Plan Review Details - Permit 02040130
Plan Review Stops For Permit 02040130
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-04-26 Cont ID  
Sent By lsmith Date 2002-04-26 Time 16:51 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-04-22 Cont ID  
Sent By kstevens Date 2002-04-21 Time 18:07 Rev Time 0.00
Received By btrobaug Date 2002-04-22 Time 17:04 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-05-01 Cont ID  
Sent By kstevens Date 2002-05-01 Time 09:29 Rev Time 0.00
Received By kstevens Date 2002-05-01 Time 09:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-04-21 Cont ID  
Sent By kstevens Date 2002-04-21 Time 18:01 Rev Time 0.00
Received By kstevens Date 2002-04-21 Time 18:00 Sent To E
Notes
2002-04-21 00:00:00DENIED
 REFERENCE: FBC-2001 SEC 424.2 PRIVATE
 POOLS
  
 1) PLEASE ADJUST NOTES AND DETAILS FOR
 POOL PLANS FOR REVIEW.
 A)
 FBC-2001 SEC 424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 B)
 FBC-2001 SEC 424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE FIL-
 TER. (DETAIL)
 C)
 FBC-2001 SEC 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 2) PLEASE SUBMIT AN ISOMETRIC FOR THE
 POOL EQUIPMENT AND PIPING. INDICATE PIPE
 SIZES, VALVES, VENTS, BYPASSES AND RE-
 LATED PUMPS, FILTERS, HEATER EXT.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-04-23 Cont ID  
Sent By btrobaug Date 2002-04-22 Time 17:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***