To E
Notes
2002-12-23 00:00:00TO TRADES FOR RE-STAMP.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-01-06 Cont ID  
Sent By pkrauss Date 2003-01-06 Time 16:54 Rev Time 0.15
Received By pkrauss Date 2003-01-06 Time 16:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-13 Cont ID  
Sent By kstevens Date 2003-01-06 Time 16:45 Rev Time 0.50
Received By hmoser Date 2002-06-13 Time 17:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-05-07 Cont ID  
Sent By hmoser Date 2002-05-07 Time 18:40 Rev Time 0.50
Received By hmoser Date 2002-05-07 Time 18:40 Sent To  
Notes
2002-05-07 00:00:00PLAN DENIED
 NO AIRCONDITIONING EQUIPMENT SCHEDULE
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-01-06 Cont ID  
Sent By kstevens Date 2003-01-06 Time 16:44 Rev Time 0.50
Received By kstevens Date 2003-01-06 Time 16:44 Sent To M
Notes
2003-01-06 00:00:00RESTAMP

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-06-08 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 10:34 Rev Time 0.33
Received By jleech Date 2002-06-08 Time 12:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-05-03 Cont ID  
Sent By kstevens Date 2002-05-03 Time 19:25 Rev Time 0.00
Received By aneil Date 2002-05-06 Time 13:12 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-04-26 Cont ID  
Sent By sgraham Date 2002-04-26 Time 14:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***