Plan Review Details - Permit 02040974
Plan Review Stops For Permit 02040974
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-06-19 Cont ID  
Sent By lhatten Date 2002-06-19 Time 18:57 Rev Time 2.50
Received By lhatten Date 2002-06-18 Time 18:56 Sent To  
Notes
2002-06-19 00:00:00REVIEW & STAMPED PLANS 06/18/2002

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-05-29 Cont ID  
Sent By dpalmer Date 2002-05-08 Time 19:54 Rev Time 0.50
Received By drunnels Date   Time   Sent To  
Notes
2002-05-29 00:00:001. GENERAL NOTES STATES SLAB 4000 PSI &
 BEAM/COLUMN 3000 PSI, DETAILS SHOW SLAB
 2500 PSI & BEAM/COLUMN 3000 PSI
 2. MEAN ROOF HEIGHTS ON DESIGN PARAMETER
 DO NOT MATCH TRUSS SHEETS
  
 PER LOU HATTEN

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-12-04 Cont ID  
Sent By btrobaug Date 2002-12-04 Time 14:30 Rev Time 0.50
Received By btrobaug Date 2002-12-04 Time 14:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-07 Cont ID  
Sent By dpalmer Date 2002-06-07 Time 16:21 Rev Time 0.00
Received By dpalmer Date 2002-06-07 Time 15:56 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-05-08 Cont ID  
Sent By dpalmer Date 2002-05-08 Time 19:54 Rev Time 0.00
Received By dpalmer Date 2002-05-08 Time 19:54 Sent To B
Notes
2002-05-08 00:00:00************ UNSAT ******************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50. SIZE PER 250-66
  
 3)NOTE: PLEASE NOTE MISSING OUTLET FOR
 A/C EQUIPMENT. PER 210-63 AND/OR SECTION
 306 OF THE MECHANICAL CODE.
  
 4))NOTE: PLEASE CLARIFY EQUIPMENT
 GROUNDING METHOD BETWEEN FIRST MEANS
 OF DISCONNECT AND PANELS. PLEASE SIZE
 CONDUCTORS PER 250-122.
  
 5))NOTE: PLEASE LIST THE REQ`D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE. PER 210-12
  
 6)NOTE: PLEASE NOTE THAT PER LOCAL
 AMENDMENTS, ALL SERVICE ENTRANCE
 CONDUCTORS SHALL BE IN A RACEWAY AS
 SPECIFIED IN 230-43 OF THE LOCAL CODE.
 PLEASE ALSO NOTE NO ALUM CONDUCTORS
 OF ANY KIND SMALLER THAN #2 AND NONE
 USED FOR GROUNDING OR BONDING. 310-2
  
 7)NOTE: PLEASE NOTE THAT ELECTRICAL
 NOTES MENTIONS TO PLACE SD`S ON BATH
 AND KITCHEN CIRCUITS? PLEASE CLARIFY,,
 LIGHTING?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
  
  
 8)NOTE: PLEASE NOTE MISSING HALLWAY REC
 MASTER BR. 210-52H

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-13 Cont ID  
Sent By hmoser Date 2002-06-13 Time 17:46 Rev Time 0.50
Received By hmoser Date 2002-06-13 Time 17:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-05-07 Cont ID  
Sent By hmoser Date 2002-05-07 Time 19:31 Rev Time 0.50
Received By hmoser Date 2002-05-07 Time 19:31 Sent To  
Notes
2002-05-07 00:00:00PLAN DENIED
 NO AIRCONDITIONING EQUIPMENT SCHEDULE.
 MAIN TRUNK LINE OFF 12X12 DUCT NOT
 MARKED[SIZE]2ED FLOOR
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-06-08 Cont ID  
Sent By dpalmer Date 2002-06-07 Time 16:21 Rev Time 0.33
Received By jleech Date 2002-06-08 Time 12:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-05-03 Cont ID  
Sent By kstevens Date 2002-05-03 Time 19:39 Rev Time 0.00
Received By aneil Date 2002-05-06 Time 13:15 Sent To  
Notes
2002-05-03 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT S-1, SANITARY RISER DIAGRAM DOES
 NOT MATCH FLOOR PLAN.
 2) WASH MACHINE NOT SHOWN ON RISER DIA.
 3) MASTER BATH SHOWN WITH LAVS, TUB, &
 SHOWER LAID OUT RIGHT TO LEFT IN HOUSE
 AND SHOWN BACK TO FRONT ON FLOOR PLAN.
 3) BATHROOMS SHALL BE LAID OUT THE SAME
 ON RISER DIAG. AS FLOOR PLAN. LAV TO
 RIGHT OF W/C AT BDRM #2 NOT ON SAME SIDE
 AS TUB.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-04-26 Cont ID  
Sent By sgraham Date 2002-04-26 Time 15:15 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***