Plan Review Stops For Permit 02040977 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-01-08 |
|
|
Cont ID |
|
Sent By |
lhatten |
Date |
2003-01-08 |
Time |
08:24 |
Rev Time |
1.00 |
Received By |
lhatten |
Date |
2003-01-07 |
Time |
08:22 |
Sent To |
|
|
Notes |
2003-01-08 00:00:00 | REVIEW & RESTAMPED PLANS 01/07/2003 | | TIME FOR DOCUMENTATION OF THIS ACTIVITY |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2002-06-19 |
|
|
Cont ID |
|
Sent By |
lhatten |
Date |
2002-06-19 |
Time |
18:49 |
Rev Time |
2.50 |
Received By |
lhatten |
Date |
2002-06-18 |
Time |
18:48 |
Sent To |
|
|
Notes |
2002-06-19 00:00:00 | REVIEW & STAMPED PLANS06/18/2002 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2002-05-29 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2002-05-29 |
Time |
09:55 |
Rev Time |
0.50 |
Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-05-29 00:00:00 | 1. GENERAL NOTES STATES SLAB 3000 PSI & | | BEAM/COLUMN 4000 PSI, DETAILS SHOW SLAB | | 2500 PSI & BEAM/COLUMN 3000 PSI | | 2. MEAN ROOF HEIGHTS ON DESIGN PARAMETER | | DO NOT MATCH TRUSS SHEETS | | | | PER LOU HATTEN |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2002-12-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
10:35 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2002-12-23 |
Time |
10:34 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2002-06-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-06-07 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-06-07 |
Time |
15:19 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2002-06-07 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2002-05-29 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-05-08 00:00:00 | ****************** UNSAT ************* | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | 2) NOTE: PLEASE SHOW GROUNDING ELECTRODE | | GOING TO BUILDING STEEL AND COLD WATER | | PER 250-50. SIZE PER 250-66 | | | | 3) NOTE: PLEASE SHOW ALL OUTLET SPACING | | TO MEET 2`,6`,12` RULE PER 210-52. | | MISSING BED RM | | | | 4)NOTE: PLEASE NOTE MISSING OUTLET FOR | | A/C EQUIPMENT. PER 210-63 AND/OR SECTION | | 306 OF THE MECHANICAL CODE. | | | | 5))NOTE: PLEASE LIST THE REQ`D ARC | | FAULT PROTECTED CIRCUITS ON PANEL | | SCHEDULE. PER 210-12 | | | | 6)NOTE: PLEASE NOTE THAT PER LOCAL | | AMENDMENTS , ALL SERVICE ENTRANCE | | CONDUCTORS SHALL BE IN A RACEWAY AS | | SPECIFIED IN 230-43 OF THE LOCAL CODE. | | PLEASE ALSO NOTE NO ALUM CONDUCTORS OF | | ANY KIND SMALLER THAN #2 AND NONE FOR | | GROUNDING OR BONDING. 310-2 | | | | 7)NOTE: PLEASE NOTE THAT ELECTRICAL | | NOTES MENTIONS TO PLACE SD`S ON KITCHEN | | AND BATH CIRCUITS? PLEASE CLARIFY. | | LIGHTING? | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2002-12-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2002-12-23 |
Time |
10:34 |
Sent To |
E |
|
Notes |
2002-12-23 00:00:00 | TO TRADES FOR RE-STAMP. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2003-01-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-01-06 |
Time |
16:54 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2003-01-06 |
Time |
16:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2002-06-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-06 |
Time |
16:45 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2002-06-13 |
Time |
17:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2002-05-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2002-05-07 |
Time |
18:40 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2002-05-07 |
Time |
18:40 |
Sent To |
|
|
Notes |
2002-05-07 00:00:00 | PLAN DENIED | | NO AIRCONDITIONING EQUIPMENT SCHEDULE | | PLAN REVIEW BY HAROLD MOSER | | [561]659-8096 EXT 8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-01-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-01-06 |
Time |
16:44 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-01-06 |
Time |
16:44 |
Sent To |
M |
|
Notes |
2003-01-06 00:00:00 | RESTAMP |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2002-06-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
10:34 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2002-06-08 |
Time |
12:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2002-05-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-05-03 |
Time |
19:25 |
Rev Time |
0.00 |
Received By |
aneil |
Date |
2002-05-06 |
Time |
13:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2002-04-26 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2002-04-26 |
Time |
14:45 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|